  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-07-08",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "status": "Terminated",
      "city": "Basingstoke",
      "state": "N/A",
      "country": "United Kingdom",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "86801",
      "recalling_firm": "Remote Diagnostic Technologies Ltd.",
      "address_1": "PAVILION C2, ASHWOOD PARK",
      "address_2": "ASHWOOD WAY",
      "postal_code": "N/A",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "US Nationwide distribution.",
      "recall_number": "Z-0564-2021",
      "product_description": "Tempus LS - Manual Defibrillator, Model Number: 00-3020  Software Version: 1.3.4 - Product Usage: The device is intended to be used in the following environmental: - Primarily in pre-hospital care and transport applications (including ambulances, fixed and rotary wing aircraft).",
      "product_quantity": "175 devices",
      "reason_for_recall": "A software error was detected within software version 1.3.4 for the Tempus LS device. When exiting pacer back into manual mode the pacer pulse wave may put the ECG calibration out of calibration. This software error may result in a delay in therapy, as the clinician is not provided an ECG waveform on which a shockable rhythm decision can be made. The device is still able to deliver a manual defibrillation shock.",
      "recall_initiation_date": "20201117",
      "center_classification_date": "20201211",
      "termination_date": "20231212",
      "report_date": "20201223",
      "code_info": "UDI: 07613365002737  REF: 00-3020  Software Version Number: 1.3.4    Serial Numbers:  LS 7022.000218  LS 7022.000219  LS 7022.000221  LS 7022.000222  LS 7022.000223  LS 7022.000224  LS 7022.000201  LS 7022.000202  LS 7022.000203  LS 7022.000204  LS 7022.000225  LS 7022.000226  LS 7022.000214  LS 7022.000215  LS 7022.000216  LS 7022.000217  LS 7022.000150  LS 7022.000190  LS 7022.000189  LS 7022.000186  LS 7022.000188  LS 7022.000187  LS 7022.000186  LS 7022.000187  LS 7022.000188  LS 7022.000189  LS 7022.000190  LS 7022.000209  LS 7022.000143  LS 7022.000141  LS 7022.000276  LS 7022.000265  LS 7022.000110  LS 7022.000111  LS 7022.000152  LS 7022.000171  LS 7022.000172  LS 7022.000173  LS 7022.000174  LS 7022.000175  LS 7022.000176  LS 7022.000177  LS 7022.000178  LS 7022.000205  LS 7022.000156  LS 7022.000281  LS 7022.000234  LS 7022.000283  LS 7022.000247  LS 7022.000235  LS 7022.000260  LS 7022.000255  LS 7022.000246  LS 7022.000249  LS 7022.000284  LS 7022.000282  LS 7022.000251  LS 7022.000233  LS 7022.000250  LS 7022.000257  LS 7022.000248  LS 7022.000254  LS 7022.000256  LS 7022.000252  LS 7022.000258  LS 7022.000179  LS 7022.000142  LS 7022.000145  LS 7022.000154  LS 7022.000155  LS 7022-000139  LS 7022-000138  LS 7022.000140  LS 7022.000157  LS 7022.000160  LS 7022.000192  LS 7022.000191  LS 7022.000261  LS 7022.000262  LS 7022.000263  LS 7022.000213  LS 7022.000212  LS 7022.000211  LS 7022.000199  LS 7022.000197  LS 7022.000200  LS 7022.000193  LS 7022.000194  LS 7022.000198  LS 7022.000195  LS 7022.000206  LS 7022.000207  LS 7022.000208  LS 7022.000112  LS 7022.000113  LS 7022.000264  LS 7022.000266  LS 7022.000267  LS 7022.000268  LS 7022.000269  LS 7022.000270  LS 7022.000271  LS 7022.000272  LS 7022.000273  LS 7022.000274  LS 7022.000227  LS 7022.000228  LS 7022.000229  LS 7022.000230  LS 7022.000231  LS 7022.000232  LS 7022.000236  LS 7022.000237  LS 7022.000238  LS 7022.000239  LS 7022.000161  LS 7022.000162  LS 7022.000163  LS 7022.000164  LS 7022.000165  LS 7022.000166  LS 7022.000167  LS 7022.000168  LS 7022.000169  LS 7022.000170  LS 7022-000158  LS 7022.000103  LS 7022.000133  LS 7022.000134  LS 7022.000136  LS 7022.000144  LS 7022.000148  LS 7022.000149  LS 7022-000137  LS 7022.000153  LS 7022.000181  LS 7022.000180  LS 7022.000182  LS 7022.000185  LS 7022.000184  LS 7022.000183  LS 7022.000220  LS 7022.000147  LS 7022.000146  LS 7022.000130  LS 7022.000131  LS 7022.000132  LS 7022.000135  LS 7022.000159  LS 7022.000243  LS 7022.000244  LS 7022.000245  LS 7022.000242  LS 7022.000241  LS 7022.000102  LS 7022.000105  LS 7022.000106  LS 7022.000108  LS 7022.000109  LS 7022.000114  LS 7022.000115  LS 7022.000116  LS 7022.000117  LS 7022.000119  LS 7022.000120  LS 7022.000121  LS 7022.000122  LS 7022.000123  LS 7022.000124  LS 7022.000125  LS 7022.000126  LS 7022.000127  LS 7022.000128  LS 7022.000129  LS 7022.000151"
    }
  ]
}