  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-11-18",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 4
    }
  },
  "results": [
    {
      "manufacturer_contact_zip_ext": "",
      "manufacturer_g1_address_2": "",
      "event_location": "",
      "report_to_fda": "",
      "manufacturer_contact_t_name": "",
      "manufacturer_contact_state": "",
      "manufacturer_link_flag": "Y",
      "manufacturer_contact_address_2": "",
      "manufacturer_g1_city": "",
      "manufacturer_contact_address_1": "",
      "manufacturer_contact_pcity": "",
      "event_type": "Injury",
      "report_number": "2032108-2008-00001",
      "type_of_report": [
        "Initial submission"
      ],
      "product_problem_flag": "N",
      "date_received": "20080605",
      "manufacturer_address_2": "",
      "pma_pmn_number": "K972093",
      "date_of_event": "20080505",
      "reprocessed_and_reused_flag": "N",
      "manufacturer_address_1": "",
      "exemption_number": "",
      "manufacturer_contact_zip_code": "",
      "reporter_occupation_code": "OTHER",
      "manufacturer_contact_plocal": "",
      "noe_summarized": "1",
      "manufacturer_contact_l_name": "",
      "source_type": [
        "Health Professional"
      ],
      "distributor_zip_code_ext": "",
      "manufacturer_g1_postal_code": "",
      "manufacturer_g1_state": "",
      "reporter_country_code": "US",
      "manufacturer_contact_area_code": "",
      "date_added": "20080610",
      "manufacturer_contact_f_name": "",
      "previous_use_code": "",
      "device": [
        {
          "device_event_key": "",
          "implant_flag": "",
          "date_removed_flag": "",
          "device_sequence_number": "1",
          "date_received": "20080605",
          "brand_name": "PROVANT WOUND THERAPY SYSTEM",
          "generic_name": "SHORTWAVE DIATHERMY, NON-THERMAL",
          "manufacturer_d_name": "REGENESIS BIOMEDICAL, INC.",
          "manufacturer_d_address_1": "",
          "manufacturer_d_address_2": "",
          "manufacturer_d_city": "SCOTTSDALE",
          "manufacturer_d_state": "AZ",
          "manufacturer_d_zip_code": "",
          "manufacturer_d_zip_code_ext": "",
          "manufacturer_d_country": "US",
          "manufacturer_d_postal_code": "",
          "device_operator": "LAY USER/PATIENT",
          "model_number": "4201",
          "catalog_number": "",
          "lot_number": "",
          "other_id_number": "",
          "device_availability": "Yes",
          "date_returned_to_manufacturer": "20080520",
          "device_report_product_code": "ILX",
          "device_age_text": "DA",
          "device_evaluated_by_manufacturer": "Y",
          "combination_product_flag": "N",
          "udi_di": "",
          "udi_public": "",
          "openfda": {
            "device_name": "Diathermy, Shortwave, For Use Other Than Applying Therapeutic Deep Heat",
            "medical_specialty_description": "Physical Medicine",
            "regulation_number": "890.5290",
            "device_class": "2",
            "registration_number": [
              "2032108"
            ],
            "fei_number": [
              "3003070149"
            ]
          }
        }
      ],
      "product_problems": [
        "Unknown (for use when the device problem is not known)"
      ],
      "reporter_state_code": "WY",
      "manufacturer_zip_code": "",
      "suppl_dates_mfr_received": "",
      "mfr_report_type": "Thirty-Day",
      "manufacturer_contact_country": "",
      "date_changed": "20250824",
      "health_professional": "",
      "summary_report_flag": "N",
      "manufacturer_g1_zip_code_ext": "",
      "manufacturer_contact_extension": "",
      "manufacturer_city": "",
      "manufacturer_contact_phone_number": "",
      "patient": [
        {
          "patient_sequence_number": "1",
          "date_received": "20080605",
          "sequence_number_treatment": [
            "MORPHINE",
            " FUROSEMIDE",
            " BROMIDE",
            " IPRATOPIUM",
            " HYDROXYSINE",
            " TELFA",
