{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-08-15",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "183979",
      "product_res_number": "Z-0388-2021",
      "event_date_initiated": "2020-09-24",
      "event_date_created": "2020-11-02",
      "recall_status": "Terminated",
      "event_date_terminated": "2022-05-20",
      "res_event_number": "86521",
      "product_code": "JDI",
      "product_description": "ZCA All Poly Acetabular Cup Longevity Crosslinked Polyethylene, I.D. 26 mm, 10 degree inclined face, O.D. Cup with Spacers, 61 mm\n\nNumber: 00-8065-658-26",
      "code_info": "All lots",
      "firm_fei_number": "1000220733",
      "recalling_firm": "Zimmer Biomet, Inc.",
      "address_1": "1800 W Center St",
      "city": "Warsaw",
      "state": "IN",
      "postal_code": "46580-2304",
      "additional_info_contact": "411 Technical Services\n574-371-3071",
      "reason_for_recall": "Sterilant (hydrogen peroxide) used in acetabular cup hip prosthesis component was not evaluated to confirm the biocompatibility of the residual sterilant.  Cannot rule out the potential for adverse tissue reactions.",
      "root_cause_description": "Device Design",
      "action": "Zimmer Biomet issued URGENT MEDICAL DEVICE RECALL AND NOTICE OF US FIELD DISCONTINUATION letter to Distributors. Risk Manages, Physicianson/ 9/24/20 stating reason for recall, heath risk and action to take:\n1.Review this notification and ensure that affected personnel are aware of the contents.\n2. If you have affected product at your facility, assist your Zimmer Biomet sales representative and quarantine all affected product. Your Zimmer Biomet sales representative will remove the affected product from your facility.\n3. Complete Attachment 1  Certificate of Acknowledgement and send to CorporateQuality.PostMarket@zimmerbiomet.com. This form will be returned even if you do not have affected products at your facility.\n4. Retain a copy of the acknowledgement form with your recall records in the event of a compliance audit of your facilitys documentation.\n5. If you have further questions or concerns after reviewing this notice, please call customer service at 574-371-3071 between 8:00 am and 5:00pm EST, Monday through Friday. Calls received outside of call center operating hours will receive a voicemail prompt or be transferred to an on-call representative in the event of an emergency. Alternatively, your questions may be emailed to CorporateQuality.PostMarket@zimmerbiomet.com.\n\nSurgeon Responsibilities:\n1. Review this notification for awareness of the contents.\n2. There are no specific patient monitoring instructions related to this recall that are recommended beyond your existing follow-up schedule.",
      "product_quantity": "412 units total",
      "distribution_pattern": "US Nationwide",
      "openfda": {
        "k_number": [
          "K980486",
          "K905275",
          "K110290",
          "K240783",
          "K912593",
          "K871462",
          "K012493",
          "K922866",
          "K844028",
          "K982963",
          "K961799",
          "K913874",
          "K942966",
          "K050637",
          "K972995",
          "K880461",
          "K934857",
          "K142295",
          "K821714",
          "K920286",
          "K883460",
          "K960302",
          "K971681",
          "K821713",
          "K884027",
          "K130610",
          "K873999",
          "K860002",
          "K982598",
          "K912916",
          "K800487",
          "K964218",
          "K961890",
          "K901297",
          "K883618",
          "K972961",
          "K974685",
          "K903630",
          "K905406",
          "K832211",
          "K032396",
          "K951139",
          "K904919",
          "K002757",
          "K000817",
          "K905408",
          "K001759",
          "K812801",
          "K950418",
          "K203815",
          "K811293",
          "K983128",
          "K962560",
          "K955354",
          "K881117",
          "K905298",
          "K882869",
          "K830313",
          "K880004",
          "K031474",
          "K200823",
          "K861930",
          "K955620",
          "K902137",
          "K983136",
          "K042959",
          "K880435",
          "K953200",
          "K022094",
          "K991869",
          "K031734",
          "K953578",
          "K203588",
          "K051516",
          "K001956",
          "K810120",
          "K993713",
          "K160923",
          "K871401",
          "K881769",
          "K935585",
          "K992153",
          "K022958",
          "K984154",
          "K153057",
          "K020076",
          "K972791",
          "K964350",
          "K853169",
          "K874599",
          "K936127",
          "K090998",
          "K953025",
          "K021380",
          "K953033",
          "K852839",
          "K800894",
          "K900836",
          "K933561",
          "K900891",
          "K930460",
          "K823725",
          "K962267",
          "K920161",
          "K904207",
          "K912426",
          "K120578",
