{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-08",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "manufacturer_contact_zip_ext": "",
      "manufacturer_g1_address_2": "",
      "event_location": "I",
      "report_to_fda": "*",
      "manufacturer_contact_t_name": "",
      "manufacturer_contact_state": "",
      "manufacturer_link_flag": "Y",
      "manufacturer_contact_address_2": "",
      "manufacturer_g1_city": "",
      "manufacturer_contact_address_1": "",
      "manufacturer_contact_pcity": "",
      "event_type": "Injury",
      "report_number": "3005075696-2020-00139",
      "type_of_report": [
        "Initial submission"
      ],
      "product_problem_flag": "N",
      "date_received": "20201202",
      "manufacturer_address_2": "",
      "pma_pmn_number": "K182077",
      "date_of_event": "20201022",
      "reprocessed_and_reused_flag": "N",
      "manufacturer_address_1": "",
      "exemption_number": "",
      "manufacturer_contact_zip_code": "",
      "reporter_occupation_code": "PHYSICIAN",
      "manufacturer_contact_plocal": "",
      "noe_summarized": "1",
      "manufacturer_contact_l_name": "",
      "source_type": [
        "HEALTH PROFESSIONAL",
        "LITERATUR"
      ],
      "distributor_zip_code_ext": "",
      "manufacturer_g1_postal_code": "",
      "manufacturer_g1_state": "",
      "reporter_country_code": "US",
      "manufacturer_contact_area_code": "",
      "date_added": "20201202",
      "manufacturer_contact_f_name": "",
      "previous_use_code": "",
      "device": [
        {
          "device_event_key": "",
          "implant_flag": "",
          "date_removed_flag": "",
          "device_sequence_number": "1397715",
          "implant_date_year": "",
          "date_removed_year": "",
          "serviced_by_3rd_party_flag": "",
          "date_received": "20201202",
          "brand_name": "MAZOR X STEALTH EDITION",
          "generic_name": "ORTHOPEDIC STEREOTAXIC INSTRUMENT",
          "manufacturer_d_name": "MAZOR ROBOTICS LTD",
          "manufacturer_d_address_1": "5 SHACHAM STREET",
          "manufacturer_d_address_2": "P.O. BOX 3104",
          "manufacturer_d_city": "CAESAREA HEFA,IL",
          "manufacturer_d_state": "",
          "manufacturer_d_zip_code": "30795",
          "manufacturer_d_zip_code_ext": "67",
          "manufacturer_d_country": "IS",
          "manufacturer_d_postal_code": "3079567",
          "device_operator": "HEALTH PROFESSIONAL",
          "model_number": "TPL0059",
          "catalog_number": "TPL0059",
          "lot_number": "",
          "other_id_number": "",
          "device_availability": "No",
          "device_report_product_code": "OLO",
          "device_age_text": "",
          "device_evaluated_by_manufacturer": "",
          "combination_product_flag": "N",
          "udi_di": "07290109183213",
          "udi_public": "07290109183213",
          "openfda": {
            "device_name": "Orthopedic Stereotaxic Instrument",
            "medical_specialty_description": "Neurology",
            "regulation_number": "882.4560",
            "device_class": "2"
          }
        }
      ],
      "product_problems": [
        "Adverse Event Without Identified Device or Use Problem",
        "Adverse Event Without Identified Device or Use Problem"
      ],
      "reporter_state_code": "MA",
      "manufacturer_zip_code": "",
      "suppl_dates_mfr_received": "",
      "mfr_report_type": "Thirty-Day",
      "manufacturer_contact_country": "",
      "date_changed": "20250818",
      "health_professional": "",
      "summary_report_flag": "N",
      "manufacturer_g1_zip_code_ext": "",
      "manufacturer_contact_extension": "",
      "manufacturer_city": "",
      "manufacturer_contact_phone_number": "",
      "patient": [
        {
          "patient_sequence_number": "1",
          "date_received": "20201202",
          "sequence_number_treatment": [
            ""
          ],
          "sequence_number_outcome": [
            "Required Intervention"
          ],
          "patient_age": "",
          "patient_sex": "",
          "patient_weight": "",
          "patient_ethnicity": "",
          "patient_race": "",
          "patient_problems": [
            "Fever",
            "Seroma",
            "Post Operative Wound Infection",
            "Fluid Discharge",
            "Fever",
            "Seroma",
            "Post Operative Wound Infection",
            "Fluid Discharge"
          ]
        }
      ],
      "distributor_city": "",
      "date_report": "20201202",
      "initial_report_to_fda": "",
      "distributor_state": "",
      "event_key": "",
      "manufacturer_g1_country": "",
      "manufacturer_contact_city": "",
      "mdr_report_key": "10935340",
      "removal_correction_number": "",
      "number_devices_in_event": "",
      "date_manufacturer_received": "20201106",
      "manufacturer_name": "",
      "report_source_code": "Manufacturer report",
      "remedial_action": [
        ""
      ],
      "manufacturer_g1_zip_code": "",
      "report_to_manufacturer": "",
      "manufacturer_zip_code_ext": "",
      "manufacturer_g1_name": "",
      "adverse_event_flag": "Y",
      "distributor_address_1": "",
      "manufacturer_state": "",
      "distributor_address_2": "",
      "manufacturer_postal_code": "",
      "single_use_flag": "",
      "manufacturer_country": "",
      "mdr_text": [
        {
          "mdr_text_key": "219348185",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "1",
          "text": "PLEASE NOTE THAT THIS DATE IS BASED OFF THE DATE OF PUBLICATION OF THE ARTICLE AS THE ACTUAL EVENT DATE WAS NOT PROVIDED. THE REPORTED EVENT WAS FROM THE FOLLOWING LITERATURE ARTICLE: GONZALEZ D, GHESSESE S, COOK D, HEDEQUIST D. INITIAL INTRAOPERATIVE EXPERIENCE WITH ROBOTIC-ASSISTED PEDICLE SCREW PLACEMENT WITH STEALTH NAVIGATION IN PEDIATRIC SPINE DEFORMITY: AN EVALUATION OF THE FIRST 40 CASES. JOURNAL OF ROBOTIC SURGERY. 2020. HTTPS://DOI.OR G/10.1007/S11701-020-01159-3. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED."
