      "status": "Terminated",
      "city": "Memphis",
      "state": "TN",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "71895",
      "recalling_firm": "Wright Medical Technology, Inc.",
      "address_1": "1023 Cherry Rd",
      "address_2": "N/A",
      "postal_code": "38117-5423",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "Nationwide Distribution",
      "recall_number": "Z-2541-2015",
      "product_description": "CrossCHECK  Locking Screw in the following sizes:  3.0 x 8 mm, REF CCP-L3008; 3.0 x 10 mm, REF CCP-L3010; 3.0 x 12 mm, REF CCP-L3012; 3.0 x 14 mm, REF CCP-L3014; 3.0 x 16 mm, REF CCP-L3016; 3.0 x 18 mm, REF CCP-L3018; 3.0 x 20 mm, REF CCP-L3020; 3.0 x 22 mm, REF CCP-L3022; 3.0 x 24 mm, REF CCP-L3024; 3.0 x 26 mm, REF CCP-L3026; 3.0 x 28 mm, REF CCP-L3028; 3.0 x 30 mm, REF CCP-L3030; 3.0 x 32 mm, REF CCP-L3032; 3.0 x 34mm, REF CCP-L3034; 3.0 x 36 mm, REF CCP-L3036; 3.0 x 38 mm, REF CCP-L3038; 3.0 x 40 mm, REF CCP-L3040; 3.5 x 8 mm, REF CCP-L3508; 3.5 x 10 mm, REF CCP-L3510; 3.5 x 12 mm, REF CCP-L3512; 3.5 x 14mm, REF CCP-L3514; 3.5 x 16 mm, REF CCP-L3516; 3.5 x 18 mm, REF CCP-L3518; 3.5 x 20 mm, REF CCP-L3520; 3.5 x 22 mm, REF CCP-L3522; 3.5 x 24 mm, REF CCP-L3524; 3.5 x 26 mm, REF CCP-L3526; 3.5 x 28 mm, REF CCP-L3528; 3.5 x 30 mm, REF CCP-L3530; 3.5 x 35 mm, REF CCP-L3532; 3.5 x 34 mm, REF CCP-L3534; 3.5 x 36 mm, REF CCP-L3536; 3.5 x 38 mm, REF CCP-L3538; 3.5 x 40 mm, REF CCP-L3540  The CROSSCHECK Plating System is indicated for stabilization and fixation of fresh fractures, revision procedures, joint fusion and reconstruction of small bones in the hand, feet wrist and ankles, fingers and toes. The system may be used in both pediatric and adult patients. The device is intended for single use.",
      "product_quantity": "107 units",
      "reason_for_recall": "These screws have a potential of passing through the plate in the case when torque is applied in excessive amounts, which may result in intraoperative malfunction.",
      "recall_initiation_date": "20150721",
      "center_classification_date": "20150901",
      "termination_date": "20180801",
      "report_date": "20150909",
      "code_info": "CrossCHECK  Locking Screw with the following codes:  REF CCP-L3008:  Lot Number 35000; REF CCP-L3010:  Lot Number 35000; REF CCP-L3012:  Lot Number 35000-6, 35000; REF CCP-L3014:  Lot Number 35000-8, 35000; REF CCP-L3016:  Lot Number 35000; REF CCP-L3018:  Lot Number 35000; REF CCP-L3020:  Lot Number 35000; REF CCP-L3022:  Lot Numbers: 35000-16-1, 35000; REF CCP-L3024:  Lot Number 35000; REF CCP-L3026:  Lot Number 35000; REF CCP-L3028:  Lot Number 35000; REF CCP-L3030:  Lot Number 35000; REF CCP-L3032:  Lot Number 35000; REF CCP-L3034:  Lot Number 35000; REF CCP-L3036:  Lot Number 35000; REF CCP-L3038:  Lot Number 35000;  REF CCP-L3040:  Lot Number 35000; REF CCP-L3508:  Lot Number 35004; REF CCP-L3510:  Lot Numbers: 35004-3, 35004; REF CCP-L3512:  Lot Numbers: 35004-6, 35004; REF CCP-L3514:  Lot Numbers: 35004-7, 35004; REF CCP-L3516:  Lot Number 35004; REF CCP-L3518:  Lot Numbers: 35004-12, 35004-12-1, 35004; REF CCP-L3520:  Lot Numbers: 35004-13, 35004; REF CCP-L3522:  Lot Numbers: 35004-16-1, 35004; REF CCP-L3524:  Lot Numbers: 35004-18-1, 35004; REF CCP-L3526:  Lot Number 35004; REF CCP-L3528:  Lot Number 35004; REF CCP-L3530:  Lot Number 35004; REF CCP-L3532:  Lot Number 35004; REF CCP-L3534:  Lot Number 35004; REF CCP-L3536:  Lot Number 35004; REF CCP-L3538:  Lot Number 35004; REF CCP-L3540:  Lot Number 35004"
    }
  ]
}