      "status": "Ongoing",
      "city": "Gainesville",
      "state": "FL",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "94092",
      "recalling_firm": "Exactech, Inc.",
      "address_1": "2320 Nw 66th Ct",
      "address_2": "",
      "postal_code": "32653-1630",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "Nationwide and Australia, Austria, Belgium, Brazil, Chile, Canada , China, Colombia, France, Germany, Great Britain, Greece, Guatemala, India, Italy, Japan, Korea, Luxembourg, Malaysia, Netherlands, New Zealand, Portugal, Singapore, South Africa, Spain, Sweden, Switzerland, Thailand",
      "recall_number": "Z-1410-2024",
      "product_description": "Exactech Equinoxe GLENOID,POSTERIOR AUGMENT, PEGGED, 16o, LEFT, FOR CEMENTED USE ONLY, Mates with:    a) 38, 41, 44, 47 head, Small, Item Number 314-06-22,   b) 41, 44, 47, 50 head, Medium,  Item Number 314-06-23,   c) 44, 47, 50, 53 head, Large,  Item Number 314-06-24,   d) 44, 47, 50, 53 head, Extra Large,  Item Number 314-06-25; Shoulder Arthroplasty",
      "product_quantity": "180 units",
      "reason_for_recall": "The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer consisting of Ethylene Vinyl Alcohol (EVOH).",
      "recall_initiation_date": "20240306",
      "center_classification_date": "20240329",
      "report_date": "20240410",
      "code_info": "a) Item Number 314-06-22, UDI/DI 10885862228307, Serial Numbers:  2579212, 2634987, 2635008, 2579195, 2579206, 2811940, 2811957, 2811935, 2634983, 5718616, 5718644, 5718619, 5933499, 5933502, 5704955, 6756450, 6756452, 5718637, 5933505, 6756441, 6756445, 6756449, 6756455, 5933325, 5933336, 6756451;   b) Item Number 314-06-23, UDI/DI 10885862228314, Serial Numbers:  2579171, 2579188, 2635070, 2635068, 2579173, 2635067, 2635101, 2635061, 2635071, 2635064, 2823506, 2823492, 2579179, 2579187, 2635077, 2635078, 2635079, 2635082, 2579172, 4209444, 4209441, 3810131, 2823487, 2811883, 2635086, 2635100, 4209447, 2823504, 2823511, 2635057, 4209454, 3810133, 5247720, 5247712, 5247733, 4209436, 4209451, 5244109, 5247721, 5244110, 5369572, 5600215, 5600216, 5679291, 5369568, 5369563, 5247729, 5369582, 5369569, 5369570, 5369562, 6195298, 5929433, 6611524, 6611529, 6237444, 6195311, 5369578, 5369577, 5369564, 5583201, 6611525, 6611527, 6611530, 6611532, 6237443, 6237446, 6237448;   c) Item Number 314-06-24, UDI/DI 10885862228321, Serial Numbers:  2635040, 2579234, 2635025, 2816589, 2816585, 2579228, 2579235, 2579229, 2635020, 2635050, 2635032, 2635039, 2816586, 2823519, 2816606, 2823524, 2579225, 2635016, 2579220, 2635029, 2635047, 2579215, 2816588, 2635035, 2816625, 3876622, 2823533, 2816613, 2823521, 5305367, 5305350, 5600031, 5554824, 5554813, 4209480, 4209466, 3794397, 5305372, 5305361, 5305349, 5753670, 5753659, 5305368, 5554812, 6006578, 5583280, 5305370, 5368871, 5554819, 6006580, 6195255, 6195269, 5753671, 6006579, 6006584, 6612218, 6612226, 6612228, 6612229, 6418445, 6418448, 6612220, 6612222, 6006569, 6195273, 6418446;   d) Item Number 314-06-25, UDI/DI 10885862228338, Serial Numbers:  2579243, 2579239, 2823562, 2618355, 2618388, 2618360, 2618398, 3810139, 5718648, 5301843, 5258719, 5730095, 5730085, 6534089, 6534098, 6037827, 6534084, 6534088, 6060453, 6534086",
      "more_code_info": ""
    }
  ]
}