{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-08-20",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "35097",
      "product_res_number": "Z-0010-05",
      "event_date_initiated": "2004-09-14",
      "event_date_created": "2015-06-25",
      "recall_status": "Terminated",
      "event_date_terminated": "2005-03-03",
      "res_event_number": "30059",
      "product_code": "LZG",
      "k_numbers": [
        "K030531"
      ],
      "product_description": "Medtronic MiniMed Paradigm Model 712",
      "code_info": "Paradigm model 712pumps with serial numbers that end in '-Dxx3' .  Where 'x' can be any number or letter.",
      "firm_fei_number": "3003166194",
      "recalling_firm": "Medtronic MiniMed",
      "address_1": "18000 Devonshire St",
      "city": "Northridge",
      "state": "CA",
      "postal_code": "91325-1219",
      "additional_info_contact": "800-646-4633",
      "reason_for_recall": "Several complaints of pumps exhibiting A47 alarms were received.  Investigation revealed the alarms occurred when the pump attempted to display text that exceeded the maximum display length of the pump screen. The investigation revealed this only occurs when the pump is programmed to display information in Spanish.",
      "root_cause_description": "Other",
      "product_quantity": "10,600",
      "distribution_pattern": "Nationwide & Spain",
      "openfda": {
        "k_number": [
          "K022317",
          "K042792",
          "K013807",
          "K043000",
          "K160482",
          "K160056",
          "K900498",
          "K021439",
          "K223372",
          "K994186",
          "K093364",
          "K991376",
          "K142619",
          "K041317",
          "K100567",
          "K031738",
          "K042873",
          "K141758",
          "K082595",
          "K905693",
          "K062323",
          "K030531",
          "K133593",
          "K041318",
          "K071788",
          "K022394",
          "K071613",
          "K960001",
          "K103825",
          "K032164",
          "K063126",
          "K162296",
          "K031373",
          "K100504",
          "K180045",
          "K160252",
          "K050312",
          "K082590",
          "K022831",
          "K192659",
          "K023471",
          "K111353",
          "K143189",
          "K211575",
          "K131294",
          "K993012",
          "K032257",
          "K050760",
          "K182630",
          "K053177",
          "K080639",
          "K073356",
          "K210714",
          "K253534",
          "K901588",
          "K111210",
          "K083225",
          "K884978",
          "K040676",
          "K963948",
          "K162080",
          "K042887",
          "K031541",
          "K001604",
          "K090245",
          "K070844",
          "K140439",
          "K120206",
          "K973044",
          "K240158",
          "K993184",
          "K122483",
          "K051041",
          "K020655",
          "K050971",
          "K013309",
          "K990801",
          "K060876",
          "K111669",
          "K021725",
          "K972107",
          "K122953",
          "K063674",
          "K241622"
        ],
        "registration_number": [
          "3009515470",
          "3005340341",
          "3027453514",
          "3042027705",
          "9616814",
          "1313700",
          "3012421607",
          "3008824097",
          "2029275",
          "3006479639",
          "3020976354",
          "3010162782",
          "3007007790",
          "3007981285",
          "3005627859",
          "9610126",
          "3013636348",
          "2246552",
          "3010047442",
          "3007710663",
          "3014585508",
          "1721676",
          "3009337401",
          "3006194679",
          "3001058982",
          "9617604",
          "3016540876",
          "3015218509",
          "1220477",
          "3008810357",
          "3010291427",
          "3011393376",
          "3002806818",
          "2032227",
          "3007939342",
          "3007871880",
          "3013756811"
        ],
        "fei_number": [
          "3009515470",
          "3002806559",
          "3005340341",
          "3027453514",
          "3042027705",
          "1313700",
          "3003166194",
          "3002558692",
          "3012421607",
          "3008824097",
          "3006479639",
          "3004173703",
          "3020976354",
          "1000306431",
          "3010162782",
          "3007007790",
          "3007981285",
          "3005627859",
          "3013636348",
          "2246552",
          "3010047442",
          "3014585508",
          "1721676",
          "3009337401",
          "3006194679",
          "3003024060",
          "3001058982",
          "3016540876",
          "3015218509",
          "1220477",
          "3008810357",
          "3010291427",
          "3011393376",
          "3002806818",
          "3007939342",
          "3007871880",
          "3013756811"
        ],
        "device_name": "Pump, Infusion, Insulin",
        "medical_specialty_description": "General Hospital",
        "regulation_number": "880.5725",
        "device_class": "2"
      }
    }
  ]
}