  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-08",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "manufacturer_contact_zip_ext": "",
      "manufacturer_g1_address_2": "",
      "event_location": "",
      "report_to_fda": "",
      "manufacturer_contact_t_name": "",
      "manufacturer_contact_state": "CA",
      "manufacturer_link_flag": "Y",
      "manufacturer_contact_address_2": "",
      "manufacturer_g1_city": "SANTA CLARA",
      "manufacturer_contact_address_1": "3410 CENTRAL EXPRESSWAY",
      "manufacturer_contact_pcity": "40852321",
      "event_type": "Injury",
      "report_number": "2955842-2026-04862",
      "type_of_report": [
        "Initial submission"
      ],
      "product_problem_flag": "N",
      "date_received": "20260223",
      "manufacturer_address_2": "",
      "pma_pmn_number": "",
      "date_of_event": "20250306",
      "reprocessed_and_reused_flag": "N",
      "manufacturer_address_1": "",
      "exemption_number": "",
      "manufacturer_contact_zip_code": "95051",
      "reporter_occupation_code": "PHYSICIAN",
      "manufacturer_contact_plocal": "4085232100",
      "noe_summarized": "1",
      "manufacturer_contact_l_name": "NIELSON",
      "source_type": [
        "Other",
        "Literature",
        "Health Professional"
      ],
      "distributor_zip_code_ext": "",
      "manufacturer_g1_postal_code": "95051",
      "manufacturer_g1_state": "CA",
      "reporter_country_code": "US",
      "manufacturer_contact_area_code": "",
      "date_added": "20260223",
      "manufacturer_contact_f_name": "IZABEL",
      "previous_use_code": "R",
      "device": [
        {
          "device_event_key": "",
          "implant_flag": "",
          "date_removed_flag": "",
          "device_sequence_number": "475944",
          "implant_date_year": "",
          "date_removed_year": "",
          "serviced_by_3rd_party_flag": "",
          "date_received": "20260223",
          "brand_name": "DA VINCI",
          "generic_name": "DA VINCI",
          "manufacturer_d_name": "INTUITIVE SURGICAL, INC",
          "manufacturer_d_address_1": "3410 CENTRAL EXPRESSWAY",
          "manufacturer_d_address_2": "",
          "manufacturer_d_city": "SANTA CLARA",
          "manufacturer_d_state": "CA",
          "manufacturer_d_zip_code": "95051",
          "manufacturer_d_zip_code_ext": "",
          "manufacturer_d_country": "US",
          "manufacturer_d_postal_code": "95051",
          "device_operator": "HEALTH PROFESSIONAL",
          "model_number": "N/A",
          "catalog_number": "N/A",
          "lot_number": "N/A",
          "other_id_number": "",
          "device_availability": "No",
          "device_report_product_code": "NAY",
          "device_age_text": "",
          "device_evaluated_by_manufacturer": "N",
          "combination_product_flag": "N",
          "udi_di": "",
          "udi_public": "",
          "openfda": {
            "device_name": "System, Surgical, Computer Controlled Instrument",
            "medical_specialty_description": "Gastroenterology, Urology",
            "regulation_number": "876.1500",
            "device_class": "2"
          }
        }
      ],
      "product_problems": [
        "Adverse Event Without Identified Device or Use Problem"
      ],
      "reporter_state_code": "NY",
      "manufacturer_zip_code": "",
      "suppl_dates_mfr_received": "",
      "mfr_report_type": "Initial",
      "manufacturer_contact_country": "US",
      "date_changed": "20260501",
      "health_professional": "Y",
      "summary_report_flag": "N",
      "manufacturer_g1_zip_code_ext": "",
      "manufacturer_contact_extension": "",
      "manufacturer_city": "",
      "manufacturer_contact_phone_number": "",
      "patient": [
        {
          "patient_sequence_number": "1",
          "date_received": "20260223",
          "sequence_number_treatment": [
            "DA VINCI INSTRUMENTS AND ACCESSORIES"
          ],
          "sequence_number_outcome": [
            "Hospitalization",
            " R"
          ],
          "patient_age": "58 YR",
          "patient_sex": "Male",
          "patient_weight": "",
          "patient_ethnicity": "",
          "patient_race": "",
          "patient_problems": [
            "Hematoma",
            "Urinary Retention",
            "Bowel Perforation"
          ]
        }
      ],
      "distributor_city": "",
      "date_report": "20260128",
      "initial_report_to_fda": "",
      "distributor_state": "",
      "event_key": "",
      "manufacturer_g1_country": "US",
      "manufacturer_contact_city": "SANTA CLARA",
      "mdr_report_key": "24419386",