          "K001932",
          "K023085",
          "K031744",
          "K952191",
          "K920003",
          "K922863",
          "K831314",
          "K930108",
          "K844050",
          "K860701",
          "K830948",
          "K022077",
          "K980794",
          "K884890",
          "K830356",
          "K030867",
          "K843909",
          "K852517",
          "K884888",
          "K953202",
          "K930771",
          "K803126",
          "K930275",
          "K915216",
          "K864857",
          "K913060",
          "K911052",
          "K883724",
          "K952970",
          "K972435",
          "K871852",
          "K842906",
          "K920640",
          "K873585",
          "K844319",
          "K003421",
          "K920021",
          "K914406",
          "K923243",
          "K020989",
          "K870922",
          "K922862",
          "K950761",
          "K022799",
          "K885338",
          "K980286",
          "K991538",
          "K940328",
          "K830314",
          "K974054",
          "K181340",
          "K191449",
          "K973453",
          "K896851",
          "K942406",
          "K980626",
          "K240418",
          "K902727",
          "K915594",
          "K111848",
          "K003666",
          "K012961",
          "K930812",
          "K904844",
          "K070364",
          "K920317",
          "K882146",
          "K900438",
          "K142761",
          "K874093",
          "K020970",
          "K884432",
          "K011887",
          "K955296",
          "K872856",
          "K010310",
          "K873857",
          "K023453",
          "K193429",
          "K895035",
          "K862225",
          "K770908",
          "K855017",
          "K910093",
          "K961899",
          "K052639",
          "K061344",
          "K162125",
          "K990032",
          "K913208",
          "K904737",
          "K980513",
          "K901328",
          "K935012",
          "K910988",
          "K844787",
          "K030153",
          "K831373",
          "K233261",
          "K063278",
          "K972460",
          "K080539",
          "K894149",
          "K001078",
          "K901240",
          "K960258",
          "K990330",
          "K920250",
          "K884457",
          "K010757",
          "K952629",
          "K940307",
          "K842202",
          "K901460",
          "K010529",
          "K905158",
          "K983710",
          "K813600",
          "K844817",
          "K024340",
          "K121055",
          "K960425",
          "K871510",
          "K821066",
          "K011774",
          "K901087",
          "K964262",
          "K903362",
          "K943549",
          "K123598",
          "K913231",
          "K960626",
          "K903116",
          "K870216",
          "K901364",
          "K213701",
          "K123501",
          "K974558",
          "K936214",
          "K971890",
          "K905258",
          "K936043",
          "K082239",
          "K871299",
          "K812182",
          "K032730",
          "K220216",
          "K963206",
          "K890742",
          "K872732",
          "K991987",
          "K960025",
          "K933875",
          "K823727",
          "K945774",
          "K210842",
          "K001376",
          "K870235",
          "K905262",
          "K883941",
          "K913616",
          "K840357",
          "K926323",
          "K003976",
          "K904351",
          "K874229",
          "K852153",
          "K033871",
          "K834035",
          "K051407",
          "K935263",
          "K822979",
          "K951084",
          "K253434",
          "K841391",
          "K870699",
          "K870128",
          "K911890",
          "K002106",
          "K852546",
          "K031730",
          "K921383",
          "K831884",
          "K191414",
          "K922008",
          "K830750",
          "K871347",
          "K832958",
          "K992409",
          "K980813",
          "K960658",
          "K920430",
          "K923275",
          "K013352",
          "K924323",
          "K915500",
          "K963671",
          "K955473",
          "K862234",
          "K982670",
          "K890649",
          "K241716",
          "K885192",
          "K823722",
          "K973809",
          "K962468",
          "K910922",
          "K902436",
          "K991622",
          "K821369",
          "K902961",
          "K932574",
          "K000254",
          "K050441",
          "K222056",
          "K922871",
          "K790488",
          "K920639",
          "K894148",
          "K971581",
          "K910869",
          "K952731",
          "K903243",
          "K874616",
          "K882812",
          "K911684",
          "K932481",
          "K180973",
          "K893821",
          "K911685",
          "K823419",
          "K990821",
          "K823723",
          "K911058",
          "K930187",
          "K994007",
          "K954262",
          "K960647",
          "K973296",
          "K963612",
          "K853916",
          "K813089",
          "K925201",
