  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-08",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "manufacturer_contact_zip_ext": "",
      "manufacturer_g1_address_2": "",
      "event_location": "",
      "report_to_fda": "",
      "manufacturer_contact_t_name": "",
      "manufacturer_contact_state": "CA",
      "manufacturer_link_flag": "Y",
      "manufacturer_contact_address_2": "",
      "manufacturer_g1_city": "SANTA CLARA",
      "manufacturer_contact_address_1": "3410 CENTRAL EXPRESSWAY",
      "manufacturer_contact_pcity": "40852321",
      "event_type": "Injury",
      "report_number": "2955842-2022-10106",
      "type_of_report": [
        "Initial submission",
        "Followup"
      ],
      "product_problem_flag": "Y",
      "date_received": "20220121",
      "manufacturer_address_2": "",
      "pma_pmn_number": "K143132",
      "date_of_event": "20211221",
      "reprocessed_and_reused_flag": "N",
      "manufacturer_address_1": "",
      "exemption_number": "",
      "manufacturer_contact_zip_code": "",
      "reporter_occupation_code": "NURSE",
      "manufacturer_contact_plocal": "4085232100",
      "noe_summarized": "1",
      "manufacturer_contact_l_name": "NIELSON",
      "source_type": [
        "Other",
        "Foreign",
        "Health Professional"
      ],
      "distributor_zip_code_ext": "",
      "manufacturer_g1_postal_code": "",
      "manufacturer_g1_state": "CA",
      "reporter_country_code": "KS",
      "manufacturer_contact_area_code": "408",
      "date_added": "20220121",
      "manufacturer_contact_f_name": "IZABEL",
      "device_date_of_manufacturer": "20210921",
      "previous_use_code": "I",
      "device": [
        {
          "device_event_key": "",
          "implant_flag": "",
          "date_removed_flag": "",
          "device_sequence_number": "806287",
          "implant_date_year": "",
          "date_removed_year": "",
          "serviced_by_3rd_party_flag": "",
          "date_received": "20220121",
          "brand_name": "DA VINCI",
          "generic_name": "HARMONIC ACE",
          "manufacturer_d_name": "INTUITIVE SURGICAL, INC",
          "manufacturer_d_address_1": "3410 CENTRAL EXPRESSWAY",
          "manufacturer_d_address_2": "",
          "manufacturer_d_city": "SANTA CLARA",
          "manufacturer_d_state": "CA",
          "manufacturer_d_zip_code": "",
          "manufacturer_d_zip_code_ext": "",
          "manufacturer_d_country": "",
          "manufacturer_d_postal_code": "",
          "device_operator": "HEALTH PROFESSIONAL",
          "model_number": "480275-08",
          "catalog_number": "480275",
          "lot_number": "L90210922 0086",
          "other_id_number": "",
          "device_availability": "Device was returned to manufacturer",
          "date_returned_to_manufacturer": "20220111",
          "device_report_product_code": "NAY",
          "device_age_text": "DA",
          "device_evaluated_by_manufacturer": "Y",
          "combination_product_flag": "N",
          "udi_di": "10886874112738",
          "udi_public": "(01)10886874112738(17)230930(10)L90210922",
          "openfda": {
            "device_name": "System, Surgical, Computer Controlled Instrument",
            "medical_specialty_description": "Gastroenterology, Urology",
            "regulation_number": "876.1500",
            "device_class": "2"
          }
        }
      ],
      "product_problems": [
        "Thermal Decomposition of Device",
        "Thermal Decomposition of Device"
      ],
      "reporter_state_code": "",
      "manufacturer_zip_code": "",
      "suppl_dates_mfr_received": "12/23/2021",
      "mfr_report_type": "Initial",
      "manufacturer_contact_country": "",
