  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-08-13",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "160084",
      "product_res_number": "Z-0234-2018",
      "event_date_initiated": "2017-09-01",
      "event_date_created": "2017-12-13",
      "recall_status": "Terminated",
      "event_date_terminated": "2019-11-05",
      "res_event_number": "78665",
      "product_code": "MUJ",
      "k_numbers": [
        "K080601"
      ],
      "product_description": "Elekta ERGO++\n\nProduct Usage:\nERGO is often used for stereotactic treatments.",
      "code_info": "Version 1.7.3 and higher",
      "firm_fei_number": "1937649",
      "recalling_firm": "Elekta Inc",
      "address_1": "13723 Riverport Dr Ste 100 13723 Riverport Dr",
      "address_2": "Ste 100",
      "city": "Maryland Heights",
      "state": "MO",
      "postal_code": "63043-4819",
      "additional_info_contact": "314-993-0003",
      "reason_for_recall": "Incorrect DICOM mapping of the exported collimator or couch angles from ERGO, which would lead to incorrect rotation of the collimator or couch when using a MLC device for planning.",
      "root_cause_description": "Nonconforming Material/Component",
      "action": "Elekta sent an Urgent Important Field Safety Notification letter dated September, 2017.  The letter identified affected product, problem and  actions to be taken.  Customers were instructed that a copy of the Important Field Safety Notice is to be kept with the most current labeling and all personnel working with the product should be made aware of the content of the letter.  The customers were asked to complete the verification tests and return the Important Field Safety Notice Acknowledgment form to their local Elekta representative as soon as possible but no later than 30 days from receipt. For questions contact your local Elekta Care Support Center.",
      "product_quantity": "182",
      "distribution_pattern": "Worldwide Distribution - US Nationwide in the states of:  VA, CA, TX, MO, NY, WA, NM, MA, FL, CT, OK, SC, MS, NY, GA, NC and the countries of:  \nAUSTRALIA, BANGLADESH, BRAZIL, BULGARIA, CANADA, COLOMBIA, CZECH REPUBLIC, ECUADOR, FRANCE, GERMANY, GREECE, HONG KONG, INDIA, IRELAND, ITALY, JAPAN, JORDAN, MALAYSIA, MEXICO, NETHERLANDS, NEW ZEALAND, PERU, PHILIPPINES, PORTUGAL, RUSSIA, \nSAUDI ARABIA, SINGAPORE, SOUTH KOREA, SPAIN, TAIWAN, THAILAND, TURKEY, VENEZUELA, and VIETNAM",
      "openfda": {
        "k_number": [
          "K071873",
          "K180308",
          "K001295",
          "K161136",
          "K990475",
          "K031349",
          "K233236",
          "K013112",
          "K041997",
          "K112060",
          "K242992",
          "K993675",
          "K160093",
          "K181145",
          "K121448",
          "K130617",
          "K173940",
          "K172163",
          "K250963",
          "K090531",
          "K012017",
          "K203766",
          "K013535",
          "K062032",
          "K082221",
          "K152393",
          "K220582",
          "K080601",
          "K123152",
          "K002237",
          "K091179",
          "K201350",
          "K170355",
          "K090182",
          "K200487",
          "K123357",
          "K241318",
          "K252784",
          "K011246",
          "K992753",
          "K041719",
          "K021268",
          "K243057",
          "K093391",
          "K082606",
          "K132816",
          "K010784",
          "K201607",
          "K022741",
          "K083672",
          "K002147",
          "K212274",
          "K151369",
          "K032209",
          "K091492",
          "K061097",
          "K102011",
          "K190178",
          "K042269",
          "K041971",
          "K083502",
          "K211034",
          "K100552",
          "K223233",
          "K092928",
          "K062514",
          "K151233",
          "K151469",
          "K210645",
          "K022036",
          "K222728",
          "K223279",
          "K002509",
          "K090893",
          "K982821",
          "K990071",
          "K170086",
          "K211379",
          "K214081",
          "K192554",
          "K142108",
          "K071938",
          "K193109",
          "K112776",
          "K013661",
          "K983343",
          "K232479",
          "K041403",
          "K101076",
          "K100092",
          "K111311",
          "K080888",
          "K071760",
          "K123263",
          "K222312",
          "K230557",
          "K993895",
          "K051497",
          "K101220",
          "K223724",
          "K193640",
          "K252109",
          "K101119",
          "K171885",
          "K020027",
          "K992864",
          "K915691",
          "K080929",
          "K180379",
          "K982791",
          "K141283",
          "K182888",
          "K102216",
          "K020971",
          "K994413",
          "K131891",
          "K143514",
          "K151666",
          "K220141",
          "K182665",
          "K202284",
          "K211841",
          "K250064",
          "K082005",
          "K042861",
          "K132971",
          "K151380",
          "K211881",
          "K103246",
          "K040688",
          "K030821",
          "K240671",
          "K153368",
          "K002312",
          "K234068",
          "K260207",
          "K253091",
          "K211867",
          "K131428",
          "K242822",
          "K002240",
          "K252002",
          "K133655",
