      "cfres_id": "160827",
      "product_res_number": "Z-0380-2018",
      "event_date_initiated": "2017-07-17",
      "event_date_created": "2018-01-17",
      "recall_status": "Terminated",
      "event_date_terminated": "2018-08-29",
      "res_event_number": "78900",
      "product_code": "MUJ",
      "k_numbers": [
        "K171536"
      ],
      "product_description": "RayStation \n\nProduct Usage:  is a software system designed for treatment planning and analysis of radiation therapy. The treatment plans provide treatment unit set-up parameters and estimates of dose distributions expected during the proposed treatment, and may be used to administer treatments after review and approval by the intended user.",
      "code_info": "6.0.0.24 ,  6.1.0.26 ,  6.1.1.2  or  6.2.0.7",
      "firm_fei_number": "3007774465",
      "recalling_firm": "RAYSEARCH LABORATORIES AB",
      "address_1": "Sveavaegen 9 9 sveavaegen",
      "city": "Stockholm",
      "country": "Sweden",
      "reason_for_recall": "For the proton QA preparation module in RayStation 6 (including SP1 and SP2), if the snout position or gap is modified in the QA module, the dose in the QA module may be computed for a different setup than what is used for QA measurements. This could result in an incorrect dosage being provided to a patient.",
      "root_cause_description": "Device Design",
      "action": "Ray Search sent a Field Safety Notice letter dated July 14, 2017 to affected customers.  The letter identified the affected product, problem and actions to be taken.  The letter included a response form with instructions for workarounds until the software is corrected.",
      "product_quantity": "117 units",
      "distribution_pattern": "US Nationwide Distribution - FL, WA, AZ, TN, MD, TX, FL, MI, Washington D.C.",
      "openfda": {
        "k_number": [
          "K132971",
          "K091179",
          "K982696",
          "K915691",
          "K211379",
          "K232400",
          "K171885",
          "K201444",
          "K982791",
          "K252304",
          "K012017",
          "K242992",
          "K211034",
          "K142108",
          "K041403",
          "K011246",
          "K041719",
          "K100056",
          "K160093",
          "K983343",
          "K180379",
          "K123263",
          "K051497",
          "K022036",
          "K991815",
          "K211841",
          "K260308",
          "K042269",
          "K100417",
          "K220783",
          "K082221",
          "K051941",
          "K100552",
          "K002312",
          "K201607",
          "K223279",
          "K151666",
          "K032724",
          "K210645",
          "K984532",
          "K150547",
          "K993675",
          "K133331",
          "K112723",
          "K081281",
          "K013112",
          "K211511",
          "K253078",
          "K994413",
          "K202789",
          "K013673",
          "K992762",
          "K090972",
          "K240671",
          "K182665",
          "K083264",
          "K133247",
          "K041971",
          "K192065",
          "K010682",
          "K022411",
          "K090531",
          "K151560",
          "K170086",
          "K090182",
          "K151887",
          "K002147",
          "K172163",
          "K252109",
          "K203469",
          "K032345",
          "K190664",
          "K063482",
          "K002509",
          "K080888",
          "K133655",
          "K111311",
          "K151380",
          "K213438",
          "K162370",
          "K220582",
          "K101076",
          "K991237",
          "K061097",
          "K200569",
          "K213787",
          "K250963",
          "K091146",
          "K193109",
          "K974770",
          "K042739",
          "K202284",
          "K092132",
          "K112060",
          "K081112",
          "K141283",
          "K091492",
          "K113102",
          "K022307",
          "K102216",
          "K042861",
          "K063230",
          "K020027",
          "K170750",
          "K061440",
          "K120363",
          "K200608",
          "K220141",
          "K241318",
          "K012575",
          "K123152",
          "K242748",
          "K232799",
          "K252002",
          "K022741",
          "K031349",
          "K062967",
          "K121448",
          "K152393",
          "K141860",
          "K173940",
          "K992864",
          "K013644",
          "K222312",
          "K100092",
          "K203766",
          "K242378",
          "K193640",
          "K252863",
          "K243057",
          "K222803",
          "K990475",
          "K032456",
          "K040474",
          "K253050",
          "K993766",
          "K140187",
          "K161136",
          "K131891",
          "K141900",
          "K200487",
          "K050296",
          "K103093",
          "K071938",
          "K082005",
          "K083414",
          "K203681",
          "K001295",
          "K993923",
          "K182888",
          "K021268",
          "K123357",
          "K993895",
          "K151435",
          "K151369",
          "K233236",
          "K093588",
          "K092928",