      "date_changed": "20250729",
      "health_professional": "Y",
      "summary_report_flag": "N",
      "manufacturer_g1_zip_code_ext": "",
      "manufacturer_contact_extension": "",
      "manufacturer_city": "",
      "manufacturer_contact_phone_number": "4085",
      "patient": [
        {
          "patient_sequence_number": "1",
          "date_received": "20220121",
          "sequence_number_treatment": [
            "DA VINCI INSTRUMENTS AND ACCESSORIES"
          ],
          "sequence_number_outcome": [
            ""
          ],
          "patient_age": "",
          "patient_sex": "Unknown",
          "patient_weight": "",
          "patient_ethnicity": "",
          "patient_race": "",
          "patient_problems": [
            "Foreign Body In Patient",
            "Insufficient Information",
            "Foreign Body In Patient",
            "Insufficient Information"
          ]
        }
      ],
      "distributor_city": "",
      "date_report": "20211223",
      "initial_report_to_fda": "No",
      "distributor_state": "",
      "event_key": "",
      "manufacturer_g1_country": "",
      "manufacturer_contact_city": "SANTA CLARA",
      "mdr_report_key": "13314710",
      "removal_correction_number": "N/A",
      "number_devices_in_event": "",
      "date_manufacturer_received": "20211223",
      "manufacturer_name": "",
      "report_source_code": "Manufacturer report",
      "remedial_action": [
        "Other"
      ],
      "manufacturer_g1_zip_code": "",
      "report_to_manufacturer": "",
      "manufacturer_zip_code_ext": "",
      "manufacturer_g1_name": "INTUITIVE SURGICAL, INC",
      "adverse_event_flag": "Y",
      "distributor_address_1": "",
      "manufacturer_state": "",
      "distributor_address_2": "",
      "manufacturer_postal_code": "",
      "single_use_flag": "Y",
      "manufacturer_country": "",
      "mdr_text": [
        {
          "mdr_text_key": "284182348",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "0",
          "text": "INTUITIVE SURGICAL, INC. (ISI) RECEIVED THE HARMONIC ACE INSTRUMENT INVOLVED WITH THIS COMPLAINT AND COMPLETED THE DEVICE EVALUATION. FAILURE ANALYSIS (FA) INVESTIGATIONS REPLICATED AND CONFIRMED THE CUSTOMER REPORTED COMPLAINT \"TEFLON PAD WAS MELTING AND FRAGMENTS WERE FALLING DOWN\". FAILURE ANALYSIS FOUND THE PRIMARY FAILURE OF TEFLON PAD DAMAGE TO BE RELATED TO THE CUSTOMER COMPLAINT. VISUAL INSPECTION OF THE INSTRUMENT FOUND THE TEFLON PAD EXHIBITED THERMAL DAMAGE NEAR THE BASE OF THE CLAMP ARM. A PIECE MEASURING ROUGHLY 0.027\" X 0.034\" WAS MISSING FROM THE TEFLON PAD AND WAS NOT RETURNED WITH THE INSTRUMENT. NO BLADE DAMAGE WAS OBSERVED. THE ROOT CAUSE FOR THE TEFLON PAD DAMAGE IS ATTRIBUTED TO MISHANDLING/MISUSE. A REVIEW OF THE INSTRUMENT LOG FOR THE HARMONIC ACE (PART # 480275-08/LOT# L902109220086) ASSOCIATED WITH THIS EVENT HAS BEEN PERFORMED. PER LOGS, THE INSTRUMENT WAS LAST USED ON (B)(6) 2021, ON SYSTEM SK3594. THIS IS A SINGLE-USE INSTRUMENT. IN ADDITION, A REVIEW OF THE SITE'S COMPLAINT HISTORY IDENTIFIED NO OTHER COMPLAINTS RELATED TO THE INSTRUMENT AND OR THIS EVENT. NO IMAGE OR VIDEO CLIP FOR THE REPORTED EVENT WAS SUBMITTED TO ISI FOR REVIEW. BASED ON THE INFORMATION PROVIDED AT THIS TIME, THIS COMPLAINT IS BEING CLASSIFIED AS A REPORTABLE ADVERSE EVENT DUE TO THE FOLLOWING CONCLUSION: THE HARMONIC ACE INSTRUMENT WAS FOUND TO HAVE THE TEFLON PAD MELTED. THE FRAGMENTS FELL INSIDE THE PATIENT AND WERE NOT RETRIEVED. FAILURE ANALYSIS CONFIRMED THE ISSUE AND THE ROOT CAUSE WAS ATTRIBUTED TO USER MISHANDLING OR MISUSE. PER FA INVESTIGATION FINDINGS, THERE IS NO EVIDENCE THAT A DEVICE MALFUNCTION CAUSED/CONTRIBUTED TO THE ALLEGED EVENT."
