  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-08",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "manufacturer_contact_zip_ext": "",
      "manufacturer_g1_address_2": "",
      "event_location": "",
      "report_to_fda": "",
      "manufacturer_contact_t_name": "MS.",
      "manufacturer_contact_state": "CA",
      "manufacturer_link_flag": "Y",
      "manufacturer_contact_address_2": "",
      "manufacturer_g1_city": "REDWOOD CITY",
      "manufacturer_contact_address_1": "150 SHORELINE DRIVE",
      "manufacturer_contact_pcity": "62825447",
      "event_type": "Injury",
      "report_number": "3014447948-2024-00008",
      "type_of_report": [
        "Initial submission",
        "Followup"
      ],
      "product_problem_flag": "N",
      "date_received": "20240416",
      "manufacturer_address_2": "",
      "pma_pmn_number": "K211493",
      "date_of_event": "20240325",
      "reprocessed_and_reused_flag": "N",
      "manufacturer_address_1": "",
      "exemption_number": "",
      "manufacturer_contact_zip_code": "94065",
      "reporter_occupation_code": "PHYSICIAN",
      "manufacturer_contact_plocal": "6282544750",
      "noe_summarized": "1",
      "manufacturer_contact_l_name": "KAUR",
      "source_type": [
        "Health Professional",
        "Company representation"
      ],
      "distributor_zip_code_ext": "",
      "manufacturer_g1_postal_code": "94065",
      "manufacturer_g1_state": "CA",
      "reporter_country_code": "US",
      "manufacturer_contact_area_code": "628",
      "date_added": "20240416",
      "manufacturer_contact_f_name": "HARMINDER",
      "device_date_of_manufacturer": "20210504",
      "previous_use_code": "R",
      "device": [
        {
          "device_event_key": "",
          "implant_flag": "",
          "date_removed_flag": "",
          "device_sequence_number": "1063338",
          "implant_date_year": "",
          "date_removed_year": "",
          "serviced_by_3rd_party_flag": "U",
          "date_received": "20240416",
          "brand_name": "MONARCH BRONCHOSCOPE",
          "generic_name": "BRONCHOSCOPE (FLEXIBLE OR RIGID) AND ACCESSORIES",
          "manufacturer_d_name": "AURIS HEALTH, INC.",
          "manufacturer_d_address_1": "150 SHORELINE DR.",
          "manufacturer_d_address_2": "",
          "manufacturer_d_city": "REDWOOD CITY",
          "manufacturer_d_state": "CA",
          "manufacturer_d_zip_code": "94065",
          "manufacturer_d_zip_code_ext": "",
          "manufacturer_d_country": "US",
          "manufacturer_d_postal_code": "94065",
          "device_operator": "HEALTH PROFESSIONAL",
          "model_number": "MON-000006",
          "catalog_number": "",
          "lot_number": "",
          "other_id_number": "",
          "device_availability": "No",
          "device_report_product_code": "EOQ",
          "device_age_text": "DA",
          "device_evaluated_by_manufacturer": "R",
          "combination_product_flag": "N",
          "udi_di": "B634MON0000060",
          "udi_public": "+B634MON0000060/16D20210504",
          "openfda": {
            "device_name": "Bronchoscope (Flexible Or Rigid)",
            "medical_specialty_description": "Ear, Nose, Throat",
            "regulation_number": "874.4680",
            "device_class": "2"
          }
        }
      ],
      "product_problems": [
        "Adverse Event Without Identified Device or Use Problem",
        "Adverse Event Without Identified Device or Use Problem"
      ],
      "reporter_state_code": "AZ",
      "manufacturer_zip_code": "",
      "suppl_dates_mfr_received": "05/23/2024",
      "mfr_report_type": "Thirty-Day",
      "manufacturer_contact_country": "US",
      "date_changed": "20250819",
      "health_professional": "Y",
      "summary_report_flag": "N",
      "manufacturer_g1_zip_code_ext": "",
      "manufacturer_contact_extension": "",
      "manufacturer_city": "",
      "manufacturer_contact_phone_number": "6282",
      "patient": [
        {
          "patient_sequence_number": "1",
          "date_received": "20240416",
          "sequence_number_treatment": [
            ""
          ],
          "sequence_number_outcome": [
            "Required Intervention",
            " H"
          ],
          "patient_age": "NA",
          "patient_sex": "Unknown",
          "patient_weight": "",
          "patient_ethnicity": "",
          "patient_race": "",
          "patient_problems": [
            "Pneumothorax",
            "Pneumothorax"
          ]
        }
      ],
      "distributor_city": "",
      "date_report": "20240524",
      "initial_report_to_fda": "",
      "distributor_state": "",
      "event_key": "",
      "manufacturer_g1_country": "US",
      "manufacturer_contact_city": "REDWOOD CITY",
      "mdr_report_key": "19122005",
      "removal_correction_number": "",
      "number_devices_in_event": "",
      "date_manufacturer_received": "20240327",
      "manufacturer_name": "",
      "report_source_code": "Manufacturer report",
      "remedial_action": [
        ""
      ],
      "manufacturer_g1_zip_code": "94065",
      "report_to_manufacturer": "",
      "manufacturer_zip_code_ext": "",
      "manufacturer_g1_name": "AURIS HEALTH, INC.",
      "adverse_event_flag": "Y",
      "distributor_address_1": "",
      "manufacturer_state": "",
      "distributor_address_2": "",
      "manufacturer_postal_code": "",
      "single_use_flag": "",
      "manufacturer_country": "",
      "mdr_text": [
        {
          "mdr_text_key": "343315368",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "0",
          "text": "THE ROOT CAUSE OF THE REPORTED ISSUE WAS DUE TO EM LAYING IN BETWEEN BRANCH LIKELY DUE TO CT-BODY DIVERGENCE. A REVIEW OF THE DEVICE HISTORY RECORD (DHR) WAS PERFORMED. THERE ARE NO REPORTS OF NONCONFORMANCE THAT RELATE TO THE REPORTED INCIDENT. A REVIEW FOR SIMILAR COMPLAINT SHOWS THE REPORTED ISSUE IS A KNOWN ISSUE HOWEVER THE ROOT CAUSE IS SPECIFIC TO EACH INDIVIDUAL CASE."
        },
        {
          "mdr_text_key": "340339086",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "0",
          "text": "THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY AURIS HEALTH, INC., OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, AURIS HEALTH, INC., OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE."
        },
        {
          "mdr_text_key": "340339087",
          "text_type_code": "Description of Event or Problem",
          "patient_sequence_number": "0",
          "text": "IT WAS REPORTED THAT WHILE DRIVING IN THE RIGHT UPPER LOB (RUL), AND 25MM OUT FROM THE TARGET, USER DECIDED TO DO A SPIN TO CONFIRM HE WAS IN LINE WITH THE LESION AND GET READY TO PLACE A DYED COIL. THE SPIN WAS DONE AND THE SCOPE WAS OBSERVED TO BE THROUGH THE LUNG AND INTO THE PLEURAE WHILE THE SYSTEM WAS SHOWING THEY WERE 25MM OUT, RESULTING IN A PNEUMOTHORAX."
        }
      ],
      "number_patients_in_event": "",
      "distributor_name": "",
      "manufacturer_g1_address_1": "150 SHORELINE DRIVE",
      "distributor_zip_code": "",
      "manufacturer_contact_postal_code": "94065",
      "manufacturer_contact_exchange": "628",
      "manufacturer_contact_pcountry": "",
      "suppl_dates_fda_received": "05/24/2024"
    }
  ]
}