  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-08",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "manufacturer_contact_zip_ext": "",
      "manufacturer_g1_address_2": "",
      "event_location": "",
      "report_to_fda": "N",
      "manufacturer_contact_t_name": "MR.",
      "manufacturer_contact_state": "FL",
      "manufacturer_link_flag": "Y",
      "manufacturer_contact_address_2": "",
      "manufacturer_g1_city": "MAUGUIO, LANGUEDOC-ROUSSILLON",
      "manufacturer_contact_address_1": "1520 TRADEPORT DRIVE",
      "manufacturer_contact_pcity": "90474144",
      "event_type": "Injury",
      "report_number": "3009185973-2022-00006",
      "type_of_report": [
        "Initial submission",
        "Followup"
      ],
      "product_problem_flag": "Y",
      "date_received": "20220202",
      "manufacturer_address_2": "",
      "pma_pmn_number": "K200511",
      "date_of_event": "20211213",
      "reprocessed_and_reused_flag": "N",
      "manufacturer_address_1": "",
      "exemption_number": "",
      "manufacturer_contact_zip_code": "32218",
      "reporter_occupation_code": "OTHER HEALTH CARE PROFESSIONAL",
      "manufacturer_contact_plocal": "9047414400",
      "noe_summarized": "1",
      "manufacturer_contact_l_name": "SHARMA",
      "source_type": [
        "Health Professional",
        "Company representation"
      ],
      "distributor_zip_code_ext": "",
      "manufacturer_g1_postal_code": "34130",
      "manufacturer_g1_state": "",
      "reporter_country_code": "FR",
      "manufacturer_contact_area_code": "904",
      "date_added": "20220202",
      "manufacturer_contact_f_name": "JAY",
      "device_date_of_manufacturer": "20200916",
      "previous_use_code": "R",
      "device": [
        {
          "device_event_key": "",
          "implant_flag": "",
          "date_removed_flag": "",
          "device_sequence_number": "1316395",
          "implant_date_year": "",
          "date_removed_year": "",
          "serviced_by_3rd_party_flag": "U",
          "date_received": "20220202",
          "brand_name": "ROSA ONE",
          "generic_name": "COMPUTER-ASSISTED SURGICAL DEVICE",
          "manufacturer_d_name": "MEDTECH SAS",
          "manufacturer_d_address_1": "432 RUE DU RAJOL",
          "manufacturer_d_address_2": "",
          "manufacturer_d_city": "MAUGUIO, LANGUEDOC-ROUSSILLON",
          "manufacturer_d_state": "",
          "manufacturer_d_zip_code": "34130",
          "manufacturer_d_zip_code_ext": "",
          "manufacturer_d_country": "FR",
          "manufacturer_d_postal_code": "34130",
          "device_operator": "HEALTH PROFESSIONAL",
          "model_number": "ROSA ONE",
          "catalog_number": "ROSAS00201",
          "lot_number": "3.1.5.28",
          "other_id_number": "",
          "device_availability": "Yes",
          "device_report_product_code": "HAW",
          "device_age_text": "DA",
          "device_evaluated_by_manufacturer": "R",
          "combination_product_flag": "N",
          "udi_di": "",
          "udi_public": "",
          "openfda": {
            "device_name": "Neurological Stereotaxic Instrument",
            "medical_specialty_description": "Neurology",
            "regulation_number": "882.4560",
            "device_class": "2"
          }
        }
      ],
      "product_problems": [
        "Imprecision",
        "Imprecision"
      ],
      "reporter_state_code": "",
      "manufacturer_zip_code": "",
      "suppl_dates_mfr_received": "02/23/2022",
      "mfr_report_type": "Thirty-Day",
      "manufacturer_contact_country": "US",
      "date_changed": "20250807",
      "health_professional": "Y",
      "summary_report_flag": "N",
      "manufacturer_g1_zip_code_ext": "",
      "manufacturer_contact_extension": "",
      "manufacturer_city": "",
      "manufacturer_contact_phone_number": "9047",
      "patient": [
        {
          "patient_sequence_number": "1",
          "date_received": "20220202",
          "sequence_number_treatment": [
            ""
          ],
          "sequence_number_outcome": [
            "Other"
          ],
          "patient_age": "",
          "patient_sex": "Unknown",
          "patient_weight": "",
          "patient_ethnicity": "",
          "patient_race": "",
          "patient_problems": [
            "No Clinical Signs, Symptoms or Conditions",
            "No Clinical Signs, Symptoms or Conditions"
          ]
        }
      ],
      "distributor_city": "",
      "date_report": "20220228",
      "initial_report_to_fda": "No",
      "distributor_state": "",
      "event_key": "",
      "manufacturer_g1_country": "FR",
      "manufacturer_contact_city": "JACKSONVILLE",
      "mdr_report_key": "13421123",
      "removal_correction_number": "N/A",
      "number_devices_in_event": "",
      "date_manufacturer_received": "20220103",
      "manufacturer_name": "",
      "report_source_code": "Manufacturer report",
      "remedial_action": [
        ""
      ],
      "manufacturer_g1_zip_code": "34130",
      "report_to_manufacturer": "",
      "manufacturer_zip_code_ext": "",
      "manufacturer_g1_name": "MEDTECH SAS",
      "adverse_event_flag": "Y",
      "distributor_address_1": "",
      "manufacturer_state": "",
      "distributor_address_2": "",
      "manufacturer_postal_code": "",
      "single_use_flag": "N",
      "manufacturer_country": "",
      "mdr_text": [
        {
          "mdr_text_key": "284866122",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "0",
          "text": "THE DEVICE HAS NOT BEEN EVALUATED YET FOR INVESTIGATION PURPOSE. ONCE THE EVALUATION IS PERFORMED, A FOLLOW-UP MEDWATCH REPORT WILL BE SUBMITTED. UNIQUE IDENTIFIER (UDI) #: (B)(4)."
