  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-08",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "manufacturer_contact_zip_ext": "",
      "manufacturer_g1_address_2": "",
      "event_location": "",
      "report_to_fda": "",
      "manufacturer_contact_t_name": "MRS.",
      "manufacturer_contact_state": "CA",
      "manufacturer_link_flag": "Y",
      "manufacturer_contact_address_2": "",
      "manufacturer_g1_city": "REDWOOD CITY",
      "manufacturer_contact_address_1": "150 SHORELINE DRIVE",
      "manufacturer_contact_pcity": "57455106",
      "event_type": "Injury",
      "report_number": "3014447948-2023-00015",
      "type_of_report": [
        "Initial submission"
      ],
      "product_problem_flag": "N",
      "date_received": "20230811",
      "manufacturer_address_2": "",
      "pma_pmn_number": "K203614",
      "date_of_event": "20230614",
      "reprocessed_and_reused_flag": "N",
      "manufacturer_address_1": "",
      "exemption_number": "",
      "manufacturer_contact_zip_code": "94065",
      "reporter_occupation_code": "PHYSICIAN",
      "manufacturer_contact_plocal": "5745510671",
      "noe_summarized": "1",
      "manufacturer_contact_l_name": "SMITH",
      "source_type": [
        "Health Professional",
        "Company representation"
      ],
      "distributor_zip_code_ext": "",
      "manufacturer_g1_postal_code": "94065",
      "manufacturer_g1_state": "CA",
      "reporter_country_code": "US",
      "manufacturer_contact_area_code": "574",
      "date_added": "20230811",
      "manufacturer_contact_f_name": "ANDRIA",
      "device_date_of_manufacturer": "20230323",
      "previous_use_code": "I",
      "device": [
        {
          "device_event_key": "",
          "implant_flag": "",
          "date_removed_flag": "",
          "device_sequence_number": "1085569",
          "implant_date_year": "",
          "date_removed_year": "",
          "serviced_by_3rd_party_flag": "U",
          "date_received": "20230811",
          "brand_name": "MONARCH PLATFORM",
          "generic_name": "BRONCHOSCOPE (FLEXIBLE OR RIGID) AND ACCESSORIES",
          "manufacturer_d_name": "AURIS HEALTH, INC.",
          "manufacturer_d_address_1": "150 SHORELINE DRIVE",
          "manufacturer_d_address_2": "",
          "manufacturer_d_city": "REDWOOD CITY",
          "manufacturer_d_state": "CA",
          "manufacturer_d_zip_code": "94065",
          "manufacturer_d_zip_code_ext": "",
          "manufacturer_d_country": "US",
          "manufacturer_d_postal_code": "94065",
          "device_operator": "HEALTH PROFESSIONAL",
          "model_number": "MBR-000211-A",
          "catalog_number": "",
          "lot_number": "",
          "other_id_number": "",
          "device_availability": "Device was returned to manufacturer",
          "date_returned_to_manufacturer": "20230623",
          "device_report_product_code": "EOQ",
          "device_age_text": "",
          "device_evaluated_by_manufacturer": "Y",
          "combination_product_flag": "N",
          "udi_di": "B634MBR000211A1",
          "udi_public": "+B634MBR000211A1/14D202310230",
          "openfda": {
            "device_name": "Bronchoscope (Flexible Or Rigid)",
            "medical_specialty_description": "Ear, Nose, Throat",
            "regulation_number": "874.4680",
            "device_class": "2"
          }
        }
      ],
      "product_problems": [
        "Adverse Event Without Identified Device or Use Problem",
        "Adverse Event Without Identified Device or Use Problem"
      ],
      "reporter_state_code": "NC",
      "manufacturer_zip_code": "",
      "suppl_dates_mfr_received": "",
      "mfr_report_type": "Thirty-Day",
      "manufacturer_contact_country": "US",
      "date_changed": "20250821",
      "health_professional": "Y",
      "summary_report_flag": "N",
      "manufacturer_g1_zip_code_ext": "",
