      "cfres_id": "42394",
      "product_res_number": "Z-0187-05",
      "event_date_initiated": "2005-10-07",
      "event_date_posted": "2005-10-15",
      "recall_status": "Terminated",
      "event_date_terminated": "2011-02-10",
      "res_event_number": "33759",
      "product_code": "ZZZ",
      "product_description": "CTX 5500 DS and CTX 2500 Explosive Detection Systems (EDS);\n\nProduct is manufactured by InVision Technologies, Inc., Newark, CA",
      "code_info": "All units of these models: CTX: 5500, 2500",
      "firm_fei_number": "3000719027",
      "recalling_firm": "Invision Technologies Inc",
      "address_1": "7151 Gateway Blvd",
      "city": "Newark",
      "state": "CA",
      "postal_code": "94560-1012",
      "reason_for_recall": "X-ray leakage exceed exposure standard of 0.5 mR/hr.",
      "root_cause_description": "Other",
      "action": "On 10/7/05, the firm issued letters to all its direct consignees, informing them of the affected product and providing instructions on the Corrective Action Plan (CAP). The changes will be completed on each CTX 5500/2500 at the next scheduled monthly maintenance visit by InVision Field Service Engineer.",
      "product_quantity": "634 inits",
      "distribution_pattern": "Distributed nationwide primarily in the airports.",