  "results": [
    {
      "cfres_id": "36821",
      "product_res_number": "Z-0702-05",
      "event_date_initiated": "2004-04-12",
      "event_date_posted": "2005-04-13",
      "recall_status": "Terminated",
      "event_date_terminated": "2006-07-22",
      "res_event_number": "30929",
      "product_code": "MLM",
      "pma_numbers": [
        "P970025"
      ],
      "product_description": "Version 12 software program written for the Bio-Tek ELx800 automated microtiter plate reader with use of PRO-Trac Tacrolimus ELISA kit",
      "code_info": "version 12",
      "firm_fei_number": "2182595",
      "recalling_firm": "Diasorin Inc.",
      "address_1": "1951 Northwestern Ave S",
      "city": "Stillwater",
      "state": "MN",
      "postal_code": "55082-7536",
      "additional_info_contact": "DiaSorin Technical Services\n800-328-1482",
      "reason_for_recall": "The software program written for use in the automated microtiter plate reader (Bio-Tek ELx800) for use with the Pro-Trac II Tacrolimus ELISA kit was found to be faulty.  Assay software program did not include the Calibrator Zero OD specification (STDO>=1.500) as specified in the product insert.",
      "root_cause_description": "Other",
      "action": "Customers were sent notification letters and effectiveness check form. recommended users manually veify results using product insert specifications.",
      "distribution_pattern": "CA, Washington DC, FL, KY  & Canada",
      "openfda": {
        "k_number": [
          "K060502",
          "K150168",
          "K173857",
          "K060385",
          "K203833",
          "K123343",
          "K050206",
          "K063868",
          "K070820"
        ],
        "pma_number": [
          "P970007",
          "P970025"
        ],
        "registration_number": [
          "1643621",
          "2432235",
          "3005333358",
          "3008344661",
          "1218959",
          "1415939",
          "9616673",
          "2517506",
          "9610126",
          "3026848661",
          "2521625",
          "3010939897",
          "3003951180"
        ],
        "fei_number": [
          "1643621",
          "2432235",
          "3005333358",
          "3008344661",
          "1415939",
          "1218959",
          "3002806559",
          "2517506",
          "3003179344",
          "3026848661",
          "2521625",
          "3010939897",
          "3003951180"
        ],
        "device_name": "Enzyme Immunoassay, Tracrolimus",
        "medical_specialty_description": "Clinical Chemistry",
        "regulation_number": "862.1678",
        "device_class": "2"
      }
    }
  ]
}