  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-18",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "manufacturer_contact_zip_ext": "",
      "manufacturer_g1_address_2": "",
      "event_location": "",
      "report_to_fda": "",
      "manufacturer_contact_t_name": "",
      "manufacturer_contact_state": "",
      "manufacturer_link_flag": "N",
      "manufacturer_contact_address_2": "",
      "manufacturer_g1_city": "",
      "manufacturer_contact_address_1": "",
      "manufacturer_contact_pcity": "",
      "event_type": "Other",
      "report_number": "MW6002072",
      "type_of_report": [
        "Initial submission"
      ],
      "product_problem_flag": "",
      "date_received": "20260910",
      "manufacturer_address_2": "",
      "pma_pmn_number": "",
      "date_of_event": "20260831",
      "reprocessed_and_reused_flag": "",
      "manufacturer_address_1": "",
      "exemption_number": "",
      "manufacturer_contact_zip_code": "",
      "reporter_occupation_code": "PATIENT",
      "manufacturer_contact_plocal": "",
      "noe_summarized": "1",
      "manufacturer_contact_l_name": "",
      "source_type": [
        ""
      ],
      "distributor_zip_code_ext": "",
      "manufacturer_g1_postal_code": "",
      "manufacturer_g1_state": "",
      "reporter_country_code": "US",
      "manufacturer_contact_area_code": "",
      "date_added": "20260911",
      "manufacturer_contact_f_name": "",
      "previous_use_code": "",
      "device": [
        {
          "device_event_key": "",
          "implant_flag": "",
          "date_removed_flag": "",
          "device_sequence_number": "2367295",
          "implant_date_year": "",
          "date_removed_year": "",
          "serviced_by_3rd_party_flag": "",
          "date_received": "20260910",
          "brand_name": "Manafuse",
          "generic_name": "Stimulator, Bone Growth, Non-Invasive",
          "manufacturer_d_name": "",
          "manufacturer_d_address_1": "",
          "manufacturer_d_address_2": "",
          "manufacturer_d_city": "",
          "manufacturer_d_state": "",
          "manufacturer_d_zip_code": "",
          "manufacturer_d_zip_code_ext": "",
          "manufacturer_d_country": "",
          "manufacturer_d_postal_code": "",
          "device_operator": "",
          "model_number": "",
          "catalog_number": "",
          "lot_number": "DJ-250807-01",
          "other_id_number": "",
          "device_availability": "",
          "device_report_product_code": "LOF",
          "device_age_text": "",
          "device_evaluated_by_manufacturer": "",
          "combination_product_flag": "N",
          "udi_di": "",
          "udi_public": "",
          "openfda": {
            "device_name": "Stimulator, Bone Growth, Non-Invasive",
            "medical_specialty_description": "Orthopedic",
            "regulation_number": "890.5870",
            "device_class": "2"
          }
        }
      ],
      "product_problems": [
        "Date/Time-Related Software Problem",
        "Application Program Problem: Medication Error"
      ],
      "reporter_state_code": "",
      "manufacturer_zip_code": "",
      "suppl_dates_mfr_received": "",
      "mfr_report_type": "",
      "manufacturer_contact_country": "",
      "date_changed": "20261019",
      "health_professional": "N",
      "summary_report_flag": "N",
      "manufacturer_g1_zip_code_ext": "",
      "manufacturer_contact_extension": "",
      "manufacturer_city": "",
      "manufacturer_contact_phone_number": "",
      "patient": [
        {
          "patient_sequence_number": "1",
          "date_received": "20260910",
          "sequence_number_treatment": [
            ""
          ],
          "sequence_number_outcome": [
            ""
          ],
          "patient_age": "46 YR",
          "patient_sex": "Unknown",
          "patient_weight": "",
          "patient_ethnicity": "",
          "patient_race": "",
          "patient_problems": [
            "No Clinical Signs, Symptoms or Conditions"
          ]
        }
      ],
      "distributor_city": "",
      "date_report": "20260902",
      "initial_report_to_fda": "",
      "distributor_state": "",
      "event_key": "",
      "manufacturer_g1_country": "",
      "manufacturer_contact_city": "",
      "mdr_report_key": "50713570",
      "removal_correction_number": "",
      "number_devices_in_event": "",
      "manufacturer_name": "",
      "report_source_code": "Voluntary report",
      "remedial_action": [
        ""
      ],
      "manufacturer_g1_zip_code": "",
      "report_to_manufacturer": "",
      "manufacturer_zip_code_ext": "",
      "manufacturer_g1_name": "",
      "adverse_event_flag": "",
      "distributor_address_1": "",
      "manufacturer_state": "",
      "distributor_address_2": "",
      "manufacturer_postal_code": "",
      "single_use_flag": "",
      "manufacturer_country": "",
      "mdr_text": [
        {
          "mdr_text_key": "16251156682",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "0",
          "text": "Biotronik submits this report to comply with FDA regulations 21 CFR parts 4 and 803. Biotronik has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report. This report does not constitute an admission or a conclusion by Biotronik, or its employees that the device, Biotronik, or its employee caused or contributed to the event described in the report. Any required fields that are unpopulated are blank because the information is currently unknown or unavailable. Biotronik will submit a supplemental report if additional relevant information becomes known."
