  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-08",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "manufacturer_contact_zip_ext": "",
      "manufacturer_g1_address_2": "",
      "event_location": "NO INFORMATION",
      "report_to_fda": "I",
      "manufacturer_contact_t_name": "",
      "manufacturer_contact_state": "",
      "manufacturer_link_flag": "N",
      "manufacturer_contact_address_2": "",
      "manufacturer_g1_city": "",
      "manufacturer_contact_address_1": "",
      "manufacturer_contact_pcity": "",
      "event_type": "Injury",
      "report_number": "MW5070965",
      "type_of_report": [
        "Initial submission"
      ],
      "product_problem_flag": "Y",
      "date_received": "20170711",
      "manufacturer_address_2": "",
      "pma_pmn_number": "",
      "date_of_event": "20170706",
      "reprocessed_and_reused_flag": "N",
      "manufacturer_address_1": "",
      "exemption_number": "",
      "manufacturer_contact_zip_code": "",
      "reporter_occupation_code": "NURSE",
      "manufacturer_contact_plocal": "",
      "noe_summarized": "1",
      "manufacturer_contact_l_name": "",
      "source_type": [
        ""
      ],
      "distributor_zip_code_ext": "",
      "manufacturer_g1_postal_code": "",
      "manufacturer_g1_state": "",
      "reporter_country_code": "US",
      "manufacturer_contact_area_code": "",
      "date_added": "20170713",
      "manufacturer_contact_f_name": "",
      "previous_use_code": "",
      "device": [
        {
          "device_event_key": "",
          "implant_flag": "",
          "date_removed_flag": "",
          "device_sequence_number": "485290",
          "implant_date_year": "",
          "date_removed_year": "",
          "serviced_by_3rd_party_flag": "",
          "date_received": "20170711",
          "brand_name": "DA VINCI STAPLER 45",
          "generic_name": "STAPLER",
          "manufacturer_d_name": "INTUITIVE SURGICAL",
          "manufacturer_d_address_1": "",
          "manufacturer_d_address_2": "",
          "manufacturer_d_city": "",
          "manufacturer_d_state": "",
          "manufacturer_d_zip_code": "",
          "manufacturer_d_zip_code_ext": "",
          "manufacturer_d_country": "",
          "manufacturer_d_postal_code": "",
          "device_operator": "HEALTH PROFESSIONAL",
          "model_number": "DA VINCI XI",
          "catalog_number": "470298",
          "lot_number": "S10161130 0005",
          "other_id_number": "",
          "device_availability": "Yes",
          "device_report_product_code": "GAG",
          "device_age_text": "",
          "device_evaluated_by_manufacturer": "",
          "combination_product_flag": "Y",
          "udi_di": "",
          "udi_public": "",
          "openfda": {
            "device_name": "Stapler, Surgical",
            "medical_specialty_description": "General Hospital",
            "regulation_number": "878.4740",
            "device_class": "2"
          }
        },
        {
          "device_event_key": "",
          "implant_flag": "",
          "date_removed_flag": "",
          "device_sequence_number": "485291",
          "implant_date_year": "",
          "date_removed_year": "",
          "serviced_by_3rd_party_flag": "",
          "date_received": "20170711",
          "brand_name": "ENDOWRIST STAPLER SHEATH",
          "generic_name": "ENDOWRIST STAPLER SHEATH",
          "manufacturer_d_name": "INTUITIVE SURGICAL",
          "manufacturer_d_address_1": "",
          "manufacturer_d_address_2": "",
          "manufacturer_d_city": "",
          "manufacturer_d_state": "",
          "manufacturer_d_zip_code": "",
          "manufacturer_d_zip_code_ext": "",
          "manufacturer_d_country": "",
          "manufacturer_d_postal_code": "",
          "device_operator": "HEALTH PROFESSIONAL",
          "model_number": "",
          "catalog_number": "410370",
          "lot_number": "M10170327",
          "other_id_number": "",
          "device_availability": "Yes",
          "device_report_product_code": "GAG",