          "K952461",
          "K861433",
          "K960151",
          "K203090",
          "K922503",
          "K900257",
          "K924115",
          "K803074",
          "K903242",
          "K853768",
          "K895636",
          "K922847",
          "K960156",
          "K972641",
          "K901451",
          "K861988",
          "K910662",
          "K964795",
          "K852585",
          "K913649",
          "K890498",
          "K070399",
          "K011218",
          "K935449",
          "K992490",
          "K853886",
          "K831986",
          "K992058",
          "K945574",
          "K970351",
          "K943696",
          "K012026",
          "K840643",
          "K111863",
          "K901480",
          "K853655",
          "K895036",
          "K152621",
          "K243571",
          "K954219",
          "K960678",
          "K954598",
          "K830004",
          "K936126",
          "K891454",
          "K902395",
          "K922733",
          "K830361",
          "K051569",
          "K894298",
          "K861979",
          "K001335",
          "K982918",
          "K962086",
          "K861114",
          "K903636",
          "K913634",
          "K922860",
          "K870445",
          "K925895",
          "K942611",
          "K142814",
          "K943302",
          "K191056",
          "K021178",
          "K914878",
          "K970194",
          "K963486",
          "K874619",
          "K946371",
          "K903234",
          "K830857",
          "K830209",
          "K952859",
          "K961304",
          "K914078",
          "K890054",
          "K965019",
          "K080885",
          "K935206",
          "K955137",
          "K021310",
          "K990369",
          "K002324",
          "K972792",
          "K880269",
          "K913812",
          "K920739",
          "K923898",
          "K050138",
          "K950312",
          "K052748",
          "K960278",
          "K964003",
          "K911802",
          "K802872",
          "K153725",
          "K845005",
          "K823724",
          "K945115",
          "K963109",
          "K960339",
          "K023646",
          "K833912",
          "K896325",
          "K051363",
          "K912712",
          "K991227",
          "K922645",
          "K011455",
          "K922864",
          "K811151",
          "K052792",
          "K880390",
          "K802627",
          "K942537",
          "K011715",
          "K082792",
          "K021822",
          "K913246",
          "K853408",
          "K933281",
          "K141331",
          "K852705",
          "K925348",
          "K935951",
          "K012019",
          "K914675",
          "K922421",
          "K191735",
          "K961619",
          "K894249",
          "K011623",
          "K072857",
          "K823728",
          "K013350",
          "K941486",
          "K213816",
          "K121056",
          "K903938",
          "K030766",
          "K910836",
          "K854465",
          "K963313",
          "K863184",
          "K840150",
          "K873632",
          "K780052",
          "K020291",
          "K992903",
          "K843190",
          "K001571",
          "K873626",
          "K855200",
          "K903635",
          "K854046",
          "K983226",
          "K093646",
          "K141370",
          "K050105",
          "K090208",
          "K951726",
          "K960340",
          "K871867",
          "K003975",
          "K925866",
          "K926229",
          "K201519",
          "K821893",
          "K034028",
          "K954744",
          "K971705",
          "K871857",
          "K960984",
          "K942370",
          "K011367",
          "K823729",
          "K980926",
          "K844941",
          "K970697",
          "K902279",
          "K001733",
          "K934169",
          "K051335",
          "K881128",
          "K780317",
          "K964655",
          "K252824",
          "K903957",
          "K902396",
          "K930223",
          "K936132",
          "K984227",
          "K902621",
          "K941617",
          "K915795",
          "K871402",
          "K030265",
          "K911718",
          "K031165",
          "K900261",
          "K910352",
          "K780398",
          "K153216",
          "K980843",
          "K864999",
          "K802342",
          "K833881",
          "K981855",
          "K972928",
          "K944792",
          "K842360",
          "K900832",
          "K851422"
        ],
        "registration_number": [
          "1834331",
          "3005360851",
          "3019807891",
          "1221053",
          "3003541440",
          "1526534",
          "3017397663",
          "3004513872",
          "3009760038",
          "2242737",
          "3016438694",
          "1720929",
          "2245304",
          "3018094310",
          "3002807315",
          "3009546990",
          "3010536692",
          "3014763043",
          "2528981",
          "8010379",
          "9614209",
          "1828464",
          "3008572101",
          "3003998208",
          "1722511",
          "3010041993",
