  "results": [
    {
      "cfres_id": "170373",
      "product_res_number": "Z-0807-2019",
      "event_date_initiated": "2019-01-17",
      "event_date_posted": "2019-02-14",
      "recall_status": "Open, Classified",
      "res_event_number": "81945",
      "product_code": "NVZ",
      "pma_numbers": [
        "P980035"
      ],
      "product_description": "Medtronic implantable pulse generator:  ATTESTA L DR MRI SureScan, Dual chamber rate responsive pacemaker (DDDR): \n(a) Model Number ATDR01\n(b) Model Number ATDRL1\n(c) Model Number ATDRS1",
      "code_info": "ATTESTA L DR MRI SureScan, Dual chamber rate responsive pacemaker (DDDR):  (a) Model Number ATDR01, GTIN:  00643169882911, 00763000109059, All Serial Numbers  (b) Model Number ATDRL1, GTIN:  00643169882928, 00763000109066, All Serial Numbers  (c) Model Number ATDRS1, GTIN:  00643169882935, 00763000109073, All Serial Numbers",
      "firm_fei_number": "2182208",
      "recalling_firm": "Medtronic Inc., Cardiac Rhythm and Heart Failure (CRHF)",
      "address_1": "8200 Coral Sea St Ne",
      "city": "Mounds View",
      "state": "MN",
      "postal_code": "55112-4391",
      "additional_info_contact": "Technical Services\n800-505-4636",
      "reason_for_recall": "A  subset of Medtronic dual chamber pacemakers distributed worldwide between 10 March 2017 and 7 January 2019 under the brand names Adapta, Versa, and Sensia when programmed to a dual chamber mode with atrial-sensing, may experience a circuit error that affects device functionality",
      "root_cause_description": "Component design/selection",
      "action": "In the US, beginning 17-Jan-2019, Medtronic Field Representatives hand deliver an FCA Notification Letter to consignees including implanting and follow-up physicians. In consultation with an Independent Physician Quality Panel (IPQP), patient management recommendations were provided with the FCA Notification letter to ensure patient safety.\n\nMedtronic Field Representatives will hand deliver an additional Supplemental Letter with the Urgent Medical Device Recall letter to a subset of physicians with patients whose device has shown evidence of a pacing pause that is potentially related to this circuit error. Consignees will be asked to return all unused and unopened affected product to Medtronic.",
      "product_quantity": "9915 units",
      "distribution_pattern": "Wordlwide",
      "openfda": {
        "pma_number": [
          "P930022",
          "P830045",
          "P880038",
          "P890003",
          "P960013",
          "P910023",
          "P950037",
          "P880006",
          "P950029",
          "P980035",
          "P010031",
          "P010015",
          "P900070",
          "P970012",
          "P990001",
          "P880086"
        ],
        "registration_number": [
          "3018094310",
          "2649622",
          "3013500228",
          "9614453",
          "9610139",
          "1028232",
          "1000165971",
          "3012552532",
          "3013288201",
          "3008483389",
          "3004593495",
          "3003120897",
          "3005334138",
          "2182208",
          "2030624",
          "3009144177",
          "3008159616",
          "2024024",
          "3015453963",
          "3002806603",
          "3011120183",
          "2133641",
          "3009380063",
          "2032521",
          "3008973940",
          "3005941719",
          "2017865",
          "3013596024",
          "3006705815",
          "3033257494",
          "1220452",
          "3008494315",
          "2135338",
          "2124215",
          "3004209178"
        ],
        "fei_number": [
          "3018094310",
          "3000203466",
          "2649622",
          "3013500228",
          "1028232",
          "3003574398",
          "3002807576",
          "1000165971",
          "3012552532",
          "3013288201",
          "3008483389",
          "3008377825",
          "3004593495",
          "3003120897",
          "3005334138",
          "2182208",
          "3009144177",
          "3000206435",
          "3008159616",
          "2024024",
          "3015453963",
          "3002806603",
          "3011120183",
          "3004369318",
          "3002807111",
          "3009380063",
          "3008973940",
          "2017865",
          "3013596024",
          "3006705815",
          "3033257494",
          "1220452",
          "3002806500",
          "3005700659",
          "2124215"
        ],
        "device_name": "Pulse Generator, Permanent, Implantable",
        "medical_specialty_description": "Unknown",
        "regulation_number": "",
        "device_class": "3"
      }
    }
  ]
}