{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-08-13",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "196755",
      "product_res_number": "Z-0355-2023",
      "event_date_initiated": "2022-10-25",
      "event_date_posted": "2022-12-02",
      "recall_status": "Open, Classified",
      "res_event_number": "91108",
      "product_code": "CDZ",
      "k_numbers": [
        "K032881"
      ],
      "product_description": "IMMULITE and IMMULITE 1000 Total Testosterone Assay- In vitro diagnostic use with the IMMULITE and IMMULITE 1000 Analyzers for the quantitative measurement of total testosterone in serum and heparinized plasma.",
      "code_info": "UDI: (01)00630414964782(10)0515(17)20221130;  (01)00630414964782(10)0516(17)20221231\nLot Numbers: \n515, Exp Date: 2022-11-30\n516,  Exp Date: 2022-12-31",
      "firm_fei_number": "1219913",
      "recalling_firm": "Siemens Healthcare Diagnostics, Inc.",
      "address_1": "333 Coney St",
      "city": "East Walpole",
      "state": "MA",
      "postal_code": "02032-1516",
      "additional_info_contact": "SAME\n508-668-5000",
      "reason_for_recall": "Confirmed an average positive bias of 40% for testosterone concentrations of approximately 660 ng/dL (22.9 nmol/L) and above with the IMMULITE/IMMULITE 1000 Total Testosterone Assay when compared to the IMMULITE 2000/IMMULITE 2000 XPi Total Testosterone Assay. Two (2) lots of Total Testosterone assays for the IMMULITE/IMMULITE 1000, kit lots #515 and #516 were actively distributed to customers when the issue was discovered by Siemens, and they are subject to the correction or removal in this recall (867 total quantity of reagents distributed for each lot).\n\nThe violative product may cause temporary or medically reversible adverse health consequences or where the probability of serious adverse health consequences is remote. In both males and female, testosterone results are not used in isolation but are interpreted in conjunction with clinical history and symptomology as well as with other laboratory testing (e.g. gonadotropins and other sex steroids). A delay in the diagnosis may be experienced and medical intervention, such as repeat testing may be required.",
      "root_cause_description": "Process control",
      "action": "Siemens has issued an \"Urgent Medical Device Correction (UMDC)\" IMC 23-02.A.US to US customers via FedEx beginning on 10/25/2022. An Urgent Field Safety Notice (UFSN) IMC 23-02.A.OUS to Outside the US (OUS) customers for distribution and regional reporting to their local competent authorities beginning on 10/25/2022. Letters states reason for recall, health risk and action to take:\n\nPlease review this letter with your Medical Director.\nYou may continue use of the IMMULITE/IMMULITE 1000 Total Testosterone Assay kit lots\nlisted in Table 1 to report values below 660 ng/dL (22.9 nmol/L) until you receive\nreplacement product in your laboratory. Refer to Figures 1 and 2 for IMMULITE/IMMULITE\n1000 Total Testosterone bias information.\nIf you are currently using IMMULITE/IMMULITE 1000 Total Testosterone Assay kit lots\nlisted in Table 1, review your inventory needs of these products, and order replacement\nproducts by completing the Field Correction Effectiveness Check Form attached to this\nletter.\nUpon acceptance of the re-aligned replacement lots, discontinue use of and discard the\nproducts listed in Table 1. Refer to Figures 3 - 6 for expected results with replacement lots.\nComplete and return the Field Correction Effectiveness Check Form attached to this letter within 30 days.\nIf you have received any complaints of illness or adverse events associated with the\nproducts listed in Table 1, immediately contact your local Siemens Healthineers Customer Care Center or your local Siemens Healthineers technical support representative.\n\nPlease retain this letter with your laboratory records and forward this letter to those who may have received this product. If you have any questions, please contact your Siemens Healthineers Customer Care Center or your local Siemens Healthineers technical support representative.",
      "product_quantity": "867 units",
      "distribution_pattern": "Worldwide Distribution: US (nationwide) to states of: AL, CA, FL, GA, IN, KY, NC, NE, OR,                  \nSD, TX, UT; and OUS (Foreign) to countries of: Canada, Mexico, Austria, Argentina, Austria, Bangladesh, Colombia, Brazil, Bulgaria, Costa¿Rica, Cyprus, Estonia, Germany, Greece, India, U.A.E., Italy, Kazakhstan, Latvia, P.R.¿China, Romania, Russian¿Fed., South Africa, Spain, United Kingdom, Uruguay and Singapore.¿¿¿¿",
      "openfda": {
        "k_number": [
          "K905247",
          "K955870",
          "K151986",
