      "cfres_id": "176934",
      "product_res_number": "Z-0597-2020",
      "event_date_initiated": "2017-08-15",
      "event_date_created": "2019-12-03",
      "recall_status": "Terminated",
      "event_date_terminated": "2020-05-05",
      "res_event_number": "83992",
      "product_code": "BTY",
      "k_numbers": [
        "K161534"
      ],
      "product_description": "EasyOne Pro LAB VOS Respiratory Analysis System Pulmonary Function Testing Device, Model 3100-1",
      "code_info": "Serial Numbers: 650074 650085 650075 650086 650076 650087 650079 650088 650080 650089 650081 650090 650082 650091 650083 650092 650094 650095 650096 650098 650099 650100 650104 650055 650058 650062 650066 650067 650069 650070 650073",
      "firm_fei_number": "3002918917",
      "recalling_firm": "NDDd Medical Technologies, Inc.",
      "address_1": "2 Dundee Park Dr",
      "city": "Andover",
      "state": "MA",
      "postal_code": "01810-3735",
      "additional_info_contact": "Robert Weisman\n978-470-0923 Ext. 123",
      "reason_for_recall": "The CO/CO2 sensor cable harness may have lower electromagnetic shielding, which might have resulted in a non-compliance with the IEC 60601-1-2 standard.  As a consequence of a lower electromagnetic shielding provided by the cable harness, the CO/CO2 sensor could have been influenced by high frequencies emitted by very close devices.",
      "root_cause_description": "Component change control",
      "action": "Customers were contacted via email or telephone between 8/1/17 and 4/13/19.\n\nThe emails including the following information:\n\nWe wanted to inform you that we are planning a preventive repair for some of our recently delivered EasyOne\nPro/LAB V05 devices. The repair is related to an internal shielding component against electromagnetic disturbances.\nIn some rare cases this could potentially lead to DLCO or MBW that cannot be performed. Although the probability of\noccurrence is very low, we want to absolutely ensure the quality of our devices and therefore we would like to make\narrangements to update the shielding of this affected device. It is important to note, that all costs regarding the\nnecessary repair will be covered by ndd, including all potential expenses.\nI would like to discuss handling of the repair and covering of the cost at the time of the repair.\nOf course, we already ensured that all newly delivered devices are not affected by the shielding issue. You can\ntherefore order devices normally, there is no special action required.\nWe are very sorry for the inconvenience this might be causing you as well as our shared customers and are\ncommitted to help as much as possible to ensure a smooth exchange of the affected component.\nCan you please contact me so we can make arrangements?",
      "product_quantity": "37 total devices",
      "distribution_pattern": "The products were distributed to the following US states:  KY, MO, NY, OH, PA",
      "openfda": {
        "k_number": [
          "K812850",
          "K223629",
          "K921309",
          "K242809",
          "K892705",
          "K854745",
          "K190800",
          "K111053",
          "K932278",
          "K855068",
          "K911358",
          "K993641",
          "K120635",
          "K864087",
          "K222982",
          "K823683",
          "K231561",
          "K090722",
          "K961252",
          "K091428",
          "K864836",
          "K790579",
          "K150888",
          "K062011",
          "K780584",
          "K031194",
          "K173937",
          "K980094",
          "K040549",
          "K113813",
          "K853433",
          "K930085",
          "K933839",
          "K942230",
          "K082539",
          "K181912",
          "K883008",
          "K803053",
          "K981366",
          "K881122",
          "K071753",
          "K080510",
          "K020745",
          "K161534",
          "K861486",
          "K821712",
          "K894667",
          "K080734",
          "K823771",
          "K810712",
          "K812849",
          "K122699",
          "K932744",
          "K855069",
          "K850045",
          "K942211",
          "K000648",
          "K202754",
          "K933511",
          "K812792",
          "K221030",
          "K863087",
          "K861487"
        ],
        "registration_number": [
          "1000154583",
          "8021084",
          "8030673",
          "3008072932",
          "2183022",
          "2134715",
          "3033959233",
          "3030308442",
          "9615102",
          "3002808458",
          "1314417",
          "3016218294",
          "2433214",
          "3037873864",
          "3010594620",
          "9680276",
          "9614485",
          "3008505660"
        ],
        "fei_number": [
          "1000154583",
          "3002673652",
          "3003007937",
          "3010320336",
          "3008072932",
          "3010594620",
          "2183022",
          "3033959233",
          "3030308442",
          "3002808458",
          "3016218294",
          "2433214",
          "2995",
          "3037873864",
          "1314417",
          "3004213967",
          "1000271197",
          "3008505660"
        ],
        "device_name": "Calculator, Predicted Values, Pulmonary Function",
        "medical_specialty_description": "Anesthesiology",
        "regulation_number": "868.1890",
        "device_class": "2"
      }
    }
  ]
}