          "K993923",
          "K031281",
          "K083264",
          "K191384",
          "K091146",
          "K110730",
          "K143269",
          "K992434",
          "K231825",
          "K220783",
          "K982696",
          "K993766",
          "K252304",
          "K090808",
          "K063230",
          "K141860",
          "K112723",
          "K240398",
          "K050296",
          "K200569",
          "K253050",
          "K000922",
          "K241876",
          "K103146",
          "K133247",
          "K242748",
          "K040474",
          "K120363",
          "K053584",
          "K081112",
          "K193381",
          "K082642",
          "K171536",
          "K093588",
          "K051941",
          "K232799",
          "K250440",
          "K031088",
          "K013644",
          "K151887",
          "K252863",
          "K013673",
          "K032456",
          "K170750",
          "K203469",
          "K061893",
          "K061440",
          "K052325",
          "K100417",
          "K253078",
          "K232400",
          "K032724",
          "K152488",
          "K091145",
          "K151435",
          "K183037",
          "K112446",
          "K192065",
          "K022307",
          "K103093",
          "K083414",
          "K012575",
          "K974770",
          "K103515",
          "K073020",
          "K141248",
          "K981678",
          "K170969",
          "K002132",
          "K151560",
          "K201444",
          "K211511",
          "K063482",
          "K141900",
          "K190387",
          "K140187",
          "K260750",
          "K102915",
          "K180289",
          "K203681",
          "K150547",
          "K242378",
          "K992762",
          "K001700",
          "K991237",
          "K100056",
          "K133331",
          "K984532",
          "K092132",
          "K202789",
          "K173635",
          "K162370",
          "K242463",
          "K992303",
          "K190664",
          "K022411",
          "K984196",
          "K010682",
          "K120551",
          "K090972",
          "K120387",
          "K213438",
          "K032345",
          "K081281",
          "K113102",
          "K200608",
          "K222803",
          "K022961",
          "K991815",
          "K260308",
          "K062967",
          "K042739",
          "K193459",
          "K213787"
        ],
        "registration_number": [
          "3010123525",
          "3004608878",
          "3011716550",
          "3030564015",
          "9617978",
          "3003094912",
          "3010034862",
          "3013410552",
          "3007791541",
          "3009077524",
          "3022745617",
          "3033527281",
          "1038814",
          "3003586672",
          "2183553",
          "3004977335",
          "3002808157",
          "3019834893",
          "3006579682",
          "3016602874",
          "3009302839",
          "3006894636",
          "3004580128",
          "2030598",
          "3014425747",
          "3016686005",
          "3007037519",
          "3004555507",
          "3025765259",
          "3025309924",
          "3003873069",
          "3004526608",
          "3019543601",
          "3003768277",
          "3042177665",
          "1651102",
          "9611894",
          "3018004899",
          "3044735888",
          "3003793371",
          "8043933",
          "3012039133",
          "3008156050",
          "3023344262",
          "3007774465",
          "2434141",
          "3015232217",
          "3015777306",
          "3009090417",
          "3022719374",
          "3000126629",
          "3003418325",
          "3004363352",
          "2939248",
          "3004561814",
          "3009529630",
          "3014873236",
          "3005136058",
          "2916710"
        ],
        "fei_number": [
          "3010123525",
          "3004608878",
          "3011716550",
          "3030564015",
          "3003094912",
          "3010034862",
          "3013410552",
          "3007791541",
          "3009077524",
          "3022745617",
          "3033527281",
          "1038814",
          "3003586672",
          "2183553",
          "3004977335",
          "3002808157",
          "3019834893",
          "3006579682",
          "3016602874",
          "3009302839",
          "3006894636",
          "1000518731",
          "3014425747",
          "3004580128",
          "3016686005",
          "3007037519",
          "3004555507",
          "3025765259",
          "3025309924",
          "3003873069",
          "3004526608",
          "3019543601",
          "3042177665",
          "3002807880",
          "3002807741",
          "3018004899",
          "3044735888",
          "3003793371",
          "3012039133",
          "3008581796",
          "3008156050",
          "3023344262",
          "3002802883",
          "3007774465",
          "2434141",
          "3015232217",
          "3015777306",
          "3009090417",
          "3022719374",
          "3000126629",
          "3002619595",
          "3003418325",
          "3004363352",
          "2939248",
          "3004561814",
          "3009529630",
          "3014873236",
          "3005136058",
          "2916710"
        ],
        "device_name": "System, Planning, Radiation Therapy Treatment",
        "medical_specialty_description": "Radiology",
        "regulation_number": "892.5050",
        "device_class": "2"
      }
    }
  ]
}