  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-08",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "manufacturer_contact_zip_ext": "",
      "manufacturer_g1_address_2": "",
      "event_location": "I",
      "report_to_fda": "*",
      "manufacturer_contact_t_name": "",
      "manufacturer_contact_state": "",
      "manufacturer_link_flag": "Y",
      "manufacturer_contact_address_2": "",
      "manufacturer_g1_city": "",
      "manufacturer_contact_address_1": "",
      "manufacturer_contact_pcity": "",
      "event_type": "Injury",
      "report_number": "3014447948-2021-00017",
      "type_of_report": [
        "Initial submission",
        "Followup"
      ],
      "product_problem_flag": "N",
      "date_received": "20210604",
      "manufacturer_address_2": "",
      "pma_pmn_number": "K173760",
      "date_of_event": "20210507",
      "reprocessed_and_reused_flag": "N",
      "manufacturer_address_1": "",
      "exemption_number": "",
      "manufacturer_contact_zip_code": "",
      "reporter_occupation_code": "OTHER HEALTH CARE PROFESSIONAL",
      "manufacturer_contact_plocal": "",
      "noe_summarized": "1",
      "manufacturer_contact_l_name": "",
      "source_type": [
        "COMPANY REPRESENTATIVE",
        "HEALTH"
      ],
      "distributor_zip_code_ext": "",
      "manufacturer_g1_postal_code": "",
      "manufacturer_g1_state": "",
      "reporter_country_code": "US",
      "manufacturer_contact_area_code": "",
      "date_added": "20210604",
      "manufacturer_contact_f_name": "",
      "previous_use_code": "",
      "device": [
        {
          "device_event_key": "",
          "implant_flag": "",
          "date_removed_flag": "",
          "device_sequence_number": "837795",
          "implant_date_year": "",
          "date_removed_year": "",
          "serviced_by_3rd_party_flag": "U",
          "date_received": "20210604",
          "brand_name": "MONARCH ENDOSCOPY PLATFORM (MONARCH PLATFORM)",
          "generic_name": "BRONCHOSCOPE (FLEXIBLE OR RIGID) AND ACCESSORIES",
          "manufacturer_d_name": "AURIS HEALTH, INC.",
          "manufacturer_d_address_1": "150 SHORELINE DRIVE",
          "manufacturer_d_address_2": "",
          "manufacturer_d_city": "REDWOOD CITY",
          "manufacturer_d_state": "CA",
          "manufacturer_d_zip_code": "",
          "manufacturer_d_zip_code_ext": "",
          "manufacturer_d_country": "",
          "manufacturer_d_postal_code": "",
          "device_operator": "I",
          "model_number": "MON-000005",
          "catalog_number": "",
          "lot_number": "",
          "other_id_number": "",
          "device_availability": "No",
          "device_report_product_code": "EOQ",
          "device_age_text": "DA",
          "device_evaluated_by_manufacturer": "",
          "combination_product_flag": "N",
          "udi_di": "",
          "udi_public": "",
          "openfda": {
            "device_name": "Bronchoscope (Flexible Or Rigid)",
            "medical_specialty_description": "Ear, Nose, Throat",
            "regulation_number": "874.4680",
            "device_class": "2"
          }
        }
      ],
      "product_problems": [
        "Adverse Event Without Identified Device or Use Problem",
        "Adverse Event Without Identified Device or Use Problem"
      ],
      "reporter_state_code": "IN",
      "manufacturer_zip_code": "",
      "suppl_dates_mfr_received": "06/14/2021",
      "mfr_report_type": "",
      "manufacturer_contact_country": "",
      "date_changed": "20250813",
      "health_professional": "",
      "summary_report_flag": "N",
      "manufacturer_g1_zip_code_ext": "",
      "manufacturer_contact_extension": "",
      "manufacturer_city": "",
      "manufacturer_contact_phone_number": "",
