      "status": "Terminated",
      "city": "St Priest",
      "state": "",
      "country": "France",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "80312",
      "recalling_firm": "NewDeal SA",
      "address_1": "Immeuble Sequoia 2 97 A",
      "address_2": "97 Allee Alexandre Borodineimmeuble Sequoia 2 97 Allee Alexandre Borodine",
      "postal_code": "N/A",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "CA, CO, CT, ID, KS, MA, MD, MN, MO, MS, NC, NY, OH, OR, PA, SD, VA, WA & WI",
      "recall_number": "Z-2447-2018",
      "product_description": "TIBIAXYS, Model Numbers: 150010S, 150020S, 150030S, 150040S,   150120S, 150110S, 150130S, 150200S, 150240S, 150242S, 150246S,   150250S, 150255S, 150260S, 150265S, 150270S, 150275S, 150280S,   150285S, 150290S, 150514S & 150516S",
      "product_quantity": "",
      "reason_for_recall": "Use of the impacted product may cause a superficial infection requiring PO antibiotics and wound care or deep infection requiring IV antibiotics and device removal.",
      "recall_initiation_date": "20180522",
      "center_classification_date": "20180716",
      "termination_date": "20191104",
      "report_date": "20180725",
      "code_info": "150010S - Lot # F8X6 - F9K6 - F9YE-F9YH - FAC1 - FAFD-FBTV - FC90 - FC93-FD10 - FGL3 - FGL3/1-  150020S - Lot # F6R7 - F6R8 - F6R9-F8X7 - F8X8 - F9MH -FAA6 - FAU7 - FAU8-FAZW   FAZX - FAZY-FD11 - FD12 - FFGP-F8X7 - F8X8 - F9MH -FAA6 - FAU7 - FAU8-FAZW   FAZX - FAZY-FD11 - FD12 - FFGP-FGL1 - FGL2 - FH73-FH7S - FH7T & FJ4J  150030S - Lot # FGM5   FHRR  150040S - Lot # F6RA - F6RB - F7PB-F9KG   FAFE - FBTT-FC91 - FGL0 - FH7U  150120S - Lot # F77H - F77J - F77K-F9MJ - F9YF - F9YG-FAA7   FAZZ - FBTU-FC92 - FCV9 - FFGR-FGGY   FGGZ - FGM8-FGM9 - FH7W - FHK2  150110S - Lot # F97D - F9KH - FAU9-FCN0   FGGW - FGM7-FH7V & FJ4G   150130S - Lot # EB5W/G - EDJX/G   FAUA - FG0J & FJ4J  150200S - Lot # F6RR - F7X0 - F98B-FAWZ - FD8L - FD8M-FE2T - FEX8  150240S - Lot # F6RS - F88U - F9F1-FBBS - FD8N - FD8P-FE2U - FE2V - FE2W-FEX9 - FF1M - FFPT-FGNW - FGNX & FGNY  150242S - Lot # F6RU - F88V - F98F-FAX0 - FCB9 - FE2X-FE2Y - FE2Z - FF1N-FFPU   FFPV - FGNZ-FGX2 & FG7K  150246S - Lot # F6RV - F88W - F9F2-FBBT   FCBA - FD8Q-FE30 - FE31 - FE32-FE33   FEXA - FF1P-FFPW - FG7L - FGP0-FGX3   150250S - Lot # F6RW - F88X - F9F3-FBBU   FCPQ - FDSB-FDSC - FE34 - FE35-FEXB - FF1Q - FFPX -FG7M - FG7N - FGX4 & FHGG  150255S - Lot # F6YN - F6YN/1 - F6YN/2-F6YN/3 - F6YN/4 - F6YN/5 - F6YN/A---  150260S - Lot # F6RX - F7X1 - F8XU-F9F5 - FAX1 - FBBV-FCPR - FD8R - FE36-FE37 - FF1R - FFPY-FG7P  150265S - Lot # F6RY - F88Y - F989-F9F6 - F9VA - FCBB-FDSD - FE38 - FFPZ-FG7Q - FH2T-  150270S - Lot # F6RZ - F8LD - F9BX-F9VB   FBBW - FD8S-FE39 - FF1S - FG7R & FHGJ  150275S - Lot # F6S0 - F88Z - F98A-F9BW   FBBX - FCPS-FE3A   FEXC  150280S - Lot # F6S1 - F7X2 - F98D-FAPQ   FBBY - FCPT-FE3B - FF1T - FG7S--  150285S - Lot # F6S2 - F7X3 - F9F7-FBBZ - FD8T - FE3C-FF1U - FG7T  150290S - Lot # EB7X/G - F6S3 - F890-F98G - FBC0 - FCPU-FDSE - FE3D - FF1V & FH2U  150514S - Lot # EA0T/G - F6W9 - F7Z1-F8EB   FAXQ - FCGX-FEHH   FEXD - FG1C   150516S - Lot # F6WA - F7Z2 - F8EC-FAY4   FCGY - FEHJ-FEXE - FG1D",
      "more_code_info": ""
    }
  ]
}