        },
        {
          "mdr_text_key": "219348186",
          "text_type_code": "Description of Event or Problem",
          "patient_sequence_number": "1",
          "text": "ABSTRACT: PEDICLE SCREW FIXATION IN PEDIATRIC SPINE SURGERY HAS BECOME COMMON PRACTICE GIVEN THE FIXATION STABILITY AND IMPROVED CURVE CORRECTION. HOWEVER, DUE TO PROXIMITY TO VITAL STRUCTURES, ACCURACY IS PARAMOUNT. LITERATURE HAS REPORTED ACCURACY RATES FROM 87.5 TO 90% USING TRADITIONAL FREEHAND TECHNIQUES. THIS STUDY PRESENTS OUR INITIAL EXPERIENCE WITH PEDICLE SCREW PLACEMENT USING THE NEWEST GENERATION OF SPINAL ROBOTICS FOR TREATMENT OF PEDIATRIC SPINAL DEFORMITY. A COHORT OF PATIENTS, AGED 8¿21 YEARS, UNDERGOING SPINAL FUSION SURGERY USING ROBOTIC-ASSISTED TECHNOLOGY WAS REVIEWED. DIAGNOSES, COBB ANGLES, SURGICAL TIME, ROBOT TIME, NUMBER OF SCREWS PLACED, AND COMPLICATIONS WERE RECORDED. ACCURACY OF SCREW PLACEMENT WAS ASSESSED BASED ON ANALYSIS OF SUCCESSFUL SCREW EXECUTION, EVALUATION SCREW POSITION USING INTRAOPERATIVE FLUOROSCOPY AND POST-OPERATIVE RADIOGRAPHS, AND CLINICAL EVALUATION. THE AVERAGE AGE WAS 14.5 YEARS. PREVALENT DIAGNOSES INCLUDED IDIOPATHIC (65%) AND NEUROMUSCULAR SCOLIOSIS (13%). MEAN PREOPERATIVE CURVE MEASURED 66.8°. THE MEDIAN TIME FOR OPERATION WAS 235 MINUTES WITH MEDIANS OF 8 LEVELS FUSED AND 5 SCREWS PLACED PER PATIENT. OF THE 314 SCREWS PLACED, WE RECORDED A 98.7% ACCURACY RATE. LATERAL DEVIATION WAS THE MOST COMMON CAUSE OF MALPOSITIONING. POST-OPERATIVE PLAIN FILMS REVEALED NO GROSSLY MISPLACED SCREWS. THERE WERE NO PERIOPERATIVE NEUROLOGIC DEFICITS OR MALPOSITIONED SCREWS REQUIRING REOPERATION. THIS IS THE FIRST REPORTED SERIES OF NAVIGATED SPINAL ROBOTICS USED FOR PEDICLE SCREW PLACEMENT IN CHILDREN. OUR CLINICAL SUCCESS RATE WAS 98.7% AND THERE WERE NO CLINICALLY RELEVANT SCREW RELATED COMPLICATIONS. THE STUDY SHOWS PROMISING INITIAL RESULTS OF COMBINED ROBOTIC-NAVIGATION TECHNIQUES IN PEDIATRIC PATIENTS. REPORTED EVENTS: ONE PATIENT EXPERIENCE WOUND DRAINAGE AND FEVER POSTOPERATIVELY FROM SUPERFICIAL WOUND INFECTIONS. THE PATIENT WAS TAKEN BACK TO THE OPERATING ROOM FOR EXPLORATION AND DEBRIDEMENT. THERE WERE NO FURTHER COMPLICATIONS. ONE PATIENT EXPERIENCE WOUND DRAINAGE AND FEVER POSTOPERATIVELY FROM SUPERFICIAL WOUND INFECTIONS. THE PATIENT WAS TAKEN BACK TO THE OPERATING ROOM FOR EXPLORATION AND DEBRIDEMENT. FLUID COLLECTIONS WERE SEEN SUBCUTANEOUSLY WHICH EXTENDED TO THE IMPLANTS IN ONE PATIENT. THERE WERE NO FURTHER COMPLICATIONS."
        }
      ],
      "number_patients_in_event": "",
      "distributor_name": "",
      "manufacturer_g1_address_1": "",
      "distributor_zip_code": "",
      "manufacturer_contact_postal_code": "",
      "manufacturer_contact_exchange": "",
      "manufacturer_contact_pcountry": "",
      "suppl_dates_fda_received": ""
    }
  ]
}