{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-07-01",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "status": "Ongoing",
      "city": "Northfield",
      "state": "IL",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "99062",
      "recalling_firm": "Medline Industries, LP",
      "address_1": "3 Lakes Dr",
      "address_2": "N/A",
      "postal_code": "60093-2753",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "US Nationwide distribution including in the states of AL, AR, AZ, CA, CO, CT, FL, GA, IL, KS,  KY, LA, MA, MD, MI, MN, MO, MS, MT, NE, NJ, NM, NV, NY, OH, OK, OR, PA, RI, TN, TX, VA, WI,  WY and the country of Barbados.",
      "recall_number": "Z-2592-2026",
      "product_description": "Convenience kits containing select SKUs of 10mL Polycarbonate Colored Syringes.    ANGIO DRAPE PACK (ADLUG)642-LF\t  \tDYNJ47665D  \t  ANGIO PACK\t  \tDYNJ30565D  \t  ANGIOGRAPHY PACK-LF\t  \tDYNJ0854485V  \t  ARTERIOGRAM\t  \tDYNJ28082D  \tDYNJ28082F  \t  CARDIAC CATH\t  \tDYNJ67349  \t  CARDIAC CATH PACK\t  \tDYNJ57874C  \t  CATH I PLUS-LF\t  \tDYNJSCL100  \t  CATH III PLUS-LF\t  \tDYNJSCL300  \t  CATH LAB ANGIOGRAPHY PACK\t  \tDYNJ50779F  \t  CATH LAB PACK\t  \tDYNJ41088B  \tDYNJ48085  \t  CATH LAB TRAY\t  \tDYNJ37389N  \tDYNJ37389O  \t  CATH PACK\t  \tDYNJ62595A  \tDYNJ69997  \t  EP DRAPE PACK-LF\t  \tDYNJ47645B  \t  HOSPITAL REGIONAL DE CONCEPCIO\t  \tDYNJ67918A  \t  INTERVENTIONAL PACK\t  \tDYNJ56666C  \t  INTERVENTIONAL RAD PACK\t  \tDYNJ44100L  \t  INTERVENTIONAL RADIOLOGY PACK\t  \tDYNJ43664  \t  INTERVENTIONAL RADIOLOGY PK-LF\t  \tDYNJ0516014AF  \t  OR HYBRID-MRMC\t  \tDYNJ907758A  \t  VMA TRAY\t  \tDYNJ62376A",
      "product_quantity": "113, 843 kits",
      "reason_for_recall": "Firm identified unapproved design changes to the products outside of the 510(k) cleared by the FDA.  Products not initially reported in RES 98601.",
      "recall_initiation_date": "20260227",
      "center_classification_date": "20260625",
      "report_date": "20260701",
      "code_info": "DYNJ47665D    UDI-DI 10193489952827    Lots 21HBJ571   21JBD819   21LBA976   22BBP310   22CBW541   22CMH003   22DMD476   22EMA241   22FMF056   22HMC694   22HME818   22IMC158   22IMG796   22JMD311   22LMD944   22NBC196   23AMB219    DYNJ30565D    UDI-DI 10193489905205    Lots 21FDB653   21GDB275    DYNJ0854485V    UDI-DI 10195327096885    Lots 22CMB440   22EMF763   22HMA699   22HMG186   22IMD134   22LME930   23BMC883   23CMB807   23CMI020    DYNJ28082D    UDI-DI 10193489268676    Lots 21ABN806   21BBP110   21DBL217   21EBS784   21FBU514  DYNJ28082F    UDI-DI 10193489949452    Lots 21HBM290   21IBQ174   21KBO096   21KBO098    DYNJ67349    UDI-DI 10193489895728    Lots 23JMA721   24BMF147    DYNJ57874C    UDI-DI 10193489976618    Lot 24ABM611    DYNJSCL100    UDI-DI 10884389625583    Lot 24ABM801    DYNJSCL300    UDI-DI 10884389625606    Lot 24ABM802    DYNJ50779F    UDI-DI 10193489436068    Lots 21DME914   21EMF097   21GMB502   21JMA420   22BMA533   22BMB246   22DMA002   22DMD984   22DMI243   22EMG746   22GMB725   22HMH063   22IME310   22KMA626   23AME217   23BME137   23DMH595   23EMI849   23FMJ773   23JMB530   23LMH087   24BMF696   24CMJ355   24DMA986    DYNJ41088B    UDI-DI 10889942632794    Lot 21ABG127  DYNJ48085    UDI-DI 10888277546035    Lot 24AMF987    DYNJ37389N    UDI-DI 10193489306019    Lots 21ABN379   21CBU277   21DBP810  DYNJ37389O    UDI-DI 10193489925302    Lots 21FBL377   21GBD005   21HBN337   21JBW141   21JBW142   21LBG627   22ABH544   22CBF313   22DBD511   22DBE512   22FBS027    DYNJ62595A    UDI-DI 10193489364262    Lots 21ABH085   21ABI181   21ABV975   21BBO277   21CBU091   21EBA810  DYNJ69997    UDI-DI 10195327004743    Lots 22DBK793   22IBD718   22IBE297   22OBC253    DYNJ47645B    UDI-DI 10193489952834    Lots 21GBM457   21IBV915   21KBF627   21LBA512   21LME436   22DMI445   22EMD836   22FMC418   22GME258   22KMD663    DYNJ67918A    UDI-DI 10195327042776    Lots 21LBP804   22CBZ026   22CBZ027   22OBG779    DYNJ56666C    UDI-DI 10193489876079    Lots 21GMD986   21IMF632   21KMI417   22BMG174   22EMC819   22GMA609   22HMB858   22IME607   22JMI267   22LMA954   22LMH272   23BMH725    DYNJ44100L    UDI-DI 10193489808810    Lots 20LMF752   21AMD830   21BMB938   21DMB287   21FMA141   21GMF673   21HMF024   21JMH879   21LMD528   22AME658   22CMD992   22DME753   22EMI131   22FMD999   22GMA910   22HMG804   22KMC260   22LMF595    DYNJ43664    UDI-DI 10888277065475    Lot 22FBP452    DYNJ0516014AF    UDI-DI 10193489346978    Lots 21ABD076   21FBH595   21HBP277   21IBX390   21KBK660   22BBF662   22CBA986   22CBQ787   22DBI149   22FMC751   22FMF379   22IMA038   22IMH722    DYNJ907758A    UDI-DI 10193489978384    Lot 21KBQ655    DYNJ62376A    UDI-DI 10193489933598    Lot 24ABP679"
    }
  ]
}