      "removal_correction_number": "N/A",
      "number_devices_in_event": "",
      "date_manufacturer_received": "20260128",
      "manufacturer_name": "",
      "report_source_code": "Manufacturer report",
      "remedial_action": [
        "Other"
      ],
      "manufacturer_g1_zip_code": "95051",
      "report_to_manufacturer": "",
      "manufacturer_zip_code_ext": "",
      "manufacturer_g1_name": "INTUITIVE SURGICAL, INC",
      "adverse_event_flag": "Y",
      "distributor_address_1": "",
      "manufacturer_state": "",
      "distributor_address_2": "",
      "manufacturer_postal_code": "",
      "single_use_flag": "N",
      "manufacturer_country": "",
      "mdr_text": [
        {
          "mdr_text_key": "393763440",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "0",
          "text": "SYSTEM LOGS REVIEW CANNOT BE PERFORMED AT THIS TIME BECAUSE THERE IS INSUFFICIENT EVENT DATE INFORMATION. NO INVESTIGATION COULD BE PERFORMED AS THE ARTICLE DID NOT PROVIDE ANY SPECIFIC INFORMATION REGARDING THE PROCEDURE DATE OR DA VINCI SYSTEM IDENTIFIERS. NO IMAGE(S) AND/OR VIDEO CLIP(S) ASSOCIATED WITH THIS REPORTED EVENT WERE INCLUDED IN THE ARTICLE. CITATION: TAGERMAN D, NESSEN M, LIMA DL, ET AL. ROBOTIC INGUINAL HERNIA REPAIR FOR THE NEW ROBOTIC SURGEON¿SAFETY AND EARLY OUTCOMES IN A LARGE ACADEMIC MEDICAL CENTER. J LAPAROENDOSC ADV SURG TECH. 2025;00(00). DOI:10.1089/LAP.2025.0051. SECTION A2: PATIENT AGE: REFLECTS THE STUDY MEAN YEARS OF 58. THE MAJORITY AGE RANGE WAS BETWEEN 43 AND 73 YRS. SECTION A3A- PATIENT GENDER IS SELECTED AS MALE. (88.2% OF THE PATIENTS ARE MALE). SECTION B7: THE PATIENT'S MEDICAL HISTORY IS UPDATED PER THE MAJORITY OF THE PATIENT'S CHARACTERISTICS IN THE ROBOTIC GROUP COHORT. SECTION D: THE PROCEDURES IN THE ARTICLE WERE PERFORMED ON BOTH DA VINCI XI AND SI SYSTEMS. THERE WAS NO DIFFERENTIATION PROVIDED REGARDING WHICH SYSTEM WAS USED PER PROCEDURE. SECTION E - THE EVENT SITE IS RECORDED BASED ON THE LOCATION OF THE FIRST AUTHOR'S ASSOCIATED HOSPITAL. WHILE THE EXACT SITE IS UNKNOWN, THIS DESIGNATION IS CONSIDERED AN APPROPRIATE SUBSTITUTION. SECTION E: SINCE THIS ARTICLE WAS IDENTIFIED DURING A LITERATURE REVIEW BY ISI, RATHER THAN REPORTED BY THE SITE, THE CORRESPONDING AUTHOR IS DESIGNATED AS THE INITIAL REPORTER OF THE EVENT. SECTION H10: RELATED MANUFACTURER REPORT NUMBER 2955842-2026-04766 IS A RELATED REPORT FOR THE PATIENT DEATH REPORTED IN THE SAME ARTICLE. ."
        },
        {
          "mdr_text_key": "393763441",
          "text_type_code": "Description of Event or Problem",
          "patient_sequence_number": "0",
          "text": "A REVIEW OF AN ARTICLE THAT EVALUATED THE OUTCOMES OF ROBOTIC INGUINAL HERNIA REPAIR (RIHR) IN A SINGLE-INSTITUTION STUDY COMPARING SURGEONS WITH VARYING ROBOTIC EXPERIENCE. THE STUDY ANALYZED 297 PATIENTS UNDERGOING ROBOTIC INGUINAL HERNIA REPAIR BETWEEN JULY 2016 AND SEPTEMBER 2021. THERE WERE 6 (2%) INTRAOPERATIVE COMPLICATIONS, INCLUDING 5 (1.7%) SEROSAL TEARS AND 1 (0.3%) FULL THICKNESS ENTEROTOMY. TWO CASES (0.7%) REPORTED CONVERSION TO OPEN PROCEDURES. ONE CASE INVOLVED A CHRONICALLY INCARCERATED SIGMOID COLON THAT COULD NOT BE REDUCED VIA A MINIMALLY INVASIVE APPROACH. THE SECOND CASE INVOLVED A RECURRENT HERNIA WITH SIGNIFICANT ADHESIONS AROUND A PRIOR PLUG REPAIR. ALL INTRAOPERATIVE INJURIES WERE CAUGHT AT THE TIME OF SURGERY AND DID NOT REQUIRE TAKEBACKS OR CAUSE SIGNIFICANT UNDUE HARM TO THE PATIENT. 28 PATIENTS (9.4%) PRESENTED TO THE ED WITH 30 DAYS OF THEIR SURGERIES WITH 20 PATIENTS (6.7%) RECEIVING ABDOMINAL IMAGING AND 13 PATIENTS (4.4%) BEING READMITTED. THERE WERE 8 TOTAL (2.7%) COMPLICATIONS INCLUDING 2 (0.7%) COMPLICATED SEROMAS, 4 HEMATOMAS (1.3%), AND 1 (0.3%) PATIENT WITH URINARY RETENTION. 30 DAY COMPLICATIONS WERE ALSO LARGELY MINOR WITH ONE PATIENT REQUIRING DRAINAGE OF A SEROMA. NO DEVICE MALFUNCTIONS WERE REPORTED, AND THE AUTHORS DID NOT REPORT ANY EVENTS CAUSED BY ANY ISI DEVICE. INTUITIVE SURGICAL INC, (ISI) CONTACTED THE AUTHOR WHO REPORTED THAT THERE WERE NO ISSUES SEEN OR RECORDED WITH THE DA VINCI SYSTEM DURING THE STUDY. THE SYSTEM ITSELF DID NOT CONTRIBUTE TO THE DEATH IN THE STUDY WHICH WAS RELATED TO THE PATIENTS CO MORBIDITY AND NOT THE SURGERY ITSELF."
        }
      ],
      "number_patients_in_event": "",
      "distributor_name": "",
      "manufacturer_g1_address_1": "3410 CENTRAL EXPRESSWAY",
      "distributor_zip_code": "",
      "manufacturer_contact_postal_code": "95051",
      "manufacturer_contact_exchange": "",
      "manufacturer_contact_pcountry": "",
      "suppl_dates_fda_received": ""
    }
  ]
}