          "K101220",
          "K080601",
          "K141248",
          "K214081",
          "K240398",
          "K013661",
          "K061893",
          "K211881",
          "K211867",
          "K990071",
          "K071760",
          "K002132",
          "K242822",
          "K143514",
          "K120387",
          "K250064",
          "K082642",
          "K223724",
          "K231825",
          "K222728",
          "K992434",
          "K170969",
          "K001700",
          "K062514",
          "K153368",
          "K982821",
          "K080929",
          "K071873",
          "K151469",
          "K031088",
          "K260207",
          "K053584",
          "K010784",
          "K191384",
          "K992753",
          "K093391",
          "K170355",
          "K030821",
          "K041997",
          "K130617",
          "K151233",
          "K192554",
          "K252784",
          "K132816",
          "K131428",
          "K013535",
          "K171536",
          "K031281",
          "K083672",
          "K110730",
          "K002237",
          "K103246",
          "K040688",
          "K193381",
          "K103146",
          "K082606",
          "K190178",
          "K052325",
          "K223233",
          "K260750",
          "K984196",
          "K212274",
          "K020971",
          "K022961",
          "K032209",
          "K181145",
          "K102915",
          "K981678",
          "K183037",
          "K230557",
          "K992303",
          "K112446",
          "K120551",
          "K201350",
          "K241876",
          "K102011",
          "K143269",
          "K090808",
          "K190387",
          "K002240",
          "K112776",
          "K234068",
          "K250440",
          "K180308",
          "K232479",
          "K083502",
          "K090893",
          "K000922",
          "K242463",
          "K091145",
          "K173635",
          "K101119",
          "K103515",
          "K073020",
          "K180289",
          "K062032",
          "K253091",
          "K193459",
          "K152488"
        ],
        "registration_number": [
          "1038814",
          "2030598",
          "8043933",
          "3019834893",
          "3012039133",
          "3014425747",
          "3016686005",
          "3003873069",
          "3009529630",
          "2183553",
          "3004555507",
          "3011716550",
          "3025309924",
          "3003418325",
          "3000126629",
          "3007791541",
          "9617978",
          "3044735888",
          "1651102",
          "3002808157",
          "3008156050",
          "3003586672",
          "3003793371",
          "3009090417",
          "3004363352",
          "3005136058",
          "3014873236",
          "3025765259",
          "3006579682",
          "3019543601",
          "3006894636",
          "3015777306",
          "3004561814",
          "3010034862",
          "3013410552",
          "3009302839",
          "9611894",
          "3010123525",
          "3003094912",
          "3007037519",
          "3004580128",
          "3022719374",
          "2916710",
          "3022745617",
          "3018004899",
          "3004608878",
          "2939248",
          "3004977335",
          "3030564015",
          "3007774465",
          "3009077524",
          "3016602874",
          "3042177665",
          "3015232217",
          "3023344262",
          "3033527281",
          "2434141",
          "3003768277",
          "3004526608"
        ],
        "fei_number": [
          "1038814",
          "3019834893",
          "3012039133",
          "3014425747",
          "3016686005",
          "3003873069",
          "3002619595",
          "3009529630",
          "2183553",
          "3004555507",
          "3011716550",
          "3025309924",
          "3003418325",
          "3000126629",
          "3007791541",
          "3044735888",
          "3002807741",
          "3002808157",
          "3008156050",
          "3003586672",
          "3003793371",
          "3009090417",
          "3004363352",
          "3005136058",
          "3014873236",
          "3002807880",
          "3025765259",
          "3006579682",
          "3019543601",
          "3006894636",
          "3015777306",
          "3002802883",
          "3004561814",
          "3010034862",
          "3013410552",
          "3009302839",
          "3003094912",
          "3010123525",
          "3007037519",
          "3004580128",
          "3022719374",
          "2916710",
          "3022745617",
          "3018004899",
          "3004608878",
          "2939248",
          "3004977335",
          "3030564015",
          "3007774465",
          "1000518731",
          "3009077524",
          "3016602874",
          "3008581796",
          "3042177665",
          "3015232217",
          "3023344262",
          "3033527281",
          "2434141",
          "3004526608"
        ],
        "device_name": "System, Planning, Radiation Therapy Treatment",
        "medical_specialty_description": "Radiology",
        "regulation_number": "892.5050",
        "device_class": "2"
      }
    }
  ]
}