{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-08-15",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "210637",
      "product_res_number": "Z-0364-2025",
      "event_date_initiated": "2024-09-11",
      "event_date_posted": "2024-11-12",
      "recall_status": "Open, Classified",
      "res_event_number": "95570",
      "product_code": "KNY",
      "k_numbers": [
        "K051593"
      ],
      "product_description": "Brand Name: UroPass Ureteral Access Sheaths\nProduct Name: Ureteral Access Sheaths\nModel/Catalog Number: 61024BX, 61038BX, 61046BX, 61054BX, 61124BX, 61138BX, 61146BX, 61154BX, 61224BX, 61238BX, 61246BX, 61254BX, 61324BX, 61338BX, 61346BX, 61354BX\nSoftware Version: N/A\nProduct Description: The Olympus UroPass Ureteral Access Sheath Set consists of a hydrophilic coated outer sheath and an inner tapered dilator intended to establish a conduit for the passage of endoscopes and retrieval devices into the ureter. The hydrophilic coating on the UroPass Ureteral Access Sheath eases passage and placement. Both the outer sheath and inner dilator are radio-opaque for ease of viewing radiographically. Intended for single use only.\nComponent: N/A",
      "code_info": "Model/UDI-DI: 61024BX/00821925035317, 61038BX/00821925035324, 61046BX/00821925035331, 61054BX/00821925035348, 61124BX/00821925035355, 61138BX/00821925035362, 61146BX/00821925035379, 61154BX/00821925035386, 61224BX/00821925035393, 61238BX/00821925035409, 61246BX/00821925035416, 61254BX/00821925035423, 61324BX/00821925035430, 61338BX/00821925035447, 61346BX/00821925035454, 61354BX/00821925035461.",
      "firm_fei_number": "2429304",
      "recalling_firm": "Olympus Corporation of the Americas",
      "address_1": "3500 Corporate Pkwy",
      "city": "Center Valley",
      "state": "PA",
      "postal_code": "18034-8229",
      "additional_info_contact": "Cynthia Ow\n647-9993203",
      "reason_for_recall": "Exposure of the UroPass product to Ultraviolet ( UV ) Radiation can cause brittleness of the device dilator tip, which may lead to broken dilator tips in the package or in patients during surgical procedures.",
      "root_cause_description": "Storage",
      "action": "****UPDATE Nov 8, 2024***\nOlympus mailed a revision letter-URGENT: MEDICAL DEVICE CORRECTION\nUPDATED INFORMATION to consignees on November 8, 2024. Letter states;\nTo reduce the risk of UV exposure to your device(s), Olympus instructs users to implement the following actions:\nMinimize the exposure of UroPass Ureteral Access Sheaths to ultraviolet light. Exposure to UV light during storage periods may cause embrittlement of this device, increasing the potential for breakage and patient injury, including retained device fragments, tissue damage, or perforation of the ureter.\nUpdated Information:\n\" As instructed in IFU Section 4.0, inspect the device prior to use. If any damage to the device is noted, DO NOT USE.\n\" Inspect the device upon removal or completion of the procedure. If damage is noted, the patient should be evaluated for a potentially retained foreign body.\n\" Sharp edges of a broken sheath have been reported to have caused ureteral tissue damage or perforation. If device damage is noted, patients should be monitored intraoperatively and in the immediate post-operative period for these types of injuries.\nOlympus is not requiring the return of your UroPass device(s) as a result of this action. However, if you want to return the UroPass device(s) in your inventory, please contact Customer Service at 1-800-848-9024, option 2 to obtain a Return Material Authorization. Olympus will issue a credit to your facility upon return of your affected product.\n4. Ensure all personnel are completely knowledgeable and thoroughly trained on the content of this notification, including the new information regarding UV exposure. Olympus is in the process of updating the Instructions for Use with this information.\n5. Olympus requests that you acknowledge receipt of this letter. Access the Olympus recall portal to indicate that you have received this notification.\na. Go to https://olympusamerica.com/recall\nb. Enter the recall number \"0458 \nc. Complete the form as instructed.\n6. If",
      "product_quantity": "14,093 units",
      "distribution_pattern": "Worldwide distribution - US Nationwide and the countries of Australia, Canada, China, Germany, Hong Kong, Japan, Republic of South Korea, Singapore.",
      "openfda": {
        "k_number": [
          "K944754",
          "K120160",
          "K040520",
          "K951488",
          "K925281",
          "K140441",
          "K914211",
          "K954132",
          "K890072",
          "K873288",
          "K760943",
          "K944135",
          "K952414",
          "K925161",
          "K931013",
          "K090121",
          "K141252",
          "K926344",
          "K000767",
          "K932143",
          "K972977",
          "K051593",
          "K182144",
          "K942074",
          "K032127",
          "K052952",
          "K981229",
          "K923496",
          "K934072",
          "K042531",
          "K062240",
          "K882641",
          "K042877",
          "K943835",
          "K052134",
          "K991097",
          "K921200",
          "K913679",
          "K023690",
          "K896806",
          "K123170",
          "K781987",
          "K942205",
          "K131803",
          "K821336",
          "K951995",
          "K960866",
          "K905128",
          "K052298",
          "K935643",
          "K926039",
          "K884819",
          "K981667",
          "K112209",
          "K921055",
          "K912919",
          "K981611",
          "K912146",
          "K881878",
          "K771212",
          "K162356",
          "K833242",
          "K900031",
          "K260919",
          "K140562"
        ],
        "device_name": "Accessories, Catheter, G-U",
        "medical_specialty_description": "Gastroenterology, Urology",
        "regulation_number": "876.5130",
        "device_class": "2",
        "registration_number": [
          "9681477",
          "1713468",
          "1625425",
          "2032112",
          "2032098",
          "3005232773",
          "3009763019",
          "3002807314",
          "3010202439",
          "3016171914",
          "3004111573",
          "1423537",
          "2183744",
          "1921846",
          "2027111",
          "3003915875",
          "9680787",
          "9611590",
          "3009051888",
          "9617594",
          "3012322232",
          "3016096097",
          "2022435",
          "2020550",
          "2029015",
          "2126666",
          "8010418",
          "1018233",
          "1220477",
          "3011050570",
          "3006082230",
          "9610617",
          "3010155661",
          "2029275",
          "9612030",
          "3006174295",
          "3010707607",
          "3014342096",
          "3003790304"
        ],
        "fei_number": [
          "1713468",
          "1625425",
          "3003076831",
          "3005232773",
          "3007130719",
          "3009763019",
          "3002807314",
          "3007475226",
          "3016171914",
          "3004111573",
          "2183744",
          "3002806934",
          "1921846",
          "2027111",
          "3003915875",
          "3009051888",
          "3012322232",
          "1000160458",
          "3016096097",
          "2022435",
          "3001236905",
          "2020550",
          "2126666",
          "1018233",
          "3002807439",
          "1220477",
          "3011050570",
          "1000237915",
          "3002826093",
          "3006082230",
          "3010155661",
          "1000306431",
          "3006174295",
          "3010707607",
          "3014342096",
          "3002808268",
          "3003058448",
          "3003790304",
          "3003807466"
        ]
      }
    }
  ]
}