{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-07-07",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 419076
    }
  },
  "results": [
    {
      "manufacturer_contact_zip_ext": "",
      "manufacturer_g1_address_2": "",
      "event_location": "",
      "report_to_fda": "N",
      "manufacturer_contact_t_name": "",
      "manufacturer_contact_state": "",
      "manufacturer_link_flag": "Y",
      "manufacturer_contact_address_2": "",
      "manufacturer_g1_city": "",
      "manufacturer_contact_address_1": "",
      "manufacturer_contact_pcity": "",
      "event_type": "Injury",
      "report_number": "3003681312-2007-00026",
      "type_of_report": [
        "Initial submission"
      ],
      "product_problem_flag": "N",
      "date_received": "20070514",
      "manufacturer_address_2": "",
      "pma_pmn_number": "P930038",
      "date_of_event": "20070417",
      "reprocessed_and_reused_flag": "N",
      "manufacturer_address_1": "",
      "exemption_number": "",
      "manufacturer_contact_zip_code": "",
      "reporter_occupation_code": "RISK MANAGER",
      "manufacturer_contact_plocal": "",
      "noe_summarized": "1",
      "manufacturer_contact_l_name": "",
      "source_type": [
        "Health Professional",
        "User facility",
        "Company representation"
      ],
      "distributor_zip_code_ext": "",
      "manufacturer_g1_postal_code": "",
      "manufacturer_g1_state": "",
      "reporter_country_code": "US",
      "manufacturer_contact_area_code": "",
      "date_added": "20080221",
      "manufacturer_contact_f_name": "",
      "previous_use_code": "",
      "device": [
        {
          "device_event_key": "",
          "implant_flag": "",
          "date_removed_flag": "",
          "device_sequence_number": "1",
          "date_received": "20070514",
          "brand_name": "6F ANGIO-SEAL VASCULAR CLOSURE DEVICE VIP",
          "generic_name": "ANGIO-SEAL VIP",
          "manufacturer_d_name": "ST. JUDE MEDICAL, PUERTO RICO, B.V.",
          "manufacturer_d_address_1": "*",
          "manufacturer_d_address_2": "",
          "manufacturer_d_city": "CAGUAS",
          "manufacturer_d_state": "PR",
          "manufacturer_d_zip_code": "*",
          "manufacturer_d_zip_code_ext": "",
          "manufacturer_d_country": "US",
          "manufacturer_d_postal_code": "*",
          "device_operator": "HEALTH PROFESSIONAL",
          "expiration_date_of_device": "20080201",
          "model_number": "NA",
          "catalog_number": "610130",
          "lot_number": "1877",
          "other_id_number": "NA",
          "device_availability": "No",
          "device_report_product_code": "MGB",
          "device_age_text": "",
          "device_evaluated_by_manufacturer": "R",
          "combination_product_flag": "N",
          "udi_di": "",
          "udi_public": "",
          "openfda": {
            "device_name": "Device, Hemostasis, Vascular",
            "medical_specialty_description": "Unknown",
            "regulation_number": "",
            "device_class": "3"
          }
        }
      ],
      "product_problems": [
        "Device, removal of (non-implant)",
        "Malposition of Device"
      ],
      "reporter_state_code": "FL",
      "manufacturer_zip_code": "",
      "suppl_dates_mfr_received": "",
      "mfr_report_type": "Thirty-Day",
      "manufacturer_contact_country": "",
      "date_changed": "20250728",
      "health_professional": "",
      "summary_report_flag": "N",
      "manufacturer_g1_zip_code_ext": "",
      "manufacturer_contact_extension": "",
      "manufacturer_city": "",
      "manufacturer_contact_phone_number": "",
      "patient": [
        {
          "patient_sequence_number": "1",
          "date_received": "20070514",
          "sequence_number_treatment": [
            "DIOVAN HCTZ, 320/25 P.O.",
            " PLAVIX, 75 MG P.O",
            " COMBIVENT INHALER 2 PUFFS 4 TIMES A DAY",
            " ZOCAR, 20 NIGHTLY",
            " LOPRESSOR, 25 B.I.D.",
            " NORVASC, 10 DAILY",
            " ASPIRIN, 81 DAILY"
          ],
          "sequence_number_outcome": [
            "Required Intervention"
          ],
          "patient_age": "60 YR",
