{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-08-05",
    "results": {
      "skip": 2500,
      "limit": 1,
      "total": 39677
    }
  },
  "results": [
    {
      "status": "Ongoing",
      "city": "Northfield",
      "state": "IL",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "95415",
      "recalling_firm": "MEDLINE INDUSTRIES, LP - Northfield",
      "address_1": "3 Lakes Dr",
      "address_2": "N/A",
      "postal_code": "60093-2753",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Two or more of the following: Email, Fax, Letter, Press Release, Telephone, Visit",
      "distribution_pattern": "Worldwide distribution - US Nationwide and the countries of Canada, Panama.",
      "recall_number": "Z-0165-2025",
      "product_description": "Medline brand medical procedure convenience kits, labeled as:    a) PLASTIC PACK, REF DYNJ42735A;   b) DR SELEM PACK, REF DYNJ43457;   c) BREAST PK TEGH-LF, REF DYNJ46717A;   d) BREAST PK TEGH-LF, REF DYNJ46717A;   e) BREAST BIOPSY-LF, REF DYNJ53205B;   f) BREAST BIOPSY-LF, REF DYNJ53205B;   g) PLASTIC PACK, REF DYNJ57895;   h) SEPTOPLASTY PACK WRO-LF, REF DYNJ62803;   i) BREAST PACK, REF DYNJ64376;   j) CSTM PK SURGISTART MAINE PLAST, REF DYNJ66619A;   k) PLASTIC PACK, REF DYNJ68030;   l) CUSTOM PLASTIC PACK, REF DYNJ68062;   m) PLASTIC LIMB SJHC-LF, REF DYNJ84997",
      "product_quantity": "1048 units",
      "reason_for_recall": "It has been determined that certain Convenience kits that were packaged in breather pouch lot 323080002 may result in the potential of using non-sterile product if the vendor seal of the pouch is opened/unsealed.",
      "recall_initiation_date": "20240904",
      "center_classification_date": "20241023",
      "report_date": "20241030",
      "code_info": "a) DYNJ42735A, UDI/DI 40888277226433 (each), 10888277226432 (case), Lot Numbers:  23LBP975;  b) DYNJ43457, UDI/DI 40888277055309 (each), 10888277055308 (case), Lot Numbers:  23LBS052;  c) DYNJ46717A, UDI/DI 40193489650014 (each), 10193489650013 (case), Lot Numbers:  24ABF270;  d) DYNJ46717A, UDI/DI 40193489650014 (each), 10193489650013 (case), Lot Numbers:  23LBO013;  e) DYNJ53205B, UDI/DI 40193489424851 (each), 10193489424850 (case), Lot Numbers:  24ABC805;  f) DYNJ53205B, UDI/DI 40193489424851 (each), 10193489424850 (case), Lot Numbers:  23LBN742;  g) DYNJ57895, UDI/DI 40889942790372 (each), 10889942790371 (case), Lot Numbers:  23KBF265;  h) DYNJ62803, UDI/DI 40193489688994 (each), 10193489688993 (case), Lot Numbers:  23LBN303;  i) DYNJ64376, UDI/DI 40193489807845 (each), 10193489807844 (case), Lot Numbers:  24ABD094;  j) DYNJ66619A, UDI/DI 40195327427840 (each), 10195327427849 (case), Lot Numbers:  23LBU414;  k) DYNJ68030, UDI/DI 40193489469289 (each), 10193489469288 (case), Lot Numbers:  23LBL117;  l) DYNJ68062, UDI/DI 40193489474580 (each), 10193489474589 (case), Lot Numbers:  24ABC304;  m) DYNJ84997, UDI/DI 40195327444212 (each), 10195327444211 (case), Lot Numbers:  23LBK468",
      "more_code_info": ""
    }
  ]
}