      "cfres_id": "150224",
      "product_res_number": "Z-0391-2017",
      "event_date_initiated": "2016-10-25",
      "event_date_posted": "2016-11-10",
      "recall_status": "Terminated",
      "event_date_terminated": "2017-02-06",
      "res_event_number": "75412",
      "product_code": "JEA",
      "product_description": "OR Table, Top U26 H V, Model # 1909793; OR Table Top U26 H V U, Model # 1909794; OR Table Top U24 H V, Model # 1909796; OR Table Top U24 H V U, Model # 1909797; OR Table Top U24 H V W, Model # 1909798; OR Table Top U14 H V, Model # 1909799\n\nProduct Usage:\nPatient positioning during surgery, ranging from anesthesia induction to actual surgery to recover from the anesthesia. Patient transport on the operating table top from a patient transfer system to the operating theater or from the operating theater to a patient transfer system.",
      "code_info": "Model # 190973 - Serial Number Range 102394262 - 102974610; Model # 1909794 - 102884276; Model # 1909796 - 102440024 - 102981676; Model # 1909797 - 102757564 - 102958935; Model # 1909798 - 102831498 - 102831519; Model # 1909799 - 102393683 - 102969656",
      "firm_fei_number": "3003184737",
      "recalling_firm": "Trumpf Medical Systems, Inc.",
      "address_1": "1046 Legrand Blvd",
      "city": "Charleston",
      "state": "SC",
      "postal_code": "29492-7672",
      "additional_info_contact": "Chandler Sprinkles\n843-329-0543",
      "reason_for_recall": "Trumpf has identified six incidents of pinched cables.",
      "root_cause_description": "Process control",
      "action": "Trumpf Medical sent an Urgent Medical Device Correction letter dated October 7, 2016 to affected customers.  The letter identified the affected product, problem and actions to be taken   The letter indicated that a authorized service provider will inspect the table tops and make necessary corrections.  A confirmation notice was included with the letter which is to be returned.  For contact Trupmpf Medical Systems, Inc. at 888-474-9359.",
      "product_quantity": "4 (US) & 229 (Foreign)",
      "distribution_pattern": "Worldwide Distribution - US Nationwide in the states of AZ and SC and the countries of  Australia, Austria, Belgium, China, Czech Republic, Denmark, Finland, France, Germany, Great Britain, Iceland, Italy, Norway, Qatar, Slovenia, Spain, Sweden, Switzerland",
      "openfda": {
        "device_name": "Table, Surgical With Orthopedic Accessories, Ac-Powered",
        "medical_specialty_description": "General, Plastic Surgery",
        "regulation_number": "878.4960",
        "device_class": "1",
        "registration_number": [
          "3007031002",
          "2916273",
          "2221819",
          "8043933",
          "3013522950",
          "9680168",
          "3027847726",
          "1066635",
          "3013836619",
          "8010652",
          "3012995405",
          "3003923584",
          "3043007473",
          "3031563141",
          "2921578",
          "1043572",
          "3015223105",
          "1000351276",
          "3010890274",
          "3009760038",
          "3012329926",
          "9681642",
          "3011111237",
          "3007143268"
        ],
        "fei_number": [
          "3007031002",
          "1000395711",
          "2916273",
          "2221819",
          "3013522950",
          "1000295034",
          "3002619595",
          "1841",
          "3027847726",
          "3013836619",
          "3003184737",
          "3012995405",
          "3003923584",
          "3043007473",
          "3031563141",
          "2921578",
          "1043572",
          "3015223105",
          "1000351276",
          "3010890274",
          "3009760038",
          "3012329926",
          "3011111237",
          "3007143268"
        ],
        "k_number": [
          "K900290",
          "K881060",
          "K911522",
          "K924094",
          "K873080",
          "K873079",
          "K910736",
          "K894789",
          "K874762",
          "K953071"
        ]
      }
    }
  ]
}