{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-08-20",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "43341",
      "product_res_number": "Z-0579-06",
      "event_date_initiated": "2005-12-21",
      "event_date_posted": "2006-03-01",
      "recall_status": "Terminated",
      "event_date_terminated": "2008-10-29",
      "res_event_number": "34252",
      "product_code": "CAN",
      "product_description": "Praxair Grab ''n Go Vantage unit, model PRX-9495.",
      "code_info": "All codes (product manufactured from March, 2005 to the present)",
      "firm_fei_number": "3005503166",
      "recalling_firm": "Praxair Distribution Inc.",
      "address_1": "7261 Engle Road, Suite 306 7261 Engle Road",
      "address_2": "Suite 306",
      "city": "Middleburg Heights",
      "state": "OH",
      "postal_code": "44130",
      "additional_info_contact": "Jack Hercik\n440-234-1075",
      "reason_for_recall": "The units may experience a delay in oxygen flow upon initial actuation.",
      "root_cause_description": "Other",
      "action": "The recalling firm sent a recall letter, dated 12/21/05, to all consignees.",
      "product_quantity": "2,486 units of models PRX-9495 and PRX-9496 combined",
      "distribution_pattern": "The product was distributed to 27 institutions and 2 distributors located in OH, MA, IL, CA, UT, PA, MD, and IN and to 2 institutions in Canada:  Moncton, NB  and Ottawa, ON.",
      "openfda": {
        "k_number": [
          "K872170",
          "K811430",
          "K852374",
          "K893621",
          "K942751",
          "K852333",
          "K863711",
          "K803207",
          "K802644",
          "K895956",
          "K852663",
          "K901623",
          "K080243",
          "K914271",
          "K852649",
          "K862193",
          "K915154",
          "K894850",
          "K861166",
          "K853039",
          "K771241",
          "K896152",
          "K162811",
          "K061785",
          "K844622",
          "K843585",
          "K921125",
          "K834061",
          "K932006",
          "K883483",
          "K060265",
          "K884927",
          "K780364",
          "K900115",
          "K780084",
          "K780359",
          "K896128",
          "K813467",
          "K810679",
          "K813466",
          "K891771",
          "K772216",
          "K841367",
          "K850106",
          "K915505",
          "K936187",
          "K830844",
          "K862796",
          "K912174",
          "K950777",
          "K780750",
          "K894302",
          "K901831",
          "K865077",
          "K810132"
        ],
        "registration_number": [
          "",
          "2432235",
          "3008264111",
          "3009327812",
          "9681409",
          "3020460367",
          "2020813",
          "3006446479",
          "8020785",
          "1416980",
          "1417592",
          "3003418325",
          "3029706818",
          "1526809",
          "3013345545",
          "2523148",
          "2025816",
          "3012971441",
          "3004111085",
          "3021841055",
          "3005347827",
          "3004145585",
          "3008115001",
          "3004112621",
          "3030128613",
          "9616354",
          "2085336",
          "3006534178",
          "2183425",
          "3012316249",
          "2085602",
          "3009291251",
          "3022528821",
          "9613416",
          "3005448067",
          "3010387558",
          "1937613",
          "3006563173",
          "3012777736",
          "1610287",
          "3023809973",
          "3003207908",
          "3007019343",
          "3013156250",
          "3002637618",
          "3004034546",
          "1017294",
          "3005380088",
          "9710567",
          "3012311599",
          "3013744387",
          "3008808097",
          "9610105",
          "1044295",
          "9611500",
          "3008812560",
          "3020188747",
          "3003674698",
          "3043127556",
          "1000448358",
          "3013524663",
          "3016426850",
          "1000153536",
          "3008281139",
          "2030745",
          "3020410611",
          "9610861",
          "3010373263",
          "3017406698",
          "3023339109",
          "3008791328",
          "3033959233",
          "3017181414",
          "1836161",
          "2020601",
          "9614084",
          "3004859326",
          "3011237770",
          "1062191",
          "3043047771",
          "3006783791",
          "1000604079",
          "3007222468",
          "2183615",
          "3020751316",
          "1530881",
          "3006395447",
          "9681383",
          "2937398",
          "2225311",
          "3008774304",
          "3008307149",
          "3014810929",
          "3007360714",
          "3010394125",
          "1526863",
          "9615102",
          "3034694958",
          "3005206084",
          "3006157842",
          "3009512503",
          "1121335",
          "1000359047",
          "3014273557",
          "2518435",
          "3021244152",
          "3037012186",
          "3013557686",
          "1419185",
          "1924066",
          "9611451",
          "8010130",
          "3010834934",
          "1832475"
        ],
        "fei_number": [
          "",
          "2432235",
          "3008264111",
          "3009327812",
          "3020460367",
          "2020813",
          "3006446479",
          "1416980",
          "3001104093",
          "1417592",
          "3003418325",
          "3029706818",
          "1526809",
          "3013345545",
          "2523148",
          "2025816",
          "3012971441",
          "3004111085",
          "3021841055",
          "3005347827",
          "3004145585",
          "3002297841",
          "3008115001",
          "3004112621",
          "3002806783",
          "1000271197",
          "3030128613",
          "3001620388",
          "3006534178",
          "2183425",
          "3012316249",
          "3009291251",
          "3022528821",
          "1000509422",
          "3005448067",
          "3010387558",
          "1937613",
          "3006563173",
          "3002750084",
          "3012777736",
          "1610287",
          "3023809973",
          "1000614294",
          "3003207908",
          "3007019343",
          "3013156250",
          "3000719543",
          "3002637618",
          "3004034546",
          "1017294",
          "3005380088",
          "3003418980",
          "3012311599",
          "3013744387",
          "1000306460",
          "3008808097",
          "1044295",
          "3008812560",
          "3020188747",
          "3003674698",
          "3043127556",
          "1000448358",
          "3013524663",
          "3016426850",
          "1000153536",
          "3008281139",
          "3020410611",
          "3010373263",
          "3017406698",
          "3023339109",
          "3008791328",
          "3033959233",
          "3005468265",
          "3017181414",
          "2020601",
          "3004859326",
          "3011237770",
          "3043047771",
          "3006783791",
          "1000604079",
          "3007222468",
          "2183615",
          "3002806988",
          "3020751316",
          "3006395447",
          "2937398",
          "3003256355",
          "3002807836",
          "2225311",
          "3008774304",
          "3008307149",
          "3014810929",
          "3007360714",
          "3010394125",
          "1526863",
          "3034694958",
          "3005206084",
          "3006157842",
          "3009512503",
          "1121335",
          "1000359047",
          "3014273557",
          "2518435",
          "3000210616",
          "3021244152",
          "3037012186",
          "3001655525",
          "3013557686",
          "1419185",
          "3000204983",
          "1924066",
          "3010834934",
          "1832475"
        ],
        "device_name": "Regulator, Pressure, Gas Cylinder",
        "medical_specialty_description": "Anesthesiology",
        "regulation_number": "868.2700",
        "device_class": "1"
      }
    }
  ]
}