          "patient_sex": "",
          "patient_weight": "",
          "patient_ethnicity": "",
          "patient_race": "",
          "patient_problems": [
            "Occlusion",
            "Pain",
            "Improved patient condition",
            "Surgical procedure",
            "Numbness",
            "Loss Of Pulse"
          ]
        }
      ],
      "distributor_city": "",
      "date_report": "20070423",
      "initial_report_to_fda": "",
      "distributor_state": "",
      "event_key": "",
      "manufacturer_g1_country": "",
      "manufacturer_contact_city": "",
      "mdr_report_key": "1000020",
      "removal_correction_number": "",
      "number_devices_in_event": "",
      "manufacturer_name": "",
      "report_source_code": "Manufacturer report",
      "remedial_action": [
        ""
      ],
      "manufacturer_g1_zip_code": "",
      "report_to_manufacturer": "",
      "manufacturer_zip_code_ext": "",
      "manufacturer_g1_name": "",
      "adverse_event_flag": "Y",
      "distributor_address_1": "",
      "manufacturer_state": "",
      "distributor_address_2": "",
      "manufacturer_postal_code": "",
      "single_use_flag": "",
      "manufacturer_country": "",
      "mdr_text": [
        {
          "mdr_text_key": "15628744",
          "text_type_code": "Description of Event or Problem",
          "patient_sequence_number": "1",
          "text": "IT WAS REPORTED FOLLOWING A PERCUTANEOUS CORONARY INTERVENTION (PCI) A 6F ANGIO-SEAL VIP WAS DEPLOYED IN THE RIGHT FEMORAL ARTERY. A PRE-DEPLOYMENT FEMORAL ANGIOGRAM REVEALED SIGNIFICANT ATHEROSCLEROTIC DISEASE, BUT AN INABILITY TO COMPRESS THE ACCESS SITE ON A PRIOR PROCEDURE PROMPTED THE ANGIO-SEAL USE. HEMOSTASIS WAS NOT ACHIEVED AND MANUAL COMPRESSION WAS APPLIED. THE PT WAS TRASNFERRED TO ANOTHER HOSP FOR RECOVERY WHERE THE PT EXPERIENCED PAIN IN THE RIGHT FOOT AND EVAL REVEALED NO DOPPLERABLE PULSE IN THE RIGHT LOWER LEG. AN ARTERIAL DUPLEX SCAN REVEALED MODERATE TO SEVERE CALCIFIED PLAQUE THROUGHOUT THE LEG WITH AN INCREASED VELOCITY THAT SUGGESTED A SIGNIFICANT STENOSIS AT THE SUPERFICIAL FEMORAL ARTERY (SFA). A CT SURGICAL EXPLORATION REVEALED THE COLLAGEN PLUG FROM THE ANGIO-SEAL WAS INTRAVASCULAR AND WAS OCCLUDING THE VESSEL. THE ANGIO-SEAL WAS REMOVED AND A VEIN PATCH RESTORED FLOW TO THE LOWER EXTREMITY. THE PT WAS FEELING MUCH IMPROVED WITH SLIGHT NUMBNESS IN THE FOOT."
        },
        {
          "mdr_text_key": "15990485",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "1",
          "text": "NO PRODUCT WAS RETURNED FOR EVAL. REVIEW OF THE DEVICE HISTORY RECORD CONFIRMED THIS LOT MET MFG REQUIREMENTS PRIOR TO SHIPMENT. BASED ON THE INFO RECEIVED, THE CAUSE FOR THE REPORTED EVENT COULD NOT BE CONCLUSIVELY DETERMINED. THE ANGIO-SEAL DEVICE INSTRUCTION FOR USE (IFU) STATE THAT BLEEDING OR HEMATOMA AT THE PUNCTURE SITE IS A POSSIBLE RISK OR SITUATION THAT MAY BE ASSOCIATED WITH THE USE OF THE DEVICE OR VASCULAR ACCESS PROCEDURES. IF THIS SHOULD OCCUR, THE IFU INSTRUCT THE USER TO APPLY DIGITAL OR MANUAL PRESSURE TO THE PUNCTURE SITE. IF NECESSARY, MONITOR PEDAL PULSES. THE ANGIO-SEAL IFU STATES THAT IF COLLAGEN DEPOSTION INTO THE ARTERY IS SUSPECTED, THE DIAGNOSIS CAN BE CONFIRMED BY DUPLEX ULTRASOUND. TREATMENT OF THIS MAY INCLUDE THROMBOLYSIS, PERCUTANEOUS THROMBECTOMY, OR SURGICAL INTERVENTION. THE ANGIO-SEAL IFU INSTRUCTS THE USER ONCE A FULL REAR LOCK POSITION HAS BEEN ACHIEVED, AND THE DEVICE IS BEING DEPLOYED, TO NOT RE-INSERT THE DEVICE.  RE-INSERTION OF THE DEVICE AFTER PARTIAL DEPLOYMENT COULD CAUSE COLLAGEN TO BE DEPOSITED IN THE ARTERY. THE IFU ALSO STATE FAILURE TO MAINTAIN TENSION ON THE SUTURE WHILE ADVANCING THE COLLAGEN COULD CAUSE THE COLLAGEN TO ENTER THE ARTERY. THE ANGIO-SEAL IFU PRECAUTIONS THE USE OF THE ANGIO-SEAL DEVICE IN PTS WITH CLINICALLY SIGNIFICANT PERIPHERAL VASCULAR DISEASE."
        }
      ],
      "number_patients_in_event": "",
      "distributor_name": "",
      "manufacturer_g1_address_1": "",
      "distributor_zip_code": "",
      "manufacturer_contact_postal_code": "",
      "manufacturer_contact_exchange": "",
      "manufacturer_contact_pcountry": "",
      "suppl_dates_fda_received": ""
    }
  ]
}