  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-08",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "manufacturer_contact_zip_ext": "",
      "manufacturer_g1_address_2": "",
      "event_location": "",
      "report_to_fda": "",
      "manufacturer_contact_t_name": "",
      "manufacturer_contact_state": "CA",
      "manufacturer_link_flag": "Y",
      "manufacturer_contact_address_2": "",
      "manufacturer_g1_city": "Santa Clara",
      "manufacturer_contact_address_1": "3410 Central Expressway",
      "manufacturer_contact_pcity": "+1(408)5",
      "event_type": "Injury",
      "report_number": "2955842-2026-33976",
      "type_of_report": [
        "Initial submission"
      ],
      "product_problem_flag": "N",
      "date_received": "20260818",
      "manufacturer_address_2": "",
      "pma_pmn_number": "",
      "date_of_event": "20250707",
      "reprocessed_and_reused_flag": "N",
      "manufacturer_address_1": "",
      "exemption_number": "",
      "manufacturer_contact_zip_code": "95051",
      "reporter_occupation_code": "PHYSICIAN",
      "manufacturer_contact_plocal": "+1(408)523-2100",
      "noe_summarized": "1",
      "manufacturer_contact_l_name": "Nielson",
      "source_type": [
        "Other",
        "Literature"
      ],
      "distributor_zip_code_ext": "",
      "manufacturer_g1_postal_code": "95051",
      "manufacturer_g1_state": "CA",
      "reporter_country_code": "US",
      "manufacturer_contact_area_code": "",
      "date_added": "20260818",
      "manufacturer_contact_f_name": "Izabel",
      "previous_use_code": "R",
      "device": [
        {
          "device_event_key": "",
          "implant_flag": "",
          "date_removed_flag": "",
          "device_sequence_number": "699980",
          "implant_date_year": "",
          "date_removed_year": "",
          "serviced_by_3rd_party_flag": "",
          "date_received": "20260818",
          "brand_name": "da Vinci",
          "generic_name": "da Vinci",
          "manufacturer_d_name": "INTUITIVE SURGICAL, INC",
          "manufacturer_d_address_1": "3410 Central Expressway",
          "manufacturer_d_address_2": "",
          "manufacturer_d_city": "Santa Clara",
          "manufacturer_d_state": "CA",
          "manufacturer_d_zip_code": "95051",
          "manufacturer_d_zip_code_ext": "",
          "manufacturer_d_country": "US",
          "manufacturer_d_postal_code": "95051",
          "device_operator": "HEALTH PROFESSIONAL",
          "model_number": "N/A",
          "catalog_number": "N/A",
          "lot_number": "N/A",
          "other_id_number": "",
          "device_availability": "No",
          "device_report_product_code": "NAY",
          "device_age_text": "",
          "device_evaluated_by_manufacturer": "N",
          "combination_product_flag": "N",
          "udi_di": "",
          "udi_public": "",
          "openfda": {
            "device_name": "System, Surgical, Computer Controlled Instrument",
            "medical_specialty_description": "Gastroenterology, Urology",
            "regulation_number": "876.1500",
            "device_class": "2"
          }
        }
      ],
      "product_problems": [
        "Insufficient Device Problem Information"
      ],
      "reporter_state_code": "PA",
      "manufacturer_zip_code": "",
      "suppl_dates_mfr_received": "",
      "mfr_report_type": "",
      "manufacturer_contact_country": "US",
      "date_changed": "20260818",
      "health_professional": "Y",
      "summary_report_flag": "N",
      "manufacturer_g1_zip_code_ext": "",
      "manufacturer_contact_extension": "",
      "manufacturer_city": "",
      "manufacturer_contact_phone_number": "",
      "patient": [
        {
          "patient_sequence_number": "1",
          "date_received": "20260818",
          "sequence_number_treatment": [
            "da Vinci Instruments and Accessories."
          ],
          "sequence_number_outcome": [
            "Required Intervention"
          ],
          "patient_age": "58 YR",
          "patient_sex": "Male",
          "patient_weight": "",
          "patient_ethnicity": "",
          "patient_race": "",
          "patient_problems": [
            "Thrombosis/Thrombus",
            "Unspecified Vascular Problem",
            "Cardiovascular Dysfunction/Insufficiency"
          ]
        }
      ],
      "distributor_city": "",
      "date_report": "20260722",
      "initial_report_to_fda": "",
      "distributor_state": "",
      "event_key": "",
      "manufacturer_g1_country": "US",
      "manufacturer_contact_city": "Santa Clara",
      "mdr_report_key": "50301501",
      "removal_correction_number": "N/A",
      "number_devices_in_event": "",
      "date_manufacturer_received": "20260722",
      "manufacturer_name": "",
      "report_source_code": "Manufacturer report",
      "remedial_action": [
        "Other"
      ],
      "manufacturer_g1_zip_code": "95051",
      "report_to_manufacturer": "",
      "manufacturer_zip_code_ext": "",
      "manufacturer_g1_name": "INTUITIVE SURGICAL, INC",
      "adverse_event_flag": "Y",
      "distributor_address_1": "",
      "manufacturer_state": "",
      "distributor_address_2": "",
      "manufacturer_postal_code": "",
      "single_use_flag": "N",
      "manufacturer_country": "",
      "mdr_text": [
        {
          "mdr_text_key": "16001615048",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "0",
          "text": "Gobillot, T. A., Weinstein, G., Cao, A., Lee, J. J., Brody, R. M., Basu, D., O'Malley, B. W., Jr., Farwell, D. G., Cannady, S., Lin, A., Lukens, J., Gentile, M., Newman, J. G., Chalian, A. A., Sun, L., Lakshmipathy, D., Cohen, R. B., Rasskeh, C. H., & Rajasekaran, K. (2025). Outcomes of HPV+ oropharyngeal carcinoma of unknown primary following transoral robotic surgery. The Laryngoscope, 0, 19. https://doi.org/10.1002/lary.32449.No investigation could be performed as the article did not provide any specific information regarding the procedure date or da Vinci System identifiers. No image(s) and/or video clip(s) associated with this reported event were reviewed.Section A2: Patient Information Age: Reflects the study mean age of the patients in the robotic group. Section A3a- Patient Gender represents the majority of the patients in the robotic group. Section B7: The patient's medical history is updated per the majority of the patient's characteristics in the robotic group cohort.Section D: Due to the lack of specific information regarding the da Vinci system associated with the adverse event, a generic system material number was used.Section E - The event site is recorded based on the location of the first author's associated hospital. While the exact site is unknown, this designation is considered an appropriate substitution. Section E: Since this article was identified during a literature review by ISI, rather than reported by the site, the Corresponding Author is designated as the Initial reporter of the event."
        },
        {
          "mdr_text_key": "15501615047",
          "text_type_code": "Description of Event or Problem",
          "patient_sequence_number": "0",
          "text": "One patient experienced deep venous thrombosis and subsequent pulmonary embolus requiring placement of an inferior vena cava filter."
        }
      ],
      "number_patients_in_event": "",
      "distributor_name": "",
      "manufacturer_g1_address_1": "3410 Central Expressway",
      "distributor_zip_code": "",
      "manufacturer_contact_postal_code": "95051",
      "manufacturer_contact_exchange": "",
      "manufacturer_contact_pcountry": "",
      "suppl_dates_fda_received": ""
    }
  ]
}