        },
        {
          "mdr_text_key": "284182349",
          "text_type_code": "Description of Event or Problem",
          "patient_sequence_number": "0",
          "text": "IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED THYROIDECTOMY SURGICAL PROCEDURE, THE HARMONIC ACE INSTRUMENT WAS FOUND TO HAVE THE TEFLON PAD MELTED, AND FRAGMENTS WERE FALLING INSIDE THE PATIENT. THE FRAGMENTS WERE NOT RETRIEVED. THE CUSTOMER REMOVED THE INSTRUMENT AND USED A BACKUP INSTRUMENT TO COMPLETE THE PROCEDURE. INTUITIVE SURGICAL, INC. (ISI) FOLLOWED UP WITH THE INITIAL REPORTER AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: THE INSTRUMENT WAS INSPECTED PRIOR TO USE WITH NO DAMAGE OBSERVED. THE TEFLON PAD MELTED LIKE POWDER AS SOON AS THE CUSTOMER STARTED TO USE THE INSTRUMENT. THE FRAGMENTS WERE NOT RETRIEVED AS THEY WERE NOTED TO BE \"LIKE POWDER.\" IT WAS UNKNOWN WHAT CAUSED THE MELTING TO OCCUR AS THE INSTRUMENT DID NOT COLLIDE WITH ANY HARD MATERIALS OR OTHER INSTRUMENTS, AND THE CUSTOMER CONFIRMED THAT ARCING WAS NOT OBSERVED. THE THYROID TISSUE DID NOT APPEAR TO BE TOO THICK. THE SURGEON DID NOT NOTICE ANY ISSUES WITH THE FUNCTIONALITY OF THE INSTRUMENT. NO POST-OPERATIVE TESTS LIKE AN X-RAY OR ULTRASOUND WERE PERFORMED, AND NO ADDITIONAL SURGICAL PROCEDURE WAS PERFORMED. THE PATIENT HAS NOT RETURNED TO THE HOSPITAL DUE TO EXPERIENCING ANY POST-SURGICAL COMPLICATIONS RELATED TO RETAINING A FOREIGN OBJECT. THE DA VINCI 8 MM HARMONIC ACE CURVED SHEARS IS A SINGLE-USE, STERILE INSTRUMENT USED TO DELIVER ULTRASONIC ENERGY TO ENABLE TRANSECTION AND COAGULATION OF TISSUE. IT IS DESIGNED TO BE USED IN CONJUNCTION WITH A COMPATIBLE DA VINCI SURGICAL SYSTEM AND A COMPATIBLE ETHICON ENDO-SURGERY GENERATOR AND HAND PIECE."
        },
        {
          "mdr_text_key": "334853702",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "0",
          "text": "BASED ON A RE-EVALUATION OF THE COMPLAINT INFORMATION, THIS COMPLAINT HAS BEEN RECLASSIFIED AS AN ADVERSE EVENT AND PRODUCT PROBLEM RATHER THAN JUST A ADVERSE EVENT, AS PREVIOUSLY REPORTED. CORRECTED INFORMATION CAN BE FOUND THE FOLLOWING FIELD: B1, H6 B1 UPDATED FROM \"ADVERSE EVENT\" TO \"ADVERSE EVENT AND PRODUCT PROBLEM\"."
        },
        {
          "mdr_text_key": "334853703",
          "text_type_code": "Description of Event or Problem",
          "patient_sequence_number": "0",
          "text": "REFER TO H10/H11 FOR FOLLOW-UP INFORMATION."
        }
      ],
      "number_patients_in_event": "",
      "distributor_name": "",
      "manufacturer_g1_address_1": "3410 CENTRAL EXPRESSWAY",
      "distributor_zip_code": "",
      "manufacturer_contact_postal_code": "",
      "manufacturer_contact_exchange": "408",
      "manufacturer_contact_pcountry": "",
      "suppl_dates_fda_received": "05/24/2023"
    }
  ]
}