{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-08-15",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "30444",
      "product_res_number": "Z-0247-04",
      "event_date_initiated": "2003-10-10",
      "event_date_posted": "2003-12-18",
      "recall_status": "Terminated",
      "event_date_terminated": "2016-01-28",
      "res_event_number": "27738",
      "product_code": "FEM",
      "product_description": "Smith & Nephew  Endocoupler C-Mount 30mm Focal Length\nReference: 7204823 and 7204823S (S indicates unit previously serviced)",
      "code_info": "Part Number: 7204823, Camera Coupler, C-Mount, 30mm F.L. \tSerial Numbers (SR prefix):  8632\t8646\t8652\t8659\t8670\t8679\t8693\t8709\t8714 8633\t8647\t8655\t8660\t8675\t8686\t8694\t8711\t8716 8635\t8648\t8657\t8665\t8676\t8687\t\t8712\t8727 8636\t8649\t8658\t8668\t8677\t8691\t8707\t8713\t8728  Part Number: 7204823S, Camera Coupler, C-Mount, 30mm F.L. Serial Number SR8705",
      "firm_fei_number": "3003604053",
      "recalling_firm": "Smith And Nephew, Inc. Endoscopy Division",
      "address_1": "150 Minuteman Rd",
      "city": "Andover",
      "state": "MA",
      "postal_code": "01810-1031",
      "additional_info_contact": "Jason Bilobram\n978-474-6332",
      "reason_for_recall": "Hardware of the camera coupler may rust and result in an ineffective sterilization/cleaning process.",
      "root_cause_description": "Nonconforming Material/Component",
      "action": "Smith & Nephew notified direct accounts by letter on 10/15/03.  Service representatives will remove and replace product.",
      "product_quantity": "35 units",
      "distribution_pattern": "Nationwide to hospitals\nForeign: Australia, Africa, Belgium, Canada, China, Dubai, Egypt, Germany, D\\Godmanchester, Italy, Japan, Korea, Malaysia, Norway, Portugal, Singapore, South Africa, Thailand, Taiwan.",
      "openfda": {
        "device_name": "Accessories, Photographic, For Endoscope (Exclude Light Sources)",
        "medical_specialty_description": "Gastroenterology, Urology",
        "regulation_number": "876.1500",
        "device_class": "1",
        "k_number": [
          "K812201",
          "K812542",
          "K792512",
          "K940152"
        ],
        "registration_number": [
          "3002808148",
          "1222616",
          "9610612",
          "3011373951",
          "3027655341",
          "3008494403",
          "3012447612",
          "1836161",
          "3021226419",
          "3042225166",
          "3010202439",
          "9614209",
          "9611174",
          "3012797688",
          "8010047",
          "3005099803",
          "1225968",
          "2936485",
          "3021336182",
          "3001556604",
          "2027009",
          "9610691",
          "1833053",
          "9610877",
          "8043980",
          "3015168749",
          "3003775006",
          "3016436764",
          "2938071",
          "3006161756",
          "3008114965",
          "3011459664",
          "3033043422",
          "3030926959",
          "3003782610",
          "1222773",
          "3004443374",
          "8030607",
          "1418479",
          "2183911",
          "3021393544",
          "3001644167",
          "3013831261",
          "3019512034",
          "1220246",
          "9611112",
          "2124215",
          "1221934",
          "9611102",
          "9610617",
          "3012843412",
          "3012883081",
          "3034676720",
          "3014498758",
          "2085947",
          "3014342096",
          "3016050940",
          "3010331645",
          "1017294",
          "3019530907",
          "3016045249",
          "3010399422",
          "3008953712"
        ],
        "fei_number": [
          "3002750084",
          "3002808148",
          "3000204191",
          "3010399422",
          "3011373951",
          "3006509795",
          "3002807795",
          "3008185830",
          "3008494403",
          "3012447612",
          "3027655341",
          "3021226419",
          "3042225166",
          "3007475226",
          "3012797688",
          "3002480801",
          "3005099803",
          "2936485",
          "3021336182",
          "3001556604",
          "3002806725",
          "2027009",
          "3002808001",
          "1833053",
          "3016436764",
          "3015168749",
          "3003775006",
          "1000120768",
          "3002914049",
          "2938071",
          "3002806359",
          "3008114965",
          "3011459664",
          "3033043422",
          "3030926959",
          "3002806315",
          "3003782610",
          "3004443374",
          "1418479",
          "3001644167",
          "3021393544",
          "3008782585",
          "3013831261",
          "3019512034",
          "1220246",
          "2124215",
          "3002808127",
          "1221934",
          "3012843412",
          "3012883081",
          "3034676720",
          "3014498758",
          "1000162602",
          "3014342096",
          "3002808268",
          "3016050940",
          "3010331645",
          "1017294",
          "1000120916",
          "3019530907",
          "3016045249",
          "1000116142",
          "3008953712"
        ]
      }
    }
  ]
}