  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-04-08",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "status": "Terminated",
      "city": "Gumi",
      "state": "N/A",
      "country": "Korea (the Republic of)",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "80944",
      "recalling_firm": "ShinChang Medical Co., Ltd.",
      "address_1": "144 1gongdan-Ro",
      "address_2": "N/A",
      "postal_code": "N/A",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "FL, TN, and VA",
      "recall_number": "Z-3202-2018",
      "product_description": "Disposable Insulin Syringe 0.3mL in 3 different sizes 29Gx1/2, 30Gx5/16, and 31G x 5/16.   (10 syringes are packaged in a flexible plastic (poly bag) and 10 flexible plastic (poly bag) are packaged in one in box. Finally, pack the inboxes in the carton case.)",
      "product_quantity": "6,570,800",
      "reason_for_recall": "Defect consists of a small crack in the top end of the barrel near the needle.",
      "recall_initiation_date": "20180824",
      "center_classification_date": "20180920",
      "termination_date": "20230104",
      "report_date": "20180926",
      "code_info": "GNP Insulin Syringe 0.3mL 31G¿5/16\" NP18127,  Healthmart Insulin Syringe 0.3mL 31G¿5/16\" NP18155,   Healthmart Insulin Syringe 0.3mL 31G¿5/16\" NP18186,   Kroger Insulin Syringe 0.3mL 30G¿5/16\" NP18082,  Kroger Insulin Syringe 0.3mL 31G¿5/16\" NP18083,  Kroger Insulin Syringe 0.3mL 30G¿5/16\" NP18126,  Kroger Insulin Syringe 0.3mL 30G¿5/16\" NP18146,  Kroger Insulin Syringe 0.3mL 31G¿5/16\" NP18157,  Leader Insulin Syringe 0.3mL 31G¿5/16\" NP18123,  Leader Insulin Syringe 0.3mL 31G¿5/16\" NP18130,  Leader Insulin Syringe 0.3mL 30G¿5/16\" NP18151,  Leader Insulin Syringe 0.3mL 31G¿5/16\" NP18161,  Leader Insulin Syringe 0.3mL 30G¿5/16\" NP18180,  Leader Insulin Syringe 0.3mL 31G¿5/16\" NP18202,  Nipro Insulin Syringe 0.3mL 31G¿5/16\" NP18125.  Nipro Insulin Syringe 0.3mL 30G¿5/16\" NP18129.  Nipro Insulin Syringe 0.3mL 31G¿5/16\" NP18142.  Nipro Insulin Syringe 0.3mL 31G¿5/16\" NP18170.  Nipro Insulin Syringe 0.3mL 29G¿1/2\" NP18196.  Nipro Insulin Syringe 0.3mL 30G¿5/16\" NP18197.  Nipro Insulin Syringe 0.3mL 30G¿5/16\" NP18199.  Sunmark Insulin Syringe 0.3mL 31G¿5/16\" NP18124,  Sunmark Insulin Syringe 0.3mL 30G¿5/16\" NP18128,  Sunmark Insulin Syringe 0.3mL 31G¿5/16\" NP18136,  Sunmark Insulin Syringe 0.3mL 31G¿5/16\" NP18166,    Sunmark Insulin Syringe 0.3mL 30G¿5/16\" NP18206,   Lite Touch Insulin Syringe 0.3mL 30G¿5/16\" LT1805, and   McKesson Insulin Syringe 0.3mL 31G¿5/16\" KSH0603."
    }
  ]
}