  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-08",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "manufacturer_contact_zip_ext": "",
      "manufacturer_g1_address_2": "",
      "event_location": "",
      "report_to_fda": "",
      "manufacturer_contact_t_name": "",
      "manufacturer_contact_state": "CA",
      "manufacturer_link_flag": "Y",
      "manufacturer_contact_address_2": "",
      "manufacturer_g1_city": "SANTA CLARA",
      "manufacturer_contact_address_1": "3410 CENTRAL EXPRESSWAY",
      "manufacturer_contact_pcity": "40852321",
      "event_type": "Injury",
      "report_number": "2955842-2022-10194",
      "type_of_report": [
        "Initial submission"
      ],
      "product_problem_flag": "Y",
      "date_received": "20220207",
      "manufacturer_address_2": "",
      "pma_pmn_number": "K191280",
      "reprocessed_and_reused_flag": "N",
      "manufacturer_address_1": "",
      "exemption_number": "",
      "manufacturer_contact_zip_code": "",
      "reporter_occupation_code": "PHYSICIAN",
      "manufacturer_contact_plocal": "4085232100",
      "noe_summarized": "1",
      "manufacturer_contact_l_name": "NIELSON",
      "source_type": [
        "Other",
        "Health Professional"
      ],
      "distributor_zip_code_ext": "",
      "manufacturer_g1_postal_code": "",
      "manufacturer_g1_state": "CA",
      "reporter_country_code": "US",
      "manufacturer_contact_area_code": "408",
      "date_added": "20220208",
      "manufacturer_contact_f_name": "IZABEL",
      "previous_use_code": "I",
      "device": [
        {
          "device_event_key": "",
          "implant_flag": "",
          "date_removed_flag": "",
          "device_sequence_number": "757467",
          "implant_date_year": "",
          "date_removed_year": "",
          "serviced_by_3rd_party_flag": "",
          "date_received": "20220207",
          "brand_name": "DA VINCI ENERGY",
          "generic_name": "SYNCHROSEAL",
          "manufacturer_d_name": "INTUITIVE SURGICAL, INC",
          "manufacturer_d_address_1": "3410 CENTRAL EXPRESSWAY",
          "manufacturer_d_address_2": "",
          "manufacturer_d_city": "SANTA CLARA",
          "manufacturer_d_state": "CA",
          "manufacturer_d_zip_code": "",
          "manufacturer_d_zip_code_ext": "",
          "manufacturer_d_country": "",
          "manufacturer_d_postal_code": "",
          "device_operator": "HEALTH PROFESSIONAL",
          "model_number": "480440-05",
          "catalog_number": "480440",
          "lot_number": "NA",
          "other_id_number": "",
          "device_availability": "No",
          "device_report_product_code": "NAY",
          "device_age_text": "",
          "device_evaluated_by_manufacturer": "R",
          "combination_product_flag": "N",
          "udi_di": "",
          "udi_public": "",
          "openfda": {
            "device_name": "System, Surgical, Computer Controlled Instrument",
            "medical_specialty_description": "Gastroenterology, Urology",
            "regulation_number": "876.1500",
            "device_class": "2"
          }
        }
      ],
      "product_problems": [
        "Adverse Event Without Identified Device or Use Problem",
        "No Apparent Adverse Event",
        "Adverse Event Without Identified Device or Use Problem",
        "No Apparent Adverse Event"
      ],
      "reporter_state_code": "CT",
      "manufacturer_zip_code": "",
      "suppl_dates_mfr_received": "",
      "mfr_report_type": "Initial",
      "manufacturer_contact_country": "",
      "date_changed": "20250808",
      "health_professional": "Y",
      "summary_report_flag": "N",
      "manufacturer_g1_zip_code_ext": "",
      "manufacturer_contact_extension": "",
      "manufacturer_city": "",
      "manufacturer_contact_phone_number": "4085",
      "patient": [
        {
          "patient_sequence_number": "1",
          "date_received": "20220207",
          "sequence_number_treatment": [
            "DA VINCI INSTRUMENTS AND ACCESSORIES"
          ],
          "sequence_number_outcome": [
            ""
          ],
          "patient_age": "",
          "patient_sex": "Unknown",
