  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-08-13",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "48091",
      "product_res_number": "Z-0412-2007",
      "event_date_initiated": "2004-09-24",
      "event_date_posted": "2007-02-10",
      "recall_status": "Terminated",
      "event_date_terminated": "2008-04-18",
      "res_event_number": "36154",
      "product_code": "DSQ",
      "pma_numbers": [
        "P870072"
      ],
      "product_description": "Thoratec Dual Drive Console a drive component of the Thoratec Ventricular Assist Device, Model Numbers, 10025-2600-005, 10025-2601-007, 10025-2602-006, Thoratec Corporation, 6035 Stoneridge Drive, Pleasanton, CA 94588",
      "code_info": "All Dual Drive Consoles manufactured before July 10, 2002 with serial numbers between 301 and 636, inclusive",
      "firm_fei_number": "2916596",
      "recalling_firm": "Thoratec  Corp",
      "address_1": "6035 Stoneridge Drive",
      "city": "Pleasanton",
      "state": "CA",
      "postal_code": "94588",
      "additional_info_contact": "Gary D. Cederwall\n925-730-4118",
      "reason_for_recall": "The module power switch (at the back of console) may break while attempting to turn the Dual Drive Console OFF or ON.",
      "root_cause_description": "Other",
      "action": "The firm issued on 1/25/07 an URGENT: MEDICAL DEVICE CORRECTION-notice informing its consignees about the 'Power Switch Replacement Instructions' and arrangements for their service department replacement of the switches.",
      "product_quantity": "331",
      "distribution_pattern": "Worldwide",
      "openfda": {
        "device_name": "Ventricular (Assist) Bypass",
        "medical_specialty_description": "Unknown",
        "regulation_number": "",
        "device_class": "3",
        "pma_number": [
          "P170038",
          "P920014",
          "P870072",
          "P160035",
          "P900023",
          "P100047",
          "P160054",
          "P980012",
          "P060040"
        ],
        "registration_number": [
          "2029275",
          "9612515",
          "3010163695",
          "1721676",
          "1218444",
          "3008454189",
          "2031044",
          "2134470",
          "1927395",
          "2916596",
          "3005228872",
          "3007042319",
          "3012931014",
          "3008792657",
          "1319639",
          "2528981",
          "2182208",
          "3019807891",
          "3002807090",
          "3011823740",
          "3004582654",
          "2133810",
          "3003306248"
        ],
        "fei_number": [
          "3001236763",
          "1000138054",
          "3010163695",
          "1721676",
          "1218444",
          "3000203066",
          "3008454189",
          "1927395",
          "2916596",
          "1000306431",
          "3005228872",
          "3007042319",
          "3012931014",
          "3008792657",
          "2528981",
          "3002462840",
          "2182208",
          "3019807891",
          "3011823740",
          "3004582654",
          "3002808437",
          "3006003617",
          "3003306248"
        ]
      }
    }
  ]
}