      "status": "Ongoing",
      "city": "Gainesville",
      "state": "FL",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "90279",
      "recalling_firm": "Exactech, Inc.",
      "address_1": "2320 Nw 66th Ct",
      "address_2": "",
      "postal_code": "32653-1630",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "E-Mail",
      "distribution_pattern": "Worldwide distribution: US (nationwide) and OUS (foreign) countries of: ARGENTINA, BRAZIL, CHILE, CHINA, COLOMBIA, ECUADOR, GREECE, GUATEMALA, INDIA, LEBANON PORTUGAL,PUERTO RICO,SPAIN",
      "recall_number": "Z-1727-2022",
      "product_description": "GXL acetabular liners, orthopedic hip implant component.   Product Line Numbers:    a. ACUMATCH +5MM LAT LINER 15 DEG 36MM ID, SIZE H, REF 138-36-08  b. ACUMATCH +5MM LAT LINER 15 DEG 36MM ID, SIZE J, REF 138-36-09  c. ACUMATCH LINER 15 DEG 36MM ID, SIZE H, REF 132-36-08  d. ACUMATCH LINER 15 DEG 36MM ID, SIZE J, REF 132-36-09  e. ACUMATCH LINER 15 DEG 36MM ID, SIZE K, REF 132-36-10",
      "product_quantity": "132 devices",
      "reason_for_recall": "Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear.",
      "recall_initiation_date": "20220811",
      "center_classification_date": "20220909",
      "report_date": "20220921",
      "code_info": "a. REF 138-36-08, GUDID 10885862024787,  Serial Numbers:  638430, 638433, 638451,  638462, 638467;   b. REF 138-36-09, GUDID 10885862024794,  Serial Numbers:  635279, 635281;   c. REF 132-36-08, GUDID 10885862023353,  Serial Numbers:  630606, 630607, 630609, 630610, 630611, 630612, 630613, 632796, 632797, 632799, 632800, 632801, 632802, 632803, 632805, 632806, 632807, 632808, 632809, 632810, 632812, 632813, 632814, 632815, 632817, 632818, 632819, 632822, 632823, 632824, 632826, 632829, 632830, 632832, 632834, 657859, 657861, 657862, 657863, 657865, 657866, 657867, 657868, 657869, 657870, 657871, 657873, 657875, 657876, 657877, 657878, 657880, 657882, 657883, 657885, 657886, 657887, 657888, 657890, 657891, 657892, 1116881, 1116882, 1116883, 1116886, 1116887, 1116888, 1116889, 1116890, 1116892, 1116896, 1116897, 1116899, 1116903, 1116904, 1116905;   d. REF 132-36-09, GUDID 10885862023360,  Serial Numbers:  638946, 638947, 638950, 643861, 643862, 643863, 643864, 643865, 643866, 643867, 643868, 643869, 643870, 643871, 643872, 643874, 643876, 643877, 643878, 643879, 643880, 643881, 643882, 643883, 643884, 645796, 645798, 645799, 645800, 645801, 645802, 645803, 645805, 645806, 645807, 828079, 828082, 828083, 828084, 828085, 828086, 828088, 828089, 828090, 828091, 828092, 1634294, 2754889;   e. REF 132-36-10, GUDID 10885862023377,  Serial Numbers:  632861.",
      "more_code_info": ""
    }
  ]
}