  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-09-08",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "manufacturer_contact_zip_ext": "",
      "manufacturer_g1_address_2": "",
      "event_location": "",
      "report_to_fda": "",
      "manufacturer_contact_t_name": "",
      "manufacturer_contact_state": "",
      "manufacturer_link_flag": "Y",
      "manufacturer_contact_address_2": "",
      "manufacturer_g1_city": "",
      "manufacturer_contact_address_1": "",
      "manufacturer_contact_pcity": "",
      "event_type": "Injury",
      "report_number": "2955842-2008-01144",
      "type_of_report": [
        "Initial submission"
      ],
      "product_problem_flag": "N",
      "date_received": "20080715",
      "manufacturer_address_2": "",
      "pma_pmn_number": "",
      "date_of_event": "20080616",
      "reprocessed_and_reused_flag": "N",
      "manufacturer_address_1": "",
      "exemption_number": "",
      "manufacturer_contact_zip_code": "",
      "reporter_occupation_code": "OTHER",
      "manufacturer_contact_plocal": "",
      "noe_summarized": "1",
      "manufacturer_contact_l_name": "",
      "source_type": [
        "Company representation"
      ],
      "distributor_zip_code_ext": "",
      "manufacturer_g1_postal_code": "",
      "manufacturer_g1_state": "",
      "reporter_country_code": "US",
      "manufacturer_contact_area_code": "",
      "date_added": "20080723",
      "manufacturer_contact_f_name": "",
      "previous_use_code": "",
      "device": [
        {
          "device_event_key": "",
          "implant_flag": "",
          "date_removed_flag": "",
          "device_sequence_number": "1",
          "date_received": "20080715",
          "brand_name": "DA VINCI S SURGICAL SYSTEM",
          "generic_name": "ENDOSCOPIC INSTRUMENT CONTROL SYSTEM",
          "manufacturer_d_name": "INTUITIVE SURGICAL, INC.",
          "manufacturer_d_address_1": "",
          "manufacturer_d_address_2": "",
          "manufacturer_d_city": "SUNNYVALE",
          "manufacturer_d_state": "CA",
          "manufacturer_d_zip_code": "",
          "manufacturer_d_zip_code_ext": "",
          "manufacturer_d_country": "US",
          "manufacturer_d_postal_code": "",
          "device_operator": "HEALTH PROFESSIONAL",
          "model_number": "IS2000 A5.1P4",
          "catalog_number": "",
          "lot_number": "",
          "other_id_number": "",
          "device_availability": "Yes",
          "device_report_product_code": "NAY",
          "device_age_text": "",
          "device_evaluated_by_manufacturer": "Y",
          "combination_product_flag": "N",
          "udi_di": "",
          "udi_public": "",
          "openfda": {
            "registration_number": [
              "2955842"
            ],
            "fei_number": [
              "3008615487"
            ],
            "device_name": "System, Surgical, Computer Controlled Instrument",
            "medical_specialty_description": "Gastroenterology, Urology",
            "regulation_number": "876.1500",
            "device_class": "2"
          }
        }
      ],
      "product_problems": [
        "Unintended System Motion"
      ],
      "reporter_state_code": "CA",
      "manufacturer_zip_code": "",
      "suppl_dates_mfr_received": "",
      "mfr_report_type": "Thirty-Day",
      "manufacturer_contact_country": "",
      "date_changed": "20250725",
      "health_professional": "",
      "summary_report_flag": "N",
      "manufacturer_g1_zip_code_ext": "",
      "manufacturer_contact_extension": "",
      "manufacturer_city": "",
      "manufacturer_contact_phone_number": "",
      "patient": [
        {
          "patient_sequence_number": "1",
          "date_received": "20080715",
          "sequence_number_treatment": [
            "DA VINCI S INSTRUMENT",