        },
        {
          "mdr_text_key": "284866123",
          "text_type_code": "Description of Event or Problem",
          "patient_sequence_number": "0",
          "text": "CONCERNING THE 3 BIOPSIES PERFORMED, THE PROCEDURE DID NOT POSE ANY PARTICULAR PROBLEM, THE FIXATION WAS WITH A MAYFIELD HEAD HOLDER IN CLASSIC DECUBITUS, THERE WAS NO HEMORRHAGIC COMPLICATION OBJECTIFIED AT THE POSTOPERATIVE CONTROL CT SCAN. ON THE OTHER HAND, THE ANALYSIS OF THE SAMPLES WAS NEGATIVE, REQUIRING A SECOND SURGICAL INTERVENTION TO OBTAIN THE DIAGNOSIS, AND THEREFORE A DELAY IN ONCOLOGICAL MANAGEMENT OF ABOUT ONE MONTH."
        },
        {
          "mdr_text_key": "328253521",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "0",
          "text": "A FULL ANALYSIS OF THE DEVICE DATA LOGS AND OF THE PATIENT EXAMS HAS BEEN PERFORMED. THIS ANALYSIS CONCLUDED THAT THE FUSION OF THE POST-OPERATIVE SCANS TO THE PRE-OPERATIVE SCANS WAS UNSUCCESSFUL. THEREFORE, THE INACCURACY AT THE ENTRY POINT COULD NOT BE CONFIRMED. MOREOVER, THE USER DID NOT VERIFY EITHER THE ACCURACY AT THE ENTRY POINT ON THE POST-OPERATIVE SCANS, BUT ONLY NOTICED AN INACCURACY AT THE TARGET POINT. THIS IS MAINLY DEPENDENT ON ELEMENTS OTHER THAT THE ROSA DEVICE, SUCH AS THE METHOD OF IMPLANTATION. IT CAN BE NOTED THAT THE AUTOMATIC SCAN WAS NOT CLEARLY VISIBLE ON THE MATCHING FRAME. THE REST OF THE REGISTRATION WAS PERFORMED CORRECTLY. ADDITIONALLY, ONE HEAD HOLDER USED ON SITE WAS FOUND TO BE DEFECTIVE, AND MAY HAVE BEEN USED FOR THE CASE. THESE ELEMENTS COULD HAVE CONTRIBUTED TO A POTENTIAL INACCURACY AT THE ENTRY POINT. NO FAILURE OF THE DEVICE WAS FOUND DURING ANALYSIS. BASED ON THE INVESTIGATION PERFORMED, THE TECHNICAL ROOT CAUSE OF THE EVENT CANNOT BE DETERMINED. CORRECTED DATA: - B4 DATE OF THIS REPORT. - G3 DATE RECEIVED BY MANUFACTURER . - H2 IF FOLLOW-UP, WHAT TYPE . - H3 DEVICE EVALUATED BY MANUFACTURER. - H6 ADVERSE EVENT PROBLEM. - H10 ADDITIONAL NARRATIVES/DATA."
        },
        {
          "mdr_text_key": "328253522",
          "text_type_code": "Description of Event or Problem",
          "patient_sequence_number": "0",
          "text": "CONCERNING THE 3 BIOPSIES PERFORMED, THE PROCEDURE DID NOT POSE ANY PARTICULAR PROBLEM, THE FIXATION WAS WITH A MAYFIELD HEAD HOLDER IN CLASSIC DECUBITUS, THERE WAS NO HEMORRHAGIC COMPLICATION OBJECTIFIED AT THE POSTOPERATIVE CONTROL CT SCAN. ON THE OTHER HAND, THE ANALYSIS OF THE SAMPLES WAS NEGATIVE, REQUIRING A SECOND SURGICAL INTERVENTION TO OBTAIN THE DIAGNOSIS, AND THEREFORE A DELAY IN ONCOLOGICAL MANAGEMENT OF ABOUT ONE MONTH."
        }
      ],
      "number_patients_in_event": "",
      "distributor_name": "",
      "manufacturer_g1_address_1": "432 RUE DU RAJOL",
      "distributor_zip_code": "",
      "manufacturer_contact_postal_code": "32218",
      "manufacturer_contact_exchange": "904",
      "manufacturer_contact_pcountry": "",
      "suppl_dates_fda_received": "02/28/2022"
    }
  ]
}