{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-04-22",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "status": "Terminated",
      "city": "Schaumburg",
      "state": "IL",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "68725",
      "recalling_firm": "Instrumed International, Inc.",
      "address_1": "626 Cooper Ct",
      "address_2": "N/A",
      "postal_code": "60173-4537",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "Distribution US Nationwide in the states of:  AL, AR, AZ, CA, CO, CT, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, MI, MN, MO, MS, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, WA, WI, WV, and WY.",
      "recall_number": "Z-2726-2014",
      "product_description": "Reusable laparoscopic instruments are packaged as non-sterile. Cleaning and sterilization of devices must occur prior to use.     The instruments are intended to be used by qualified physicians to provide access, illumination and visualization of internal structures and for manipulating soft tissue (grasping, cutting, coagulating, dissecting and suturing) in a wide variety of diagnostic and therapeutic laparoscopic/ urologic closed and minimally invasive procedures. It is inserted via a trocar sleeve and is used to prepare, coagulate and cut tissue.",
      "product_quantity": "122 instruments",
      "reason_for_recall": "Additional caution statements have been added to the Instructions For Use for monopolar electrodes.  1) To avoid tissue carbonation, the operation voltage of the HF generator must not exceed 650 peak voltage (Vp) for all monopolar electrodes.  and 2) For all monopolar electrodes, the useful life of this product is less than or equal to 50 cycles and less than or equal to 2 years.",
      "recall_initiation_date": "20140530",
      "center_classification_date": "20140930",
      "termination_date": "20171129",
      "report_date": "20141008",
      "code_info": "1) Instrumed Item No.: 250-08930; Specialty Care Catalog Code: 30-92221; Lot Number: 040413"
    }
  ]
}