  "results": [
    {
      "cfres_id": "169254",
      "product_res_number": "Z-0659-2019",
      "event_date_initiated": "2018-11-08",
      "event_date_created": "2018-12-21",
      "recall_status": "Terminated",
      "event_date_terminated": "2021-07-23",
      "res_event_number": "81649",
      "product_code": "IXY",
      "product_description": "Bucky Stand SU-4000 Input 2017.11.17.\nSU41711085\nDate: 2017-11-17; Board Name; Board Version, Firmware Version\n\nAdvanced Universal U-Arm 4000 System.\nThe Positioner consists of the following associated subassemblies: Vertical Column, Swivel Arm with variable\nheight, X-ray Tube, Automatic Exposure Control, Collimator, Touch Screen Control and Image Receptor Assembly.\nThe Positioner and the Patient Mobile Table are associated equipment to the Generator X-ray Unit.",
      "code_info": "SU4000 AU 4000 U ARM Item Number DR-4000-MTB  Serials Numbers/Lot Numbers: SU41607003; SU41607004; SU41607005; SU41607006; SU41607008; SU41607009; SU41607010; SU41607011; SU41612012; SU41612013; SU41612014; SU41612015; SU41612016; SU41612017; SU41612018; SU41612019; SU41612020; SU41612021; SU41702006; SU41702007; SU41702009; SU41703010; SU41703011; SU41703012; SU41703013; SU41703015; SU41704016; SU41704017; SU41704019; SU41704020; SU41704021; SU41704022; SU41704023; SU41704024; SU41704025; SU41705026; SU41705027; SU41705028; SU41705029; SU41705031; SU41705032; SU41705033; SU41705034; SU41705035; SU41707036; SU41707038; SU41707039; SU41707040; SU41707041; SU41707042; SU41707043; SU41707044; SU41708046; SU41708047; SU41708048; SU41708049; SU41708050; SU41708051; SU41708052; SU41708053; SU41708054; SU41708055; SU41709060; SU41709061; SU41709062; SU41709063; SU41709064; SU41709065; SU41709066; SU41709068; SU41709069; SU41711070; SU41711071; SU41711072; SU41711073; SU41711074; SU41711075; SU41711076; SU41711077; SU41711079; SU41711080; SU41711081; SU41711082; SU41711083; SU41711084; SU41711085; SU41711086; SU41711087; SU41711088; SU41711089; SU41712090; SU41712093; SU41712094; SU41712095; SU41712096; SU41712097; SU41712098; SU41712099; SU4172091; SU41801001; SU41801002; SU41801003; SU41801004; SU41801005; SU41802006; SU41802007; SU41802008; SU41802009; SU41802010; SU41802011; SU41802012; SU41802013; SU41802014; SU41802015; SU41802016; SU41802017; SU41802018; SU41802019; SU41802020; SU41803021; SU41803022; SU41803023; SU41803024; SU41803025; SU41803026; SU41803028; SU41803029; SU41803030; SU41803031; SU41803032; SU41803033; SU41803034; SU41803035; SU41803037; SU41803038; SU41803039; SU41803040; SU41806041; SU41806042; SU41806043; SU41806044; SU41808047; SU41808048; SU41808049; SU41808050; SU41808053; SU41808054; SU41808055; SU41808058; SU41808060; SU41808063; SU41808064",
      "firm_fei_number": "3002885429",
      "recalling_firm": "Konica Minolta Healthcare, Americas, Inc.",
      "address_1": "2217 US Highway 70 E",
      "city": "Garner",
      "state": "NC",
      "postal_code": "27529-9424",
      "additional_info_contact": "Konica Minolta Customer Care Team\n800-945-0456",
      "reason_for_recall": "Unintentional U-Arm movement",
      "root_cause_description": "Device Design",
      "action": "On 11/08/2018, the firm send a letter titled;\" IMPORTANT PRODUCT INFORMATION\", regarding the Konica Minolta KDR U-Arm.  Potential unintentional U-Arm movement due to the tablet enclosure buttons, located on the tablet enclosure, remaining engaged after being depressed.\n\nThe firm included a document titled, KDR U-ARM Tablet Enclosure FAQ as part of the IMPORTANT PRODUCT INFORMATION.  The firm is preparing to issue an Interim Corrective Action; Disabling the buttons contained on the KDR tablet enclosure and a Final Corrective Action; A modification to the mounting of the PCB - which contains the drive buttons will reduce the potential of the event -this will help assure the buttons make the proper contact without staying depressed.