  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-08",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "manufacturer_contact_zip_ext": "",
      "manufacturer_g1_address_2": "",
      "event_location": "",
      "report_to_fda": "",
      "manufacturer_contact_t_name": "",
      "manufacturer_contact_state": "CA",
      "manufacturer_link_flag": "Y",
      "manufacturer_contact_address_2": "",
      "manufacturer_g1_city": "Santa Clara",
      "manufacturer_contact_address_1": "3410 Central Expressway",
      "manufacturer_contact_pcity": "+1(408)5",
      "event_type": "Injury",
      "report_number": "2955842-2026-35378",
      "type_of_report": [
        "Initial submission"
      ],
      "product_problem_flag": "N",
      "date_received": "20260817",
      "manufacturer_address_2": "",
      "pma_pmn_number": "",
      "date_of_event": "20250731",
      "reprocessed_and_reused_flag": "N",
      "manufacturer_address_1": "",
      "exemption_number": "",
      "manufacturer_contact_zip_code": "95051",
      "reporter_occupation_code": "PHYSICIAN",
      "manufacturer_contact_plocal": "+1(408)523-2100",
      "noe_summarized": "1",
      "manufacturer_contact_l_name": "Nielson",
      "source_type": [
        "Other",
        "Foreign",
        "Literature",
        "Health Professional"
      ],
      "distributor_zip_code_ext": "",
      "manufacturer_g1_postal_code": "95051",
      "manufacturer_g1_state": "CA",
      "reporter_country_code": "US",
      "manufacturer_contact_area_code": "",
      "date_added": "20260817",
      "manufacturer_contact_f_name": "Izabel",
      "previous_use_code": "R",
      "device": [
        {
          "device_event_key": "",
          "implant_flag": "",
          "date_removed_flag": "",
          "device_sequence_number": "699494",
          "implant_date_year": "",
          "date_removed_year": "",
          "serviced_by_3rd_party_flag": "",
          "date_received": "20260817",
          "brand_name": "da Vinci",
          "generic_name": "da Vinci",
          "manufacturer_d_name": "INTUITIVE SURGICAL, INC",
          "manufacturer_d_address_1": "3410 Central Expressway",
          "manufacturer_d_address_2": "",
          "manufacturer_d_city": "Santa Clara",
          "manufacturer_d_state": "CA",
          "manufacturer_d_zip_code": "95051",
          "manufacturer_d_zip_code_ext": "",
          "manufacturer_d_country": "US",
          "manufacturer_d_postal_code": "95051",
          "device_operator": "HEALTH PROFESSIONAL",
          "model_number": "N/A",
          "catalog_number": "N/A",
          "lot_number": "N/A",
          "other_id_number": "",
          "device_availability": "No",
          "device_report_product_code": "NAY",
          "device_age_text": "",
          "device_evaluated_by_manufacturer": "N",
          "combination_product_flag": "N",
          "udi_di": "",
          "udi_public": "",
          "openfda": {
            "device_name": "System, Surgical, Computer Controlled Instrument",
            "medical_specialty_description": "Gastroenterology, Urology",
            "regulation_number": "876.1500",
            "device_class": "2"
          }
        }
      ],
      "product_problems": [
        "Insufficient Device Problem Information"
      ],
      "reporter_state_code": "",
      "manufacturer_zip_code": "",
      "suppl_dates_mfr_received": "",
      "mfr_report_type": "",
      "manufacturer_contact_country": "US",
      "date_changed": "20260818",
      "health_professional": "Y",
      "summary_report_flag": "N",
      "manufacturer_g1_zip_code_ext": "",
      "manufacturer_contact_extension": "",
      "manufacturer_city": "",
      "manufacturer_contact_phone_number": "",
      "patient": [
        {
          "patient_sequence_number": "1",
          "date_received": "20260817",
          "sequence_number_treatment": [
            "da Vinci Instruments and Accessories"
          ],
          "sequence_number_outcome": [
            "Required Intervention",
            " O"
          ],
          "patient_age": "66 YR",
          "patient_sex": "Female",
          "patient_weight": "",
          "patient_ethnicity": "",
          "patient_race": "",
          "patient_problems": [
            "Hematoma",
            "Pain"
          ]
        }
      ],
      "distributor_city": "",
      "date_report": "20260722",
      "initial_report_to_fda": "No",
      "distributor_state": "",
      "event_key": "",
      "manufacturer_g1_country": "US",
      "manufacturer_contact_city": "Santa Clara",
      "mdr_report_key": "50287215",
      "removal_correction_number": "N/A",
      "number_devices_in_event": "",
      "date_manufacturer_received": "20260722",
      "manufacturer_name": "",
      "report_source_code": "Manufacturer report",
      "remedial_action": [
        "Other"
      ],
      "manufacturer_g1_zip_code": "95051",
      "report_to_manufacturer": "",
      "manufacturer_zip_code_ext": "",
      "manufacturer_g1_name": "INTUITIVE SURGICAL, INC",
      "adverse_event_flag": "Y",
      "distributor_address_1": "",
      "manufacturer_state": "",
      "distributor_address_2": "",
      "manufacturer_postal_code": "",
      "single_use_flag": "N",
      "manufacturer_country": "",
      "mdr_text": [
        {
          "mdr_text_key": "15504405294",
          "text_type_code": "Description of Event or Problem",
          "patient_sequence_number": "0",
          "text": "A review of an article was performed that presented a retrospective review of experiences with robotic sacrocolpopexy procedures. The article compared the outcomes of patients who underwent robotic sacrocolpopexy with (HYST) or without supracervical hysterectomy (no-HYST) group. In the no-HYST group, a number of patients experienced the following complications: One abdominal wall hematoma, one case of ileus, one patient requiring self-catheterization, one reporting pain, one case of occlusive syndrome due to constipation that resolved with medical treatment, and one abdominal wall abscess.The corresponding author was contacted but no response has been received."
        },
        {
          "mdr_text_key": "16004405295",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "0",
          "text": "No investigation could be performed as the article did not provide any specific information regarding the procedure date or da Vinci System identifiers. No image(s) and/or video clip(s) associated with this reported event were reviewed.Citation: Blondeau, A., Chommeloux, M., Haudebert, C., Richard, C., Dubois, A., Penafel, J., Manunta, A., Hascoet, J., & Peyronnet, B. (2025). Robotic sacrocolpopexy with versus without supracervical hysterectomy. International Urogynecology Journal. https://doi.org/10.1007/s00192-025-06253-4Mean BMI: 25.8.NOTE:Due to the lack of specific information regarding the event date associated with the adverse event, the publication date has been used as the event date.The patient demographics provided represent the demographics of the majority population described in the article.The procedures described in the article were performed using an unspecified da Vinci Surgical System device. There is insufficient information to determine the specific system that was used during the procedures with complications; thus the product is reported as Not Applicable (N/A)."
        }
      ],
      "number_patients_in_event": "",
      "distributor_name": "",
      "manufacturer_g1_address_1": "3410 Central Expressway",
      "distributor_zip_code": "",
      "manufacturer_contact_postal_code": "95051",
      "manufacturer_contact_exchange": "",
      "manufacturer_contact_pcountry": "",
      "suppl_dates_fda_received": ""
    }
  ]
}