  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-08-20",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "151296",
      "product_res_number": "Z-0885-2017",
      "event_date_initiated": "2016-11-18",
      "event_date_created": "2016-12-22",
      "recall_status": "Terminated",
      "event_date_terminated": "2018-06-07",
      "res_event_number": "75798",
      "product_code": "MTF",
      "pma_numbers": [
        "P930027"
      ],
      "product_description": "IMMULITE 2000/IMMULITE 2000 XPi Systems Prostate-Specific Antigen (PSA) Assay, REF/Catalog Number L2KPTS2, SMN 10706281 and REF/Catalog Number L2KPTS6, SMN 10706282 (US); REF/Catalog Number L2KPS2, SMN 10380986 and REF/Catalog Number L2KPS6, SMN 10380996 (OUS); IVD --- Origin: UK Siemens Healthcare Diagnostics Products Ltd. Llanberis, Gwynedd, LL554EL UK\n\nFor in vitro diagnostic use with the IMMULITE /IMMULITE 1000/IMMULITE 2000/2000 XPi Analyzers for the quantitative measurement of prostate-specific antigen (PSA) in human serum, as an aid in the detection of prostate cancer when used in conjunction with digital rectal examination (DRE) in men aged 50 years or older. This assay is further indicated as an adjunctive test to aid in the management of prostate cancer patients.",
      "code_info": "All lots L2KPS2/L2KPS6 - Lots 408, 409, 410 L2KPTS2/L2KPTS6 - Lots D112, D123, D124",
      "firm_fei_number": "2432235",
      "recalling_firm": "Siemens Healthcare Diagnostics, Inc.",
      "address_1": "511 Benedict Ave",
      "city": "Tarrytown",
      "state": "NY",
      "postal_code": "10591-5005",
      "reason_for_recall": "Siemens Healthcare Diagnostics confirmed that the  IMMULITE 2000/ IMMULITE 2000 XPi Systems PSA assays are not meeting the current High-dose Hook Effect expectation in the Instructions for Use.",
      "root_cause_description": "Under Investigation by firm",
      "action": "The firm, Siemens, sent an \"Urgent Medical Device Correction Letter\" (IMC 17-07.A.US, dated 11/2016) was sent via FedEx on 11/18/2016 to the US customers and an \"Urgent Field Safety Notice\" dated 11/2016 to customers outside the US (distribution is determined at the country level).   The letter/notice described the product, problem and actions to be taken. Additionally, Field service personnel were sent an SKB (Service Knowledge Base) describing the issue and instructing them how to deal with customer questions. Customers were instructed to review letter with your medical doctor; review products and follow instructions; complete and return the attached Field Correction Effectiveness Check Form within 30 days by fax to Customer Care Center at (312) 275-7795;  retain this letter with your laboratory records and forward this letter to those who may have received this product.\n\nIf you have any questions, please contact your Siemens Customer Care Center or your local Siemens technical support representative.",
      "product_quantity": "6697 kits (US: 1646 kits; OUS: 5081 kits)",
      "distribution_pattern": "Worldwide Distribution-US (nationwide)and the following countries: Afghanistan, Albania, Algeria, Argentina, Aruba, Austria, Bangladesh, Belarus, Belgium, Bolivia, Bosnia Herzeg, Brazil, British Guyana, Bulgaria, Chile, China, Colombia, Costa Rica, Croatia, Cyprus, Czech Republic, Dominican Rep., Ecuador, Egypt, El Salvador, Estonia, Finland, France, Germany, Greece, Great Britain, Grenada, Guatemala, Honduras, Hungary, Iceland,  India, Indonesia, Iran, Iraq, Israel, Italy, Japan, Jordan, Kazakhstan, Kosovo, Latvia, Lebanon, Lithuania, Macedonia, Malaysia, Mexico,  Netherlands, Nicaragua, Pakistan, Panama, Paraguay, Peru, Philippines,  Poland, Portugal, Romania, Russian Fed., Saudi Arabia, Serbia, Slovakia, Spain, South Africa, South Korea, Suriname, Switzerland, Syria, Taiwan, Tadjikistan, Thailand, Trinidad, Tobago, Tunisia, Turkey, Turkmenistan, United Arab Emirates, Uruguay, Uzbekistan, Venezuela, and Vietnam.",
      "openfda": {
        "pma_number": [
          "P910007",
          "P020027",
          "P040008",
          "P930027",
          "P170037",
          "P950021",
          "P990056",
          "P240021",
          "P000021",
          "P980007",
          "P910065",
          "P850048"
        ],
        "registration_number": [
          "1219913",
          "2432235",
          "9612316",
          "8031673",
          "3005333358",
          "3008344661",
          "2029372",
          "2517506",
          "9610126",
          "3005529799",
          "2122870",
          "3002809144",
          "3002806944"
        ],
        "fei_number": [
          "3002808328",
          "1219913",
          "2432235",
          "2967",
          "3008344661",
          "3002806559",
          "3005333358",
          "1000306617",
          "2517506",
          "3005529799",
          "2122870",
          "3002809144",
          "3002806944"
        ],
        "device_name": "Total, Prostate Specific Antigen (Noncomplexed & Complexed) For Detection Of Prostate Cancer",
        "medical_specialty_description": "Unknown",
        "regulation_number": "",
        "device_class": "3"
      }
    }
  ]
}