          "patient_weight": "",
          "patient_ethnicity": "",
          "patient_race": "",
          "patient_problems": [
            "Hematoma",
            "Hemorrhage/Blood Loss/Bleeding",
            "Thromboembolism",
            "Hematoma",
            "Hemorrhage/Blood Loss/Bleeding",
            "Thromboembolism"
          ]
        }
      ],
      "distributor_city": "",
      "date_report": "20220113",
      "initial_report_to_fda": "",
      "distributor_state": "",
      "event_key": "",
      "manufacturer_g1_country": "",
      "manufacturer_contact_city": "SANTA CLARA",
      "mdr_report_key": "13477283",
      "removal_correction_number": "N/A",
      "number_devices_in_event": "",
      "date_manufacturer_received": "20220113",
      "manufacturer_name": "",
      "report_source_code": "Manufacturer report",
      "remedial_action": [
        "Other"
      ],
      "manufacturer_g1_zip_code": "",
      "report_to_manufacturer": "",
      "manufacturer_zip_code_ext": "",
      "manufacturer_g1_name": "INTUITIVE SURGICAL, INC",
      "adverse_event_flag": "Y",
      "distributor_address_1": "",
      "manufacturer_state": "",
      "distributor_address_2": "",
      "manufacturer_postal_code": "",
      "single_use_flag": "Y",
      "manufacturer_country": "",
      "mdr_text": [
        {
          "mdr_text_key": "289460411",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "0",
          "text": "BASED ON THE CURRENT INFORMATION PROVIDED, THE ROOT CAUSE OF THE REPORTED POST-OPERATIVE COMPLICATION CANNOT BE DETERMINED OR IS UNKNOWN. THE SYNCHROSEAL INSTRUMENT IS UNAVAILABLE FOR EVALUATION. IF ADDITIONAL INFORMATION IS RECEIVED, A FOLLOW-UP MDR WILL BE SUBMITTED. NO IMAGE OR VIDEO CLIP FOR THE REPORTED EVENT WAS SUBMITTED FOR REVIEW. A SYSTEM LOG REVIEW WAS NOT PERFORMED SINCE THERE IS INSUFFICIENT OR UNCONFIRMED EVENT INFORMATION. THERE IS NO DATE OF EVENT PROVIDED. THIS COMPLAINT IS BEING REPORTED DUE TO THE FOLLOWING CONCLUSION: AFTER A DA VINCI-ASSISTED SLEEVE GASTRECTOMY SURGICAL PROCEDURE, THE PATIENT EXPERIENCED POST-OPERATIVE BLEEDING. THE SURGEON ALLEGED THAT THE SYNCHROSEAL INSTRUMENT WAS A CONTRIBUTING FACTOR TO THE POST-OPERATIVE COMPLICATION. THE SURGEON CONFIRMED THAT THERE WAS NO SURGICAL INTERVENTION OR BLOOD TRANSFUSIONS RENDERED TO THE PATIENT. HOWEVER, THE PATIENT WAS HOSPITALIZED FOR IV FLUIDS, BLOOD WORK, CT SCAN AND OBSERVATION. THE CAUSE OF THE POST-OPERATIVE BLEEDING IS UNKNOWN."
        },
        {
          "mdr_text_key": "289460412",
          "text_type_code": "Description of Event or Problem",
          "patient_sequence_number": "0",
          "text": "IT WAS REPORTED THAT AFTER A DA VINCI-ASSISTED SLEEVE GASTRECTOMY SURGICAL PROCEDURE, THE PATIENT EXPERIENCED POST-OPERATIVE BLEEDING AND RETURNED TO THE FACILITY FOR TREATMENT. INTUITIVE SURGICAL, INC. (ISI) CONTACTED THE SURGEON AND OBTAINED THE FOLLOWING INFORMATION. ON AN UNSPECIFIED POSTOPERATIVE DAY, THE PATIENT PRESENTED WITH HYPOTENSIVE SYMPTOMS. A CT SCAN REVEALED A HEMATOMA ON THE GREATER CURVE AREA. THE PATIENT HAD DEEP VEIN THROMBOSIS (DVT) AND A PULMONARY EMBOLISM. THE SURGEON STATED HE BELIEVES THE POST-OPERATIVE BLEEDING WAS FROM THE RIGHT GASTROEPIPLOIC OR THE SHORT GASTRIC VESSEL, AND WAS RELATED TO THE SYNCHROSEAL INSTRUMENT USED ON THOSE VESSELS. THE SURGEON DOES NOT SKELETONIZE THE VESSELS BEFORE SEALING. HE STATED HE DOES NOT LIKE HOW THE SYNCHROSEAL CUTS, AND HE HAS TO CUT THE VESSEL MORE THAN ONCE. THE SURGEON HAS NEVER HAD POST-OPERATIVE BLEEDING IN THE PAST, AND WILL REVERT TO USING THE VESSEL SEALER EXTEND INSTRUMENT. THE SURGEON CONFIRMED THAT THERE WAS NO SURGICAL INTERVENTION OR BLOOD TRANSFUSIONS RENDERED TO THE PATIENT. HOWEVER, THE PATIENT WAS HOSPITALIZED FOR IV FLUIDS, BLOOD WORK, CT SCAN AND OBSERVATION."
        }
      ],
      "number_patients_in_event": "",
      "distributor_name": "",
      "manufacturer_g1_address_1": "3410 CENTRAL EXPRESSWAY",
      "distributor_zip_code": "",
      "manufacturer_contact_postal_code": "",
      "manufacturer_contact_exchange": "408",
      "manufacturer_contact_pcountry": "",
      "suppl_dates_fda_received": ""
    }
  ]
}