{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-07-01",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "status": "Ongoing",
      "city": "Sunnyvale",
      "state": "CA",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "98701",
      "recalling_firm": "Intuitive Surgical, Inc.",
      "address_1": "1266 Kifer Rd",
      "address_2": "N/A",
      "postal_code": "94086-5304",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "Worldwide - US Nationwide distribution including in the states of CA, GA, OH, PA, NY, MN, TN, OR, IL, MD, NJ, AL, NV, TX, FL, LA, CT, NC, AZ, IA, MO, WA, MI, WV, WI, KY, KS, VA, OK, MA, IN, CO, SC, SD, MS, NH, UT, ME and the countries of Belgium, Denmark, Sweden, France, Japan, Germany, Israel, Switzerland, South Korea, Czech Republic, Austria, United Kingdom, Italy, Spain, Ireland, Saudi Arabia, Greece, Taiwan, Australia, China, Turkey, Poland, United Arab Emirates, Hong Kong, Romania.",
      "recall_number": "Z-2521-2026",
      "product_description": "Da Vinci ASSY, PSS, SP1098, Part Number: 380601",
      "product_quantity": "454",
      "reason_for_recall": "Operative components of surgical systems potentially distributed with E-brake retainer pin, so in event of a structural column failure, the E-brake pin would prevent E-brake engagement and may result in uncontrolled motion. In addition, if it moves/backs out it may cause restricted column range of motion and/or uncontrolled motion, which may cause patient tissue injury/crushing injury/bleeding.",
      "recall_initiation_date": "20260422",
      "center_classification_date": "20260622",
      "report_date": "20260701",
      "code_info": "UDI: 00886874114605. Serial Numbers: 605408, 606848, 612328, 628399, 609353, 614073, 617794, 616769, 10008062, 635659, 631694, 638771, 641430, 694998, 645433, 643209, 954097, 656203, 764644, 656319, 946098, 667190, 666480, 655562, 664662, 680530, 679266, 683974, 674171, 676962, 682694, 686777, 701248, 696877, 688725, 688225, 697922, 700316, 698277, 702699, 709536, 701751, 717804, 705366, 704731, 724178, 703152, 722803, 693262, 736468, 736338, 740359, 742366, 732233, 696089, 724835, 716520, 709987, 728391, 751529, 731765, 672743, 766366, 711517, 735003, 735252, 746457, 746623, 718940, 721722, 691190, 744094, 750174, 738718, 10211920, 759253, 761448, 752536, 812651, 754935, 790597, 811147, 793019, 761000, 812650, 919988, 919987, 913011, 913012, 926423, 759791, 926422, 938794, 771653, 938795, 766365, 963841, 797872, 769736, 794437, 970568, 970562, 977045, 10003059, 957781, 973824, 804588, 10009706, 936269, 10003509, 930240, 936268, 800142, 10003510, 982782, 967667, 10009707, 973355, 944585, 10065786, 935214, 10020729, 10012963, 10020705, 10031145, 10031144, 973825, 10012962, 10036960, 963856, 10711066, 10035476, 795038, 10043635, 944583, 10072852, 10072853, 966079, 10069899, 10076490, 10087446, 10054478, 10080929, 954096, 10130089, 10165287, 942811, 10180162, 10172589, 10103483, 10103484, 10056518, 10092007, 10246370, 10209961, 10183740, 10232634, 504007, 10231116, 10211880, 10194911, 10245457, 10112470, 10189443, 977044, 10238314, 10644376, 10036961, 10274101, 10112471, 10238315, 10172574, 10281524, 10278366, 10252751, 10289629, 10293276, 10261900, 10274102, 10285085, 10281525, 10243796, 10267796, 10278365, 10285084, 10308532, 10318311, 10293274, 10323177, 10322512, 10289630, 10326939, 10293275, 10333333, 10326938, 10492299, 10302474, 10302473, 10368392, 10332310, 10346946, 10354749, 10346943, 10333332, 10346942, 10267795, 10323178, 10295600, 10223509, 10252780, 10396330, 10263730, 10354748, 10337879, 10265272, 10354750, 10384455, 10359960, 10368393, 10366206, 10375031, 10363897, 10396329, 10363898, 10375032, 10375033, 10409934, 10401560, 10409933, 10408268, 10294693, 10408269, 10396331, 10480883, 10499186, 10499185, 10384456, 10502598, 10495654, 10502599, 10505838, 10512168, 10512167, 10512166, 10508290, 10368391, 10556776, 10417803, 10526733, 10417164, 10508289, 10384454, 10492298, 10480878, 10526735, 10526736, 10537191, 10495655, 10526734, 10526732, 530114, 10537202, 10568118, 10308533, 10547839, 10564979, 10550219, 10564978, 10550220, 10550221, 10561240, 10594744, 10575228, 10571615, 10575229, 10583123, 10571614, 10556769, 10583124, 10594746, 10556777, 10564977, 10594743, 10579531, 10613173, 10568117, 10571616, 10615325, 10583126, 10619701, 10594742, 10541679, 10579530, 10561239, 10594745, 10615326, 10590323, 10590322, 10583125, 10615941, 10608089, 10644375, 10604955, 10561241, 10624252, 10647203, 10670710, 10672825, 10624990, 10295599, 10633489, 10622883, 10647201, 10624251, 10686903, 10612973, 10619702, 10672839, 10696000, 10615940, 10659191, 10651445, 10651443, 10682596, 10702363, 10644374, 10653815, 10651444, 10627633, 10686902, 10672840, 10627632, 10695999, 10665125, 10604956, 10480877, 10682597, 10694981, 10633487, 10716881, 10659189, 10728578, 10627631, 10702364, 10734551, 10659190, 10633488, 10734552, 10706206, 650202, 10744259, 10706207, 10766233, 10766236, 10793380, 10759158, 10759159, 10759161, 10763608, 10763609, 10808841, 10766234, 10763611, 10741377, 10759160, 10763610, 10826493, 10776325, 10766235, 10741378, 10744258, 10734553, 10808839, 10808840, 10771126, 10803470, 10793379, 10817400, 10798922, 10803484, 10766232, 10887260, 10830719, 10771125, 10776323, 10815457, 10744257, 10823000, 10776324, 10782092, 10873054, 10879012, 10897582, 10856718, 10889592, 10864698, 10922820, 10912617, 10647204, 10869722, 10889594, 10871773, 10845441, 10859690, 10826495, 10579532, 10782090, 10826494, 10792831, 10883203, 10871774, 10856716, 10856732, 10859689, 10947466, 10798915, 10968849, 10952495, 10957321, 10875232, 10903586, 10927370, 10947464, 10951328, 10981839, 10787962, 10908841, 10908842, 10817401, 10938311, 10933815, 10938312, 10955031, 10927371, 10933816, 10998396, 10927372, 10240354, 10998395, 11004904, 10979952, 10875231, 10912618, 10897581, 10938310, 10991256, 10991257, 10991259, 10895278, 10883202, 10889593, 10912619, 11016764, 11013103"
    }
  ]
}