          "device_age_text": "",
          "device_evaluated_by_manufacturer": "",
          "combination_product_flag": "Y",
          "udi_di": "",
          "udi_public": "",
          "openfda": {
            "device_name": "Stapler, Surgical",
            "medical_specialty_description": "General Hospital",
            "regulation_number": "878.4740",
            "device_class": "2"
          }
        }
      ],
      "product_problems": [
        "Detachment Of Device Component",
        "Contamination",
        "Fitting Problem"
      ],
      "reporter_state_code": "VA",
      "manufacturer_zip_code": "",
      "suppl_dates_mfr_received": "",
      "mfr_report_type": "",
      "manufacturer_contact_country": "",
      "date_changed": "20250815",
      "health_professional": "",
      "summary_report_flag": "N",
      "manufacturer_g1_zip_code_ext": "",
      "manufacturer_contact_extension": "",
      "manufacturer_city": "",
      "manufacturer_contact_phone_number": "",
      "patient": [
        {
          "patient_sequence_number": "1",
          "date_received": "20170711",
          "sequence_number_treatment": [
            ""
          ],
          "sequence_number_outcome": [
            "Required Intervention"
          ],
          "patient_age": "",
          "patient_sex": "",
          "patient_weight": "",
          "patient_ethnicity": "",
          "patient_race": "",
          "patient_problems": [
            "No Information",
            "No Information"
          ]
        }
      ],
      "distributor_city": "",
      "date_report": "20170711",
      "initial_report_to_fda": "",
      "distributor_state": "",
      "event_key": "",
      "manufacturer_g1_country": "",
      "manufacturer_contact_city": "",
      "mdr_report_key": "6710596",
      "removal_correction_number": "",
      "number_devices_in_event": "",
      "manufacturer_name": "",
      "report_source_code": "Voluntary report",
      "remedial_action": [
        ""
      ],
      "manufacturer_g1_zip_code": "",
      "report_to_manufacturer": "",
      "manufacturer_zip_code_ext": "",
      "manufacturer_g1_name": "",
      "adverse_event_flag": "N",
      "distributor_address_1": "",
      "manufacturer_state": "",
      "distributor_address_2": "",
      "manufacturer_postal_code": "",
      "single_use_flag": "",
      "manufacturer_country": "",
      "mdr_text": [
        {
          "mdr_text_key": "80067433",
          "text_type_code": "Description of Event or Problem",
          "patient_sequence_number": "1",
          "text": "THE ENDOWRIST STAPLER SHEATH (REF: (B)(4)) USED IN THE DA VINCI XI STAPLER 45 (REF: (B)(4)) TO COVER THE END SHAFT OF THE STAPLER HANDPIECE LOOKS LIKE AN ORIGINAL OEM PART THAT HAS ALWAYS BEEN A PART OF THE STAPLER. THERE WAS NO CLEAR WARNING OR BRIGHT NOTICE TO INSTRUCT USERS TO REMOVE THE SHEATH PRIOR TO SENDING TO STERILE PROCESSING DEPARTMENT (SPD) FOR REPROCESSING. THE BLACK PIECE OF THE SHEATH HAPPENED TO DISENGAGE FROM THE OTHER PART OF THE SHEATH AND WAS LEFT ON THE INSTRUMENT DURING THIS EVENT. THE SPD TEAM DID NOT NOTICE AND THE HANDPIECE WAS STERILIZED WITH THE PART OF THE SHEATH INTACT. THE INSTRUMENT WAS THEN USED ON A CASE. IT WAS DISCOVERED THE REMAINING PIECE WAS NOT PART OF THE STAPLER HANDPIECE WHEN ANOTHER SHEATH WAS INSERTED AND THAT THE STAPLER WOULD NOT FIT THE CANNULA. AT THIS POINT, THE INSTRUMENT BECOMES CONTAMINATED WITH BIOBURDEN (PART OF THE REMAINING SHEATH) AND THE WOUND CLASSIFICATION CHANGES FROM CLEAN TO CONTAMINATED. REQUEST THAT CHANGES TO THE SHEATH BE MADE TO WARN USERS THE SHEATH MUST BE REMOVED AFTER A CASE TO INCLUDE A RED WARNING \"DISPOSE AFTER USE\" OR CHANGING ENTIRE COLOR TO MAKE IT STAND OUT."
        }
      ],
      "number_patients_in_event": "",
      "distributor_name": "",
      "manufacturer_g1_address_1": "",
      "distributor_zip_code": "",
      "manufacturer_contact_postal_code": "",
      "manufacturer_contact_exchange": "",
      "manufacturer_contact_pcountry": "",
      "suppl_dates_fda_received": ""
    }
  ]
}