{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-08-20",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "210097",
      "product_res_number": "Z-0043-2025",
      "event_date_initiated": "2024-09-05",
      "event_date_posted": "2024-10-09",
      "recall_status": "Open, Classified",
      "res_event_number": "95377",
      "product_code": "QLT",
      "product_description": "NxTAG Respiratory Pathogen Panel +SARS-CoV-2, REF: I056C0468",
      "code_info": "Lot/Expiration:\nIK056C-0033/ 9/30/2024,\nIK056C-0034/ 10/31/2024,\nIK056C-0035/ 10/31/2024,\nIK056C-0036/ 12/31/2024,\nIK056C-0037/ 12/31/2024,\nIK056C-0038/ 12/31/2024,\nIK056C-0039/ 1/31/2025",
      "firm_fei_number": "3002777243",
      "recalling_firm": "Luminex Molecular Diagnostics Inc",
      "address_1": "439 University Ave Suite 900 439 University Ave",
      "address_2": "Suite 900",
      "city": "Toronto",
      "country": "Canada",
      "reason_for_recall": "Respiratory pathogen panel may report an elevated rate  (7.6% predicted probability of occurrence) of non-specific hMPV target (human Metapneumovirus) results, risk identified predominantly in clinical samples that present positivity for another target, leading to an erroneous co-infection result, can potentially result in hMPV false positives.",
      "root_cause_description": "Device Design",
      "action": "On 9/5/24, recall notices were sent to customers and distributors were were asked to do the following:\n1. Two options are available to overcome the sporadic potential risk of the hMPV false positive result:\nA. Continue to use the product as per its instruction for use: in case of a positive result for\nhMPV, consider performing confirmatory testing with another method before reporting\nthe hMPV result, if medically indicated.\nB. Exclude the hMPV from the reporting by removing this target from the assay analysis, as\nexplained in the package insert under the chapter \"Define Test Panels in SYNCT Software\". See Document No. and Revision/Page reference: MLD-051-KPI-001 Rev H/Page 17, MLD-056-KPI-001 Rev. E/Page 18.\n2. Notify others within your network that may have remaining inventory of those kits.\n3. If you are a distributor, provide a copy of this letter to customers or organizations who received impacted lots.\n4. Complete and return the response form via email to support@luminexcorp.com\n5. For complaints, questions, or concerns, please contact Technical Support using the contact information:\n1-877-785-2323 (U.S. and Canada).\n+1-512-381-4397 (Outside U.S. and Canada).\n1-512-219-5114 (Fax).\nsupport@luminexcorp.com\nwww.diasorin.com",
      "product_quantity": "613",
      "distribution_pattern": "U Nationwide distribution in the states of OH, CA, NC, WI, TN, TX, MI, NY, MO, FL, MA, NJ, PA, VA, AZ, IL, OK, CO, MN.",
      "openfda": {
        "registration_number": [
          "1528450",
          "3004141078",
          "2024800",
          "3038610665",
          "2243471",
          "3017638293",
          "2024674",
          "3013019728",
          "3014214006"
        ],
        "fei_number": [
          "3004141078",
          "2024800",
          "3038610665",
          "1000122536",
          "2243471",
          "3017638293",
          "2024674",
          "3013019728",
          "3014214006"
        ],
        "device_name": "Covid-19 Multi-Analyte Respiratory Panel Nucleic Acid Devices",
        "medical_specialty_description": "Unknown",
        "regulation_number": "",
        "device_class": "N"
      }
    }
  ]
}