          "K151529",
          "K971823",
          "K014120",
          "K800776",
          "K883267",
          "K802135",
          "K052649",
          "K201908",
          "K802661",
          "K932951",
          "K912850",
          "K191533",
          "K240865",
          "K021326",
          "K915570",
          "K800921",
          "K862483",
          "K091867",
          "K001935",
          "K955440",
          "K853865",
          "K233480",
          "K190121",
          "K841948",
          "K860130",
          "K023091",
          "K002294",
          "K191350",
          "K813059",
          "K803001",
          "K830512",
          "K973900",
          "K000043",
          "K924257",
          "K964889",
          "K143075",
          "K120009",
          "K941797",
          "K772191",
          "K801666",
          "K093421",
          "K861679",
          "K791999",
          "K021972",
          "K001086",
          "K934562",
          "K152155",
          "K790007",
          "K031717",
          "K963080",
          "K122793",
          "K952281",
          "K030730",
          "K884809",
          "K915823",
          "K032881",
          "K152185",
          "K940449",
          "K181017",
          "K854674",
          "K060818",
          "K083867",
          "K860003",
          "K813401",
          "K831342",
          "K811536",
          "K101388",
          "K983212",
          "K840187",
          "K252728",
          "K223405",
          "K102814",
          "K153577",
          "K841042",
          "K951685",
          "K854671",
          "K182521",
          "K844423",
          "K802728",
          "K211685",
          "K133491",
          "K780792",
          "K041866",
          "K915164",
          "K955102",
          "K904100"
        ],
        "registration_number": [
          "2032682",
          "2245285",
          "3012963943",
          "3007118747",
          "9710337",
          "9612316",
          "3011989923",
          "3007349751",
          "3010324880",
          "1319681",
          "3004192065",
          "8023018",
          "1415939",
          "8032314",
          "3002809144",
          "2182595",
          "3003559191",
          "2029372",
          "3009092698",
          "2419955",
          "9610126",
          "2250051",
          "8031673",
          "2020726",
          "3007361513",
          "2133982",
          "9615037",
          "1063851",
          "1827821",
          "9610746",
          "2517506",
          "1222302",
          "2032087",
          "1219913",
          "1036362",
          "2032839",
          "8020888",
          "3007111389",
          "3005984081",
          "3002642396",
          "2018685",
          "3003030793",
          "3005542422",
          "3005333358",
          "8021924",
          "3002806944",
          "3033967997",
          "8010132",
          "2432235",
          "3003385757",
          "3006198300",
          "3000308930",
          "2122870",
          "3022178699",
          "3002800697",
          "3005529799",
          "1832216"
        ],
        "fei_number": [
          "3004185580",
          "2245285",
          "3002808328",
          "3012963943",
          "3007118747",
          "3003952975",
          "3002807272",
          "3011989923",
          "3007349751",
          "3010324880",
          "3004192065",
          "1415939",
          "3002676602",
          "3002809144",
          "2182595",
          "3003559191",
          "3009092698",
          "2419955",
          "2250051",
          "2967",
          "2020726",
          "3007361513",
          "1827821",
          "3002806559",
          "2517506",
          "3003261083",
          "1219913",
          "1000121039",
          "3002806557",
          "1000306617",
          "1036362",
          "1000136573",
          "3002808140",
          "3002806808",
          "3007111389",
          "3005984081",
          "3002642396",
          "2018685",
          "3003030793",
          "3005542422",
          "3000717645",
          "3005333358",
          "3002485711",
          "3002806944",
          "3033967997",
          "3007019572",
          "2432235",
          "1000442352",
          "3003385757",
          "3006198300",
          "3000308930",
          "2122870",
          "3022178699",
          "3002800697",
          "3005529799",
          "1832216",
          "3003355251"
        ],
        "device_name": "Radioimmunoassay, Testosterones And Dihydrotestosterone",
        "medical_specialty_description": "Clinical Chemistry",
        "regulation_number": "862.1680",
        "device_class": "1"
      }
    }
  ]
}