      "patient": [
        {
          "patient_sequence_number": "1",
          "date_received": "20210604",
          "sequence_number_treatment": [
            ""
          ],
          "sequence_number_outcome": [
            "Hospitalization",
            " R"
          ],
          "patient_age": "",
          "patient_sex": "",
          "patient_weight": "",
          "patient_ethnicity": "",
          "patient_race": "",
          "patient_problems": [
            "Cardiac Arrest",
            "Pneumothorax",
            "Cardiac Arrest",
            "Pneumothorax"
          ]
        }
      ],
      "distributor_city": "",
      "date_report": "20210507",
      "initial_report_to_fda": "",
      "distributor_state": "",
      "event_key": "",
      "manufacturer_g1_country": "",
      "manufacturer_contact_city": "",
      "mdr_report_key": "11939899",
      "removal_correction_number": "",
      "number_devices_in_event": "",
      "date_manufacturer_received": "20210507",
      "manufacturer_name": "",
      "report_source_code": "Manufacturer report",
      "remedial_action": [
        ""
      ],
      "manufacturer_g1_zip_code": "",
      "report_to_manufacturer": "",
      "manufacturer_zip_code_ext": "",
      "manufacturer_g1_name": "",
      "adverse_event_flag": "Y",
      "distributor_address_1": "",
      "manufacturer_state": "",
      "distributor_address_2": "",
      "manufacturer_postal_code": "",
      "single_use_flag": "",
      "manufacturer_country": "",
      "mdr_text": [
        {
          "mdr_text_key": "324436946",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "0",
          "text": "CORRECTED MANUFACTURER ADDRESS STREET: 150 SHORELINE DRIVE MANUFACTURER ADDRESS STREET: 150 SHORELINE DRIVE."
        },
        {
          "mdr_text_key": "254330150",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "1",
          "text": "THE DEVICE WAS NOT RETURNED FOR EVALUATION. THERE WAS NO ALLEGATION OF DEVICE FAILURE. RISK OF PNEUMOTHORAX IS DOCUMENTED IN 105-000299-01, REV D, MONARCH BRONCH RISK MANAGEMENT REPORT AND IS DEEMED TO BE ACCEPTABLE. BASED ON THE INFORMATION AVAILABLE FOR THIS COMPLAINT, THE ROOT CAUSE OF THE REPORTED EVENT IS RELATED TO A KNOWN INHERENT RISK OF THE DEVICE AND PROCEDURE AS DOCUMENTED IN THE LABELING. NO CORRECTIVE ACTION IS REQUIRED AT THIS TIME. THE REPORTED EVENT WILL CONTINUE TO BE MONITORED THROUGH REGULAR COMPLAINT TREND REVIEW."
        },
        {
          "mdr_text_key": "254330151",
          "text_type_code": "Description of Event or Problem",
          "patient_sequence_number": "1",
          "text": "IT WAS REPORTED THAT DURING A MONARCH-ASSISTED BRONCHOSCOPY PROCEDURE THE PATIENT EXPERIENCED A PNEUMOTHORAX. THE LOCATION WAS RIGHT UPPER LOBE. THE LOCATION OF THE PNEUMOTHORAX WAS RIGHT SIDE. DURING THE PROCEDURE THE PATIENT WENT INTO A COMPLETE HEART BLOCK AND BECAME HYPOTENSIVE. EPINEPHRINE WAS PUSHED INTO THE PATIENT¿S INTRAVENOUS TO TACKLE HYPOTENSION AND THE SCOPE WAS REMOVED IMMEDIATELY. THE CUSTOMER TOOK THE SCOPE OFF THE ROBOTIC ARMS AT THIS TIME AND WENT ON TO REMOVE THE SCOPE OUT OF PATIENT MANUALLY. THE PATIENT SUBSEQUENTLY BECAME STABLE, E.G., SHOWED INFERIOR WALL ACUTE MYOCARDIAL INFARCTION (AMI). THE PATIENT WENT TO THE CARDIAC CATHETERIZATION LAB IMMEDIATELY AND HAD AN EMERGENT ANGIOGRAM. THE PATIENT HAS RECOVERED AND HAS BEEN DISCHARGED."
        }
      ],
      "number_patients_in_event": "",
      "distributor_name": "",
      "manufacturer_g1_address_1": "",
      "distributor_zip_code": "",
      "manufacturer_contact_postal_code": "",
      "manufacturer_contact_exchange": "",
      "manufacturer_contact_pcountry": "",
      "suppl_dates_fda_received": "06/14/2021"
    }
  ]
}