      "cfres_id": "147873",
      "product_res_number": "Z-0138-2017",
      "event_date_initiated": "2016-06-23",
      "event_date_posted": "2016-10-19",
      "recall_status": "Terminated",
      "event_date_terminated": "2017-01-26",
      "res_event_number": "74542",
      "product_code": "FEB",
      "k_numbers": [
        "K103264"
      ],
      "product_description": "OER-Pro Endoscope Reprocessor, Endoscope washer/disinfector",
      "code_info": "Model: OER-Pro, All serial numbers affected",
      "firm_fei_number": "2429304",
      "recalling_firm": "Olympus Corporation of the Americas",
      "address_1": "3500 Corporate Pkwy",
      "address_2": "PO Box 610",
      "city": "Center Valley",
      "state": "PA",
      "postal_code": "18034-0610",
      "additional_info_contact": "Laura Storms\n484-896-5688",
      "reason_for_recall": "New warning requiring Users to conduct duodenoscope precleaning and manual cleaning even when using an Automated Endoscope Reprocessor (AER) that has instructions that may indicate a user could forego certain steps in precleaning and manual cleaning of the endoscopes.",
      "root_cause_description": "Under Investigation by firm",
      "action": "Olympus America Inc. (OAI) mailed a letter to customers informing them that they are issuing an updated Operation Manual for the OER-Pro Automated Endoscope Reprocessor.\nThe following actions were asked to be taken:\n-Olympus has discontinued previously distributed copies of the OER-Pro Operation Manual. \n-  Inspect your inventory of Operation Manuals and discard any existing inventory of OER-Pro Operation Manuals.     \n- Implement use of the enclosed OER-Pro Operation Manual, which contains the new Warning on pages 73 and 80.\n- Ensure all reprocessing personnel are completely knowledgeable and thoroughly trained on the requirement to perform precleaning and manual cleaning of Olympus duodenoscopes prior to placing the duodenoscopes in the OER-Pro for high level disinfection.  \n- Additional copies of the new OER-Pro Operation Manual can be obtained by contacting our Technical Assistance Center at 1-800-848-9024, option 1, or by indicating on the enclosed questionnaire. Additional Operation Manuals will be mailed to your facility - Please indicate on the enclosed questionnaire that you have received this notification. Fax the completed form to (484) 896-7128.",
      "product_quantity": "2, 686 units",
      "distribution_pattern": "Distributed to: AK,AL,AR,AZ,CA,CO,CT,DC,DE,FL,GA,HI,IA,ID,IL,IN,KS,KY,LA,MA,MD,ME,MI,MN,MO,MS,MT,NC,ND,NE,NH,NJ,NM,NV,NY,OH,OK,OR,PA,RI,SC,TN,TX,UT,VA,VT,WA,WI,WV,WY",
      "openfda": {
        "k_number": [
          "K820152",
          "K172677",
          "K181865",
          "K914145",
          "K213833",
          "K241168",
          "K961607",
          "K840208",
          "K140977",
          "K901439",
          "K973558",
          "K924103",
          "K061430",
          "K933354",
          "K063876",
          "K162120",
          "K830026",
          "K201920",
          "K923687",
          "K061899",
          "K040883",
          "K850268",
          "K915402",
          "K944776",
          "K921179",
          "K923672",
          "K924135",
          "K012309",
          "K060458",
          "K924655",
          "K162128",
          "K101158",
          "K915620",
          "K092387",
          "K914442",
          "K082392",
          "K810818",
          "K122172",
          "K152189",
          "K093106",
          "K941134",
          "K082988",
          "K120357",
          "K103264",
          "K932930",
          "K941648",
          "K181472",
          "K190969",
          "K000216",
          "K964871",
          "K954745",
          "K230930",
          "K173590",
          "K914524",
          "K944249",
          "K102996",
          "K243433"
        ],
        "device_name": "Accessories, Cleaning, For Endoscope",
        "medical_specialty_description": "Gastroenterology, Urology",
        "regulation_number": "876.1500",
        "device_class": "2",
        "registration_number": [
          "2150060",
          "1651395",
          "3018094310",
          "9610849",
          "3042172882",
          "3005987240",
          "3000251274",
          "9680353",
          "8010047",
          "1222168",
          "3024021261",
          "3005646850",
          "3003950207",
          "3015392401",
          "2084725",
          "1220592",
          "3008157119",
          "1418479",
          "2647580",
          "3011050570",
          "2518897",
          "1527821",
          "1219930",
          "9610595",
          "3007082252"
        ],
        "fei_number": [
          "2150060",
          "2523209",
          "3003662624",
          "3018094310",
          "3002807795",
          "3042172882",
          "1000080301",
          "3005987240",
          "3000251274",
          "1222168",
          "3024021261",
          "3002807391",
          "3003012447",
          "3005646850",
          "3003950207",
          "3004097451",
          "3015392401",
          "1220592",
          "3008157119",
          "1418479",
          "2647580",
          "3011050570",
          "1527821",
          "1219930",
          "3002964398"
        ]
      }
    }
  ]
}