  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-08-15",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "cfres_id": "140080",
      "product_res_number": "Z-0121-2016",
      "event_date_initiated": "2015-08-21",
      "event_date_posted": "2015-10-15",
      "recall_status": "Terminated",
      "event_date_terminated": "2016-10-24",
      "res_event_number": "72168",
      "product_code": "IMJ",
      "k_numbers": [
        "K083433"
      ],
      "product_description": "Monode, Shortwave Accessory\nModel #: 02200002\n\nUsed in conjunction with the Intelect Shortwave Diathermy 100 and Intelect Shortwave Diathermy 400 units.  For the clinical application of electromagnetic energy in the radio frequency of 27.12 megahertz to generate deep heat within body tissues.",
      "code_info": "Model #: 02200002  All units received from the manufacture prior to the week of July 12, 2015",
      "firm_fei_number": "2020737",
      "recalling_firm": "DJO, LLC",
      "address_1": "1430 Decision St",
      "city": "Vista",
      "state": "CA",
      "postal_code": "92081-8553",
      "additional_info_contact": "760-727-1280",
      "reason_for_recall": "Overheating and burning of the wire insulation inside the applicator.",
      "root_cause_description": "Device Design",
      "action": "The firm sent out two customer notification letters; one to distributors and one to direct users.  Letters were sent September 1, 2015 via USPS certified return receipt.\n\nDistributors were asked to obtain a list of their customers with contact information that have purchase or received the monode accessory or Intelect Shortwave device that included the monode as an accessory item.  Once the list has been assembled the firm requests that it be forwarded to DJO Global Chattanooga Product Support by phone 877-733-4888, or by e-mail at monode.support@djoglobal.com.  The firm's notification states that customers will be sent an upgraded monode accessory along with a pre-paid shipper for the return of the current used unit.\n\nAny questions the letter states to contact Product Support per the contact information above or William Fisher, Global Regulatory Compliance at 760-734-3126.\n\nLetters sent to direct users received the same instruction of returning the product for a replacement.  Any questions the letter states to call 877-733-4888 or email at monode.support@djoglobal.com.",
      "product_quantity": "2887",
      "distribution_pattern": "Worldwide Distribution - US Nationwide in the states of WY, OH, WA, NC, FL, NE, GA, KS CA, MO, IN, MA, IL, OK, AZ, TX, AR, UT, NJ, WI, PA, SC, WV, NY, MI, MN, VA, AK, TN, OR, NC, NH, KY, CO, NV, ID and the countries of El Salvador, China, Ecuador, South Korea, Chile, Israel, Peru, Nicaragua, Bolivia, Indonesia",
      "openfda": {
        "k_number": [
          "K131899",
          "K173300",
          "K022846",
          "K842801",
          "K850573",
          "K083433",
          "K781320",
          "K861247",
          "K250376",
          "K862376",
          "K861864",
          "K030382",
          "K153456",
          "K182363",
          "K862589",
          "K781455",
          "K252963",
          "K042554",
          "K864653",
          "K162240",
          "K841874",
          "K022458",
          "K934151",
          "K962703",
          "K161862",
          "K973732",
          "K223620",
          "K844416",
          "K862469",
          "K862932",
          "K871633",
          "K852166",
          "K862468",
          "K020227",
          "K781316",
          "K780755",
          "K864766",
          "K243112",
          "K121123",
          "K771540",
          "K962243",
          "K861248",
          "K120093",
          "K131926",
          "K964083"
        ],
        "device_name": "Diathermy, Shortwave, For Use In Applying Therapeutic Deep Heat",
        "medical_specialty_description": "Physical Medicine",
        "regulation_number": "890.5290",
        "device_class": "2",
        "registration_number": [
          "1412854",
          "1911273",
          "3004154499",
          "2013558",
          "2011115",
          "3017264244",
          "8010720",
          "3012316249",
          "3014122529",
          "3007134923",
          "9616086",
          "3005170249",
          "9612147",
          "2032108",
          "3013682776"
        ],
        "fei_number": [
          "1412854",
          "1000119345",
          "3004154499",
          "2013558",
          "2011115",
          "3017264244",
          "3005170249",
          "3012316249",
          "3014122529",
          "7759",
          "3007134923",
          "3003070149",
          "3006076154",
          "3013682776",
          "3002806913"
        ]
      }
    }
  ]
}