{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-08-13",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "41032",
      "product_res_number": "Z-0299-06",
      "event_date_initiated": "2005-08-05",
      "event_date_posted": "2005-12-23",
      "recall_status": "Terminated",
      "event_date_terminated": "2006-11-09",
      "res_event_number": "32889",
      "product_code": "DTK",
      "k_numbers": [
        "K964284"
      ],
      "product_description": "Stainless Steel Greenfield Vena Cava Filter with 12 Fr. / 4,0 mm FlexCarrier Capsule.  Catalog no. M001505010.  Sterile EO.  Single Use Only.  Manufacturer:  Boston Scientific Cork Ltd., Business and Technology Park, Model Farm Rd., Cork, Ireland.  Distributed in USA by: Boston Scientific Corporation, One Boston Scientific Place, Natick, MA USA  01760.  The devices are permanently implanted devices designed to protect against pulmonary embolism while maintaining patency of the inferior vena cava.  It is inserted through the internal jugular or femoral vein using a percutaneous puncture or surgical cutdown.  The Stainless Steel Greeenfield Vena Cava Filter comes preloaded in a 12 Fr. / 4.0 mm jugular or femoral introducer catheter.",
      "code_info": "Lot numbers:  7132606, 7132607, 7132608, 7133116, 7136847, 7136848, 7142615, 7142616 and 7147508",
      "firm_fei_number": "3002095335",
      "recalling_firm": "Boston Scientific Scimed",
      "address_1": "1 Scimed Pl",
      "city": "Maple Grove",
      "state": "MN",
      "postal_code": "55311-1565",
      "reason_for_recall": "Certain units within eleven lots of the 12 Fr Greenfield Vena Cava Filter may lack a taper on the braided sheath of the delivery system.  The lack of a taper could lead to vessel damage as a result of the sheath catching on the edge of the vein and causing a tear.",
      "root_cause_description": "Other",
      "action": "Urgent Recall Notice dated 08/04/05 was Federal Express''d to customers for delivery on 08/05/05.  This notice informs customers of the issue and identifies affected product.  Customers are asked to immediately discontinue use of and segregate these recalled lots.  Steps for Voluntary Recall and Tracking/Verification Form were sent to the Risk Manager only.    The Tracking/Verification Form is to be completed by the Risk Manager even if there are no affected lots to return.  To return affected product, the customer must call Boston Scientific Corporation (BSC) to obtain a Returned Goods Authorization (RGA) number.  Returned Goods are to be packaged and sent to BSC with the Tracking/Verification Form and using the enclosed red/white field action return shipping label to:  Boston Scientific Marina Bay, 500 Commander Shea Blvd., Quincy, MA  02171",
      "distribution_pattern": "OUS includes countries of Chile, Japan, Netherlands and Taiwan.  Within the US to:  AK, AL, AR, AZ, CA, CO, CT, FL, GA, IA, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, NC, NE, NH, NJ, NY, OH, OR, PA, SC, TN, TX, VA and WI",
      "openfda": {
        "k_number": [
          "K073528",
          "K061815",
          "K022236",
          "K140286",
          "K940489",
          "K121057",
          "K082305",
          "K010083",
          "K101431",
          "K152765",
          "K130366",
          "K003964",
          "K150262",
          "K894703",
          "K901659",
          "K172584",
          "K951508",
          "K032426",
          "K955396",
          "K901235",
          "K081138",
          "K963014",
          "K102511",
          "K062887",
          "K171712",
          "K000855",
          "K034050",
          "K771046",
          "K112497",
          "K133243",
          "K031328",
          "K070514",
          "K912035",
          "K081410",
          "K241507",
          "K120402",
          "K072240",
          "K090140",
          "K023116",
          "K163699",
          "K964284",
          "K874096",
          "K233680",
          "K093659",
          "K113124",
          "K063217",
          "K160866",
          "K173236",
          "K091077",
          "K112119",
          "K172557",
          "K881604",
          "K240257",
          "K052578",
          "K901454",
          "K240578",
          "K010485",
          "K760152",
          "K143208",
          "K760151",
          "K162875",
          "K870729",
          "K161218",
          "K912144",
          "K043509",
          "K970099",
          "K122585",
          "K963016",
          "K000062",
          "K242612",
          "K080668",
          "K050558",
          "K121629",
          "K073374",
          "K932921",
          "K143405",
          "K925679",
          "K211874",
          "K852097",
          "K181202",
          "K211875",
          "K073090",
          "K944353"
        ],
        "pma_number": [
          "P850049"
        ],
        "registration_number": [
          "3013764800",
          "3002807314",
          "3009888344",
          "3010383847",
          "2020394",
          "3009526575",
          "3002808486",
          "1625425",
          "1313046",
          "1643817",
          "3005580113",
          "1018233",
          "1721686",
          "3007080617",
          "3007156625",
          "1016427",
          "1722746",
          "3006082230",
          "9616099",
          "1820334",
          "3004111573",
          "9612452"
        ],
        "fei_number": [
          "3013764800",
          "3003528016",
          "3002807314",
          "3009888344",
          "3010383847",
          "2020394",
          "1000306216",
          "3009526575",
          "3002806713",
          "3002808486",
          "1625425",
          "1313046",
          "1643817",
          "3005580113",
          "1018233",
          "1721686",
          "3007080617",
          "1016427",
          "3006082230",
          "1820334",
          "3008133910",
          "3004111573"
        ],
        "device_name": "Filter, Intravascular, Cardiovascular",
        "medical_specialty_description": "Cardiovascular",
        "regulation_number": "870.3375",
        "device_class": "2"
      }
    }
  ]
}