      "manufacturer_contact_extension": "",
      "manufacturer_city": "",
      "manufacturer_contact_phone_number": "5745",
      "patient": [
        {
          "patient_sequence_number": "1",
          "date_received": "20230811",
          "sequence_number_treatment": [
            ""
          ],
          "sequence_number_outcome": [
            "Required Intervention",
            " H"
          ],
          "patient_age": "",
          "patient_sex": "Unknown",
          "patient_weight": "",
          "patient_ethnicity": "",
          "patient_race": "",
          "patient_problems": [
            "Pneumothorax",
            "Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available",
            "Pneumothorax",
            "Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available"
          ]
        }
      ],
      "distributor_city": "",
      "date_report": "20230811",
      "initial_report_to_fda": "",
      "distributor_state": "",
      "event_key": "",
      "manufacturer_g1_country": "US",
      "manufacturer_contact_city": "REDWOOD CITY",
      "mdr_report_key": "17509786",
      "removal_correction_number": "",
      "number_devices_in_event": "",
      "date_manufacturer_received": "20230614",
      "manufacturer_name": "",
      "report_source_code": "Manufacturer report",
      "remedial_action": [
        ""
      ],
      "manufacturer_g1_zip_code": "94065",
      "report_to_manufacturer": "",
      "manufacturer_zip_code_ext": "",
      "manufacturer_g1_name": "AURIS HEALTH, INC.",
      "adverse_event_flag": "Y",
      "distributor_address_1": "",
      "manufacturer_state": "",
      "distributor_address_2": "",
      "manufacturer_postal_code": "",
      "single_use_flag": "N",
      "manufacturer_country": "",
      "mdr_text": [
        {
          "mdr_text_key": "321044051",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "0",
          "text": "THE SUBJECT SCOPE WAS CONNECTED TO A BENCH TEST FIXTURE TO VERIFY ELECTRICAL FUNCTIONALITY OF THE CAMERA, LIGHT EMITTING DIODE (LED), AND ELECTROMAGNETIC SENSORS (EM). THE SCOPE TIP WAS MANUALLY ARTICULATED WHILE MONITORING THE RESISTANCE OF EACH SENSOR TO CONFIRM THAT THERE WAS NO INTERMITTENT OPEN ON EITHER SENSOR OR CAMERA IMAGE DEGRADATION. THE RESULTS SHOWED OBSERVED BOTH SENSORS TO BE WITHIN SPECIFICATION. A CLOSER INSPECTION OF THE SCOPE HANDLE, SHAFT, CABLE, AND CONNECTOR OBSERVED NO EXTERNAL PHYSICAL DAMAGE THAT COULD CONTRIBUTE TO THE REPORTED ISSUE. THE RESULTS SHOWED THE BRONCHOSCOPE TO BE OPERATING AS EXPECTED. A REVIEW OF THE CALIBRATION DATA OBTAINED FROM PRODUCTION FINAL ACCEPTANCE TESTING REVEALED ALL ACCEPTANCE CRITERIA WERE MET AND NO ANOMALIES FOUND. BASED ON THE RESULTS FROM THE EXAMINATION, THE PRODUCT MET SPECIFICATIONS. A REVIEW OF SIMILAR INVESTIGATIONS WITH SIMILAR REPORTED ISSUE (1200 FAULT OR EM SENSING ISSUE) HAS NOTED THAT THIS IS A KNOWN ISSUE AND HAVE NOT ESTABLISHED A POSSIBLE ROOT CAUSE. THE INCIDENT WILL CONTINUE TO BE MONITORED IN REGULAR TREND REVIEW MEETINGS."
        },
        {
          "mdr_text_key": "321044052",
          "text_type_code": "Description of Event or Problem",
          "patient_sequence_number": "0",
          "text": "IT WAS REPORTED THAT AFTER A SUCCESSFUL DIAGNOSTIC PROCEDURE USING THE MONARCH BRONCHOSCOPY SYSTEM, A PNEUMOTHORAX AND PNEUMOMEDIASTINUM WERE NOTED POST-PROCEDURE. A CHEST TUBE WAS PLACED AND THE PATIENT WAS ADMITTED TO THE HOSPITAL. THE PNEUMOTHORAX AND PNEUMOMEDIASTINUM RESOLVED AND THE PATIENT WAS DISCHARGED."
        }
      ],
      "number_patients_in_event": "",
      "distributor_name": "",
      "manufacturer_g1_address_1": "150 SHORELINE DRIVE",
      "distributor_zip_code": "",
      "manufacturer_contact_postal_code": "94065",
      "manufacturer_contact_exchange": "574",
      "manufacturer_contact_pcountry": "",
      "suppl_dates_fda_received": ""
    }
  ]
}