  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-08-13",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "30769",
      "product_res_number": "Z-0313-04",
      "event_date_initiated": "2003-08-23",
      "event_date_posted": "2004-01-09",
      "recall_status": "Terminated",
      "event_date_terminated": "2005-01-04",
      "res_event_number": "27936",
      "product_code": "MEB",
      "product_description": "Easypump LT 100-200\n\nElastomeric Infusion Pump (100 ml x 0.5 ml/hr)\n\nPart number: 5001120",
      "code_info": "Lot number 132185.",
      "firm_fei_number": "3011270181",
      "recalling_firm": "I-Flow Corporation",
      "address_1": "20202 Windrow Dr",
      "city": "Lake Forest",
      "state": "CA",
      "postal_code": "92630-8152",
      "additional_info_contact": "Shane Noehre\n949-206-2653",
      "reason_for_recall": "Some pumps run at 2 ml/hr instead of 0.5 ml/hr.",
      "root_cause_description": "Other",
      "action": "Firm sent recall letter to thier only customer in France on August 23, 2002.",
      "product_quantity": "950",
      "distribution_pattern": "Only to France, and one customer.",
      "openfda": {
        "k_number": [
          "K992015",
          "K993832",
          "K060933",
          "K911636",
          "K003915",
          "K993972",
          "K930404",
          "K954059",
          "K071222",
          "K061409",
          "K020862",
          "K011317",
          "K982102",
          "K040752",
          "K971362",
          "K965222",
          "K181360",
          "K081905",
          "K041585",
          "K040337",
          "K250234",
          "K062457",
          "K052117",
          "K963355",
          "K010824",
          "K972158",
          "K990889",
          "K991543",
          "K131249",
          "K940117",
          "K944665",
          "K000263",
          "K971168",
          "K052999",
          "K242152",
          "K922382",
          "K021964",
          "K071735",
          "K090300",
          "K072053",
          "K983454",
          "K020660",
          "K050770",
          "K011117",
          "K962663",
          "K992551",
          "K051474",
          "K955727",
          "K002321",
          "K071532",
          "K020988",
          "K063530",
          "K023883",
          "K151650",
          "K060258",
          "K002073",
          "K982946",
          "K960318",
          "K001342",
          "K914148",
          "K052451",
          "K061661",
          "K980558",
          "K983634",
          "K240624",
          "K990461",
          "K003476",
          "K943664",
          "K982256",
          "K941418",
          "K023098",
          "K042246",
          "K941766",
          "K033039",
          "K940406",
          "K030830",
          "K913658",
          "K023318",
          "K972173",
          "K131247",
          "K013928",
          "K953028",
          "K072921",
          "K955849",
          "K021274",
          "K042122",
          "K051828",
          "K984502"
        ],
        "registration_number": [
          "3003898360",
          "3013764800",
          "",
          "2029275",
          "9680425",
          "3024702421",
          "2025695",
          "3011270181",
          "3011137372",
          "3012429465",
          "1416980",
          "3010041511",
          "3022518300",
          "9612086",
          "2030624",
          "3005126704",
          "3010220595",
          "9610825",
          "1319639",
          "3004365956",
          "3002907620",
          "3009171251",
          "3010055973",
          "9680787"
        ],
        "fei_number": [
          "3003898360",
          "3013764800",
          "",
          "3024702421",
          "1000138054",
          "3002826093",
          "2025695",
          "3011270181",
          "3012429465",
          "1416980",
          "3010041511",
          "3022518300",
          "1000306431",
          "3005126704",
          "3006759904",
          "3002806469",
          "3010220595",
          "3007596547",
          "3002806575",
          "3005747797",
          "3004365956",
          "3002907620",
          "3010055973",
          "3000206435"
        ],
        "device_name": "Pump, Infusion, Elastomeric",
        "medical_specialty_description": "General Hospital",
        "regulation_number": "880.5725",
        "device_class": "2"
      }
    }
  ]
}