        },
        {
          "mdr_text_key": "15751156681",
          "text_type_code": "Description of Event or Problem",
          "patient_sequence_number": "0",
          "text": "Device: Manafuse (DJO, LLC / Enovis), REF MFUSE01, SN (b)(6), LOTDJ-250807-01. Acquisition: Prescribed by Dr. (b)(6), for a fracture of the third metatarsal of my right foot. The device was shipped directly to my home by the manufacturer in (b)(6) 2026. It is an Rx only device, used at home by me, the patient, per the instructions for use. A company representative assisted with initial setup. I am the only person involved or affected. Problem: The device's internal treatment timer does not run for the duration it displays. Eachtreatment session is specified as 20 minutes, and the device shows a 20 minutecountdown after I press start. The countdown runs slower than real time, so a sessionthe device reports as 20 minutes actually takes longer than 20 minutes of clock time.How I observed it: On first use I started an independent 20 minute timer at the moment Ipressed start on the device. When the independent timer expired, the device stillshowed time remaining. I have repeated this comparison against three independenttime sources: an Amazon Alexa timer, an Apple iPhone timer, and the official U.S. timereference published by NIST (time.gov). All three agree with each other and disagreewith the device. Over each 20 minute session the device runs approximately 18seconds long. The discrepancy is consistent, reproducible, and in the same directionevery time. Timing of events: The problem was present on the very first use, on (b)(6) 2026, and has occurred on every session since. I have completed approximately sixsessions to date. The prescribed regimen is a minimum of two sessions per day, withup to five permitted. The defect is not intermittent and did not develop over time.Because this is a timekeeping fault rather than a physiological effect, there is nothingthat resolves when I stop using the device. Medical diagnosis and treatment: I am beingtreated for a fracture of the third metatarsal of my right foot. The device was prescribedas an adjunct to promote bone healing. I have not experienced any injury, adversesymptom, or clinical complication that I attribute to this problem. I am reporting adevice malfunction, not a patient harm event. Why I consider this significant: Thetherapeutic dose delivered by this device is a function of acoustic output and exposuretime. The output parameters printed on the device are tightly specified (temporalaverage power 117 mW +/- 30%, SATA 30 mW/cm² +/- 30%, frequency 1.5 MHz +/- 5%,ERA 3.88 cm² +/- 20%, collimated beam, pulsed waveform), which indicates dosecontrol matters for this product. If the timer is inaccurate, the actual exposure time persession, and therefore the cumulative dose over a course of treatment, differs fromwhat the device reports and from what was prescribed and studied. Any adherence orusage data logged by the device is also recorded against an incorrect time base, whichwould affect the reliability of compliance data used clinically or in post-market analysis.Timekeeping is among the simplest functions in a device like this. A defect here raisesa question about firmware verification and validation more broadly. I am asking FDA todetermine whether this is a unit-specific fault or a lot or design level issue, and whether the manufacturer is aware of it. I have not contacted DJO/Enovis formally. I planto notify the company representative who assisted with my setup today. / Productdetails: Manufacturer: DJO, LLC (Enovis), Carlsbad, CA 92010. Ph: 800-263-6004Brand/Model: Manafuse REF: MFUSE01 GTIN: (b)(6) SN: (b)(6)UDI: (b)(4). Label: TD-MFUSE01-LBL2 Rev C Rx only."
        }
      ],
      "number_patients_in_event": "",
      "distributor_name": "",
      "manufacturer_g1_address_1": "",
      "distributor_zip_code": "",
      "manufacturer_contact_postal_code": "",
      "manufacturer_contact_exchange": "",
      "manufacturer_contact_pcountry": "",
      "suppl_dates_fda_received": ""
    }
  ]
}