\n\nIn addition, the firm issued a \"Technical Bulletin-Business Partner for the Product: KDR U-Arm Tablet Enclosure.\"  The preliminary notification was sent to dealer partners which require all Partners to take immediate action.\nThere are two critical actions needed to mitigate this risk:\n\n1.\tInterim Action (Immediate Action Required):\nThe firm has released an immediate field corrective action to temporarily disconnect the tablet enclosure buttons. Instructions can be found in KON-000127 .\n\n2.\tFinal Action (Anticipated Release January 2019):\nA modification to the tablet design will help ensure the buttons make the proper contact without staying depressed.\n\nThe Interim Action/Field Correction is required to be completed by December 15, 2018.\n \n\nContact Konica Minolta Dispatch department at 1- 800-945-0456 to schedule a Konica Minolta Engineer to complete Corrective action. For each affected unit, it is important that your engineer performs the following:\n\n1.  Complete the Tablet Button Disconnection procedure - KON-000127\n2.\tFill out form KON-000157 (Customer Signature required)\n3.\tTake a picture of the completed form KON-000157 and email to ServiceBilling@gcp.konicaminolta .com.",
      "product_quantity": "151",
      "distribution_pattern": "US Nationwide Distribution: AL; CA; CO; FL; GA; IA; IL; IN; KY; LA; MA; MI; MN; MO; NC; NH; NY; OH; OK; PA; SC; TN; TX; and VA.",
      "openfda": {
        "k_number": [
          "K872132",
          "K895034",
          "K946114",
          "K891395",
          "K930249",
          "K790742",
          "K862828",
          "K924445",
          "K953336",
          "K853756",
          "K946260",
          "K791916",
          "K953402",
          "K810194",
          "K860454",
          "K915667",
          "K925934",
          "K922443",
          "K930230",
          "K850125",
          "K851440"
        ],
        "registration_number": [
          "3014209556",
          "3005920099",
          "3005778458",
          "3005172103",
          "1724615",
          "3003768251",
          "3000126629",
          "9613445",
          "1418964",
          "3006551157",
          "3003102481",
          "2243057",
          "3003202425",
          "1450835",
          "3001556265",
          "3014403439",
          "9616014",
          "3010656982",
          "9710585",
          "1450503",
          "2431224",
          "3008284470",
          "3015276580",
          "3004756607",
          "3002466018",
          "9610903",
          "3013677815",
          "9617251",
          "8030233",
          "3029916061",
          "2436865",
          "3008141750"
        ],
        "fei_number": [
          "3002808139",
          "3014209556",
          "3005920099",
          "3002175190",
          "3005778458",
          "3005172103",
          "3003768251",
          "3000126629",
          "1000521490",
          "3002495042",
          "1418964",
          "3006551157",
          "3003102481",
          "3002807145",
          "2243057",
          "3003202425",
          "1450835",
          "3001556265",
          "3014403439",
          "1000396729",
          "3010656982",
          "1450503",
          "3002675731",
          "2431224",
          "3008284470",
          "3015276580",
          "3004756607",
          "3002466018",
          "3013677815",
          "3001620005",
          "3029916061",
          "3008141750"
        ],
        "device_name": "Holder, Radiographic Cassette, Wall-Mounted",
        "medical_specialty_description": "Radiology",
        "regulation_number": "892.1880",
        "device_class": "1"
      }
    }
  ]
}