            " HYPAFIX",
            " COLCHICINE",
            " OXYCODONE",
            " CALCIUM",
            " ASA",
            " ALLOPURINOL",
            " MEDS: ALBUTEROL",
            " COMPRESSION",
            " WOUND CARE WITH PANAFIL",
            " SPIRONOLACTONE",
            " DIAZEPAM",
            " FLUNISOLIDE"
          ],
          "sequence_number_outcome": [
            "Other"
          ],
          "patient_age": "73 YR",
          "patient_sex": "",
          "patient_weight": "89",
          "patient_ethnicity": "",
          "patient_race": "",
          "patient_problems": [
            "Bacterial Infection",
            "Blister(s)",
            "Erythema",
            "Inflammation",
            "Necrosis",
            "Pain",
            "Skin Irritation",
            "Burning Sensation",
            "Discomfort",
            "Surgical procedure",
            "Therapy/non-surgical treatment, additional",
            "Burn, Thermal",
            "Treatment with medication(s)",
            "Hospitalization required"
          ]
        }
      ],
      "distributor_city": "",
      "date_report": "20080605",
      "initial_report_to_fda": "",
      "distributor_state": "",
      "event_key": "",
      "manufacturer_g1_country": "",
      "manufacturer_contact_city": "",
      "mdr_report_key": "1057124",
      "removal_correction_number": "",
      "number_devices_in_event": "",
      "manufacturer_name": "",
      "report_source_code": "Manufacturer report",
      "remedial_action": [
        ""
      ],
      "manufacturer_g1_zip_code": "",
      "report_to_manufacturer": "",
      "manufacturer_zip_code_ext": "",
      "manufacturer_g1_name": "",
      "adverse_event_flag": "Y",
      "distributor_address_1": "",
      "manufacturer_state": "",
      "distributor_address_2": "",
      "manufacturer_postal_code": "",
      "single_use_flag": "",
      "manufacturer_country": "",
      "mdr_text": [
        {
          "mdr_text_key": "17728314",
          "text_type_code": "Description of Event or Problem",
          "patient_sequence_number": "1",
          "text": "PT TREATED FOR BILATERAL LOWER LEG ISCHEMIC ULCERS USING PROVANT AND PANAFIL IN ADDITION TO BASIC WOUND CARE. DURATION OF THERAPY 12 DAYS AND > 12 DAYS RESPECTIVELY. PT NOTED SKIN IRRITATION AND DISCOMFORT INTERMITTENTLY WITH PANAFIL OINTMENT APPLICATION, ESPECIALLY WHEN OINTMENT SPREAD ONTO ADJACENT SKIN. UPON INITIATION OF PROVANT, PT NOTED PROGRESSIVE  BURNING SENSATION ASSOCIATED WITH TREATMENT SESSIONS, INVOLVING ONLY THE RIGHT ANKLE ULCER (AND NOT THE LEFT ANKLE ULCER DESPITE BOTH RECEIVING IDENTICAL THERAPY). DESPITE MEASURABLE IMPROVEMENT IN THE RIGHT AND LEFT LEG ULCERS, BOTH TREATMENTS WERE DISCONTINUED IN 2008, IN RESPONSE TO THE ON-GOING BURNING SYMPTOMS AND PERI-WOUND ERYTHEMA. PT PRESENTED TO ER TWO DAYS LATER DUE TO SEVERE PAIN ABOUT THE RIGHT ANKLE, AND WAS FOUND TO HAVE A SMALL AREA OF BLISTERING AND NECROSIS ADJACENT TO THE WOUND, SUGGESTIVE OF A 3RD DEGREE BURN. THE WOUND WAS DEBRIDED AND TREATED CONSERVATIVELY WITH ANTIBIOTICS. PAIN AND BURN CHANGES RESOLVED OVER SEVERAL DAYS OF ANTIBIOTICS AND BASIC WOUND CARE. THE LEFT LEG ISCHEMIC ULCER HAD BEEN TREATED WITH THE SAME PROVANT DEVICE AND THE SAME PANAFIL OINTMENT TUBE AS THE RIGHT ULCER, BUT NEVER BECAME SYMPTOMATIC NOR EVIDENCED ANY ADVERSE EFFECT. PT CONTINUES TO DO WELL AT 1 MONTH FOLLOW UP."
        },
        {
          "mdr_text_key": "17963399",
          "text_type_code": "Additional Manufacturer Narrative",
          "patient_sequence_number": "1",
          "text": "CONCLUSIONS: DEVICE OPERATES ACCORDING TO SPECIFICATIONS. DEVICE IS WITHIN CALIBRATION. NO FAILURE DETECTED. CAUSE OF UNUSUAL EVENT UNK."
        }
      ],
      "number_patients_in_event": "",
      "distributor_name": "",
      "manufacturer_g1_address_1": "",
      "distributor_zip_code": "",
      "manufacturer_contact_postal_code": "",
      "manufacturer_contact_exchange": "",
      "manufacturer_contact_pcountry": "",
      "suppl_dates_fda_received": ""
    }
  ]
}