            " ACCESSORIES"
          ],
          "sequence_number_outcome": [
            "Life Threatening",
            " R"
          ],
          "patient_age": "",
          "patient_sex": "",
          "patient_weight": "",
          "patient_ethnicity": "",
          "patient_race": "",
          "patient_problems": [
            "Tissue Damage",
            "Improved patient condition",
            "Therapy/non-surgical treatment, additional",
            "Surgical procedure, additional"
          ]
        }
      ],
      "distributor_city": "",
      "date_report": "20080715",
      "initial_report_to_fda": "",
      "distributor_state": "",
      "event_key": "",
      "manufacturer_g1_country": "",
      "manufacturer_contact_city": "",
      "mdr_report_key": "1077464",
      "removal_correction_number": "",
      "number_devices_in_event": "",
      "date_manufacturer_received": "20080617",
      "manufacturer_name": "",
      "report_source_code": "Manufacturer report",
      "remedial_action": [
        ""
      ],
      "manufacturer_g1_zip_code": "",
      "report_to_manufacturer": "",
      "manufacturer_zip_code_ext": "",
      "manufacturer_g1_name": "",
      "adverse_event_flag": "Y",
      "distributor_address_1": "",
      "manufacturer_state": "",
      "distributor_address_2": "",
      "manufacturer_postal_code": "",
      "single_use_flag": "",
      "manufacturer_country": "",
      "mdr_text": [
        {
          "mdr_text_key": "21994285",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "1",
          "text": "THE INVESTIGATION CONDUCTED BY AN ISU FIELD SERVICE ENGINEER FOUND THE SYSTEM TO SUCCESSFULLY COMPLETED ALL VERIFICATION TESTS AND TO FUNCTION AS DESIGNED. NO SYSTEM ERRORS RELATED TO THE CAUSE OF THIS EVENT WERE FOUND. ADDITIONAL INVESTIGATIONS CONDUCTED BY CLINICAL AND SOFTWARE ENGINEERING WERE INCONCLUSIVE AS A ROOT CAUSE COULD NOT BE DETERMINED BASED ON THE EVENT DESCRIPTIONS REPORTED BY SEVERAL EYE WITNESSES AND THE REVIEW OF THE SYSTEM'S EVENT LOGS. THE LOGS DID SHOW THAT NEAR THE TIME OF THE EVENT, THE ARM (HOLDING THE ENDOWRIST STABILIZER INSTRUMENT) WAS \"UNLOCKED\", INDICATING THAT THE INSTRUMENT WAS READY FOR SURGEON CONTROL. THE PARTICULAR LOG USED TO DETERMINE IF THE INSTRUMENT WAS CONTROLLED AND ACTIVELY IN USE AT THE TIME OF THE EVENT HAD NOT RETAINED THE INFORMATION AS EACH LOG RECORDS INFO IN A CIRCULAR BUFFER OF LIMITED LENGTHS. THIS MEANS A FINITE NUMBER OF THE MOST RECENT EVENTS ARE RECORDED IN THE LOG. THE HOSP HAS CONTINUED TO USE THE DA VINCI S SYSTEM TO PERFORM SURGERY ON PATIENTS. AS OF 2008, NO ADVERSE EVENTS OR SIMILAR INSTANCES OF THIS EVENT HAVE BEEN REPORTED."
        },
        {
          "mdr_text_key": "22123006",
          "text_type_code": "Description of Event or Problem",
          "patient_sequence_number": "1",
          "text": "IT WAS REPORTED THAT DURING A DA VINCI S BEATING HEART DOUBLE VESSEL CORONARY ARTERY BYPASS GRAFT PROCEDURE AT THE HOSPITAL, THERE WAS AN UNEXPLAINED MOVEMENT ON THE SYSTEM ARM WHICH HAD THE ENDOWRIST STABILIZER INSTRUMENT ATTACHED TO IT. THE UNEXPECTED MOVEMENT CAUSED THE FEET AT THE DISTAL END OF THE ENDOWRIST STABILIZER INSTRUMENT TO TIP DOWNWARD RESULTING IN DAMAGE TO THE MYOCARDIUM OF THE PATIENT'S LEFT VENTRICLE. THE SURGICAL TEAM IMMEDIATELY CONVERTED TO AN OPEN STERNOTOMY TO SUCCESSFULLY REPAIR THE DAMAGED VENTRICLE WITH A SINGLE MEDTRONIC U-CLIP S50. THE PATIENT WAS REPORTED AS RECOVERING WELL WITH NO POST-OPERATIVE COMPLICATIONS."
        }
      ],
      "number_patients_in_event": "",
      "distributor_name": "",
      "manufacturer_g1_address_1": "",
      "distributor_zip_code": "",
      "manufacturer_contact_postal_code": "",
      "manufacturer_contact_exchange": "",
      "manufacturer_contact_pcountry": "",
      "suppl_dates_fda_received": ""
    }
  ]
}