          "3005581234",
          "3011170410",
          "3006395932",
          "3000196378",
          "3010363503",
          "3005323511",
          "3009732568",
          "1000547811",
          "9613350",
          "1057425",
          "3004371426",
          "1822565",
          "3004641308",
          "3004153896",
          "9681642",
          "3006356043",
          "3010041693",
          "3008110533",
          "3006801265",
          "1833920",
          "3013176080",
          "3015516266",
          "3011683674",
          "3003595343",
          "8044172",
          "1835251",
          "3010288357",
          "3002806535",
          "3015167917",
          "1827096",
          "3007366790",
          "3012130008",
          "3012319330",
          "2249697",
          "1721676",
          "3009241418",
          "1649518",
          "3008556682",
          "1424263",
          "3010386387",
          "3015398319",
          "3007311878",
          "3001278222",
          "3020155054",
          "3026771806",
          "3004635447",
          "1643264",
          "9610612",
          "9610726",
          "8010916",
          "9616680",
          "3005061536",
          "2134285",
          "1818910",
          "3010220595",
          "3015259876",
          "1643817",
          "3038503932",
          "3013450937",
          "3036756245",
          "3009106092",
          "1834379",
          "3007913880",
          "3002806470",
          "3006085220",
          "3012523063",
          "3008812251",
          "2648920",
          "3013086329",
          "3010287737",
          "3009882462",
          "3002808022",
          "3013014058",
          "3005180920",
          "1220477",
          "3043543260",
          "9616944",
          "3006128100",
          "1058584",
          "3009959868",
          "3002807310",
          "3009888740",
          "3011277306",
          "2246552",
          "3010097171",
          "3008262872",
          "3006809628",
          "3025603301",
          "3008102042",
          "3003761012",
          "3002806603",
          "3033509898",
          "3005751028",
          "1226544",
          "1833986",
          "3011295718",
          "3003387384",
          "3004180226",
          "2030624",
          "3009973336",
          "3022142628",
          "2249615",
          "3002807090",
          "1000550978",
          "3014252644",
          "3021008900",
          "3010468876",
          "3010314800",
          "1645151",
          "3009973505",
          "3035366890",
          "3013302242",
          "3007923096",
          "3005551626",
          "1221763",
          "9616671",
          "3002807295",
          "3009173317",
          "1038671",
          "2531477",
          "9681465",
          "3010065126",
          "3014302784",
          "3004142400",
          "3011015572",
          "8043792",
          "2011171",
          "3010132111",
          "2244478",
          "3006017180",
          "3010178296",
          "1824199",
          "1649390",
          "1825034",
          "1828288",
          "9613369",
          "3010120135",
          "3007189546",
          "3000236920",
          "1000200989",
          "3005718816",
          "1219655",
          "1020279",
          "3004748528",
          "3008868758",
          "3020162561",
          "1047843",
          "2133928",
          "3012329926",
          "3002907620",
          "3010155648",
          "3011274144",
          "3036773273",
          "3018052045",
          "3010173425",
          "3027484613",
          "3017410889",
          "3002807314",
          "3008281151",
          "3003639920",
          "3020282716",
          "3000258338",
          "3006946279",
          "3030412764",
          "1833506",
          "1043653",
          "3009475821",
          "1529009",
          "3010163695",
          "3014644608",
          "3010846112",
          "1531174",
          "3016851379",
          "3012392319",
          "3015542154",
          "3013055499",
          "3012725451",
          "3023852420",
          "1423662",
          "3042508254",
          "1030489",
          "3007740680",
          "3009998573",
          "3009871135",
          "3007200272",
          "1018470",
          "3010057495",
          "1450662",
          "1220246",
          "3010039400",
          "3020967480",
          "1836357",
          "3008021110",
          "3009756327",
          "3008395353",
          "1644408",
          "3015207155",
          "3005562917",
          "3000931034",
          "1526350"
        ],
        "fei_number": [
          "3005360851",
          "3019807891",
          "1221053",
          "3000718467",
          "3003541440",
          "1000118610",
          "1526534",
          "3017397663",
          "1000199976",
          "3004513872",
          "1000132037",
          "3001236277",
          "3009760038",
          "3016438694",
          "1720929",
          "2245304",
          "3018094310",
          "3002807315",
          "1000086912",
          "3009546990",
