{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-10-28",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 211
    }
  },
  "results": [
    {
      "status": "Ongoing",
      "city": "Gainesville",
      "state": "FL",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "94092",
      "recalling_firm": "Exactech, Inc.",
      "address_1": "2320 Nw 66th Ct",
      "address_2": "",
      "postal_code": "32653-1630",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "Nationwide and Australia, Austria, Belgium, Brazil, Chile, Canada , China, Colombia, France, Germany, Great Britain, Greece, Guatemala, India, Italy, Japan, Korea, Luxembourg, Malaysia, Netherlands, New Zealand, Portugal, Singapore, South Africa, Spain, Sweden, Switzerland, Thailand",
      "recall_number": "Z-1409-2024",
      "product_description": "Exactech Equinoxe GLENOID,POSTERIOR AUGMENT, PEGGED, 12o, RIGHT, FOR CEMENTED USE ONLY, Mates with:    a) 38, 41, 44, 47 head, Small, Item Number 314-04-32,   b) 41, 44, 47, 50 head, Medium,  Item Number 314-04-33,   c) 44, 47, 50, 53 head, Large,  Item Number 314-04-34,   d) 44, 47, 50, 53 head, Extra Large,  Item Number 314-04-35; Shoulder Arthroplasty",
      "product_quantity": "39 units",
      "reason_for_recall": "The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer consisting of Ethylene Vinyl Alcohol (EVOH).",
      "recall_initiation_date": "20240306",
      "center_classification_date": "20240329",
      "report_date": "20240410",
      "code_info": "a) Item Number 314-04-32, UDI/DI 10885862199553, Serial Numbers:  2111957, 2161636, 2111956, 2161639, 3755661;   b) Item Number 314-04-33, UDI/DI 10885862199560, Serial Numbers:  2112015, 2112016, 2112013, 2112014, 2136760, 2136755, 2424239, 2424237, 2136756, 2424241, 2712715, 3892095, 3892094;   c) Item Number 314-04-34, UDI/DI 10885862199577, Serial Numbers:  2111987, 2111986, 2111984, 2138759, 2138757, 2138754, 2138756, 2138755, 2138753, 2425638, 2485901, 2425634, 2138758, 2111985, 2425636, 2425629, 2425627, 2425625;   d) Item Number 314-04-35, UDI/DI 10885862199584, Serial Numbers:  2111991, 2430293, 2430292",
      "more_code_info": ""
    }
  ]
}