          "3010536692",
          "3014763043",
          "3005985723",
          "2528981",
          "1000395711",
          "1828464",
          "3008572101",
          "3003998208",
          "3010041993",
          "3005581234",
          "3011170410",
          "3006395932",
          "1000143502",
          "1000149660",
          "3000196378",
          "3010363503",
          "3005323511",
          "3009732568",
          "1000547811",
          "3000215273",
          "3004641308",
          "3004153896",
          "3006356043",
          "3010041693",
          "3003569173",
          "3008110533",
          "3006801265",
          "3013176080",
          "3015516266",
          "3001049282",
          "3011683674",
          "3002993297",
          "3003595343",
          "3010288357",
          "3002806535",
          "3015167917",
          "1827096",
          "3000206435",
          "3012130008",
          "3012319330",
          "1721676",
          "3009241418",
          "1000220733",
          "3002924544",
          "3008556682",
          "3001598088",
          "3010386387",
          "3007311878",
          "3001278222",
          "3020155054",
          "3026771806",
          "1000219637",
          "3004635447",
          "1643264",
          "3005061536",
          "1818910",
          "3010220595",
          "3015259876",
          "1643817",
          "3038503932",
          "3013450937",
          "3036756245",
          "3009106092",
          "3007913880",
          "3002806470",
          "3006085220",
          "3002806725",
          "3012523063",
          "3013086329",
          "3006003617",
          "3002806315",
          "3002806653",
          "3010287737",
          "3009882462",
          "3002808022",
          "3013014058",
          "3005180920",
          "1220477",
          "3043543260",
          "3006128100",
          "3011277306",
          "3009959868",
          "3002807310",
          "3009888740",
          "2246552",
          "3003015552",
          "3010097171",
          "3008262872",
          "1000306340",
          "1000139987",
          "3006809628",
          "3025603301",
          "3003761012",
          "3002806603",
          "3033509898",
          "3005751028",
          "3002807113",
          "3011295718",
          "3003387384",
          "3003070421",
          "3009973336",
          "1000221916",
          "3002807893",
          "3022142628",
          "1000550978",
          "3014252644",
          "3007282753",
          "1000136269",
          "3021008900",
          "3010314800",
          "3001642380",
          "3000717902",
          "3009973505",
          "3035366890",
          "3013302242",
          "3007923096",
          "1832656",
          "3005551626",
          "1221763",
          "3002807295",
          "3009173317",
          "1038671",
          "3000205591",
          "3010065126",
          "3014302784",
          "3005601732",
          "3011015572",
          "2011171",
          "3010132111",
          "3002287318",
          "3007932279",
          "3001548076",
          "3006017180",
          "1824199",
          "1825034",
          "1000306303",
          "1828288",
          "3010120135",
          "3007189546",
          "3003110073",
          "1000200989",
          "3005718816",
          "1219655",
          "1020279",
          "3004748528",
          "3008868758",
          "3002807036",
          "3002807038",
          "3020162561",
          "1047843",
          "3012329926",
          "3002907620",
          "3010155648",
          "3011274144",
          "3036773273",
          "3018052045",
          "3002854251",
          "3027484613",
          "3003386935",
          "3002807314",
          "3008281151",
          "3003639920",
          "3002808269",
          "3020282716",
          "3005233524",
          "1000477302",
          "3000258338",
          "3006946279",
          "1000115656",
          "3030412764",
          "3002807172",
          "3003128516",
          "1043653",
          "3009475821",
          "3010163695",
          "3002459190",
          "3014644608",
          "3010846112",
          "3015542154",
          "3016851379",
          "3012392319",
          "3004142400",
          "3013055499",
          "3012725451",
          "3002808293",
          "3023852420",
          "3042508254",
          "1000116912",
          "3007740680",
          "3009998573",
          "3009871135",
          "3007200272",
          "1018470",
          "3010057495",
          "1450662",
          "1220246",
          "3010039400",
          "3020967480",
          "3008021110",
          "3008395353",
          "3015207155",
          "3005562917",
          "3003064967",
          "3000931034",
          "1526350",
          "3003414678"
        ],
        "device_name": "Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented",
        "medical_specialty_description": "Orthopedic",
        "regulation_number": "888.3350",
        "device_class": "2"
      }
    }
  ]
}