  "results": [
    {
      "status": "Ongoing",
      "city": "Morrisville",
      "state": "NC",
      "country": "United States",
      "classification": "Class I",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "98793",
      "recalling_firm": "ARROW INTERNATIONAL, LLC",
      "address_1": "3015 Carrington Mill Blvd",
      "address_2": "",
      "postal_code": "27560-5437",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "US Nationwide distribution including in the states of VA, NY, UT, SC, LA, MN, PA, AZ, CA, MI, OH, FL, CT, KS, IL, TX, WI, GA, NC, MD, OR, AK, NH, IA, ND, OK, NM, AL, MA, KY, WA, AR, CO, IN, ME, TN, WY, NJ, SD, MS, MO, MT, DE, ID, NE, WV, RI, VT, NV, HI, DC, PR.",
      "recall_number": "Z-2379-2026",
      "product_description": "Description/REF: PI JACC KIT: 2L 5.5 FR X 15 CM CG+/ASK-41552-LTAC; PI JACC KIT: 3L 6 FR X 20 CM CG+/ASK-42063-LTAC; AGBA PI JACC KIT: 1-L 4.5 FR X 15 CM/CDC-41541-JX1A; AGBA PI JACC KIT: 2-L 5.5 FR X 15 CM/CDC-41552-JX1A; AGBA PI JACC KIT: 3-L 6 FR X 15 CM/CDC-41563-JX1A; AGBA PI JACC KIT: 1-L 4.5 FR X 20 CM/CDC-42041-JX1A; AGBA PI JACC KIT: 2-L 5.5 FR X 20 CM/CDC-42052-JX1A; AGBA PI JACC KIT: 3-L 6 FR X 20 CM/CDC-42063-JX1A",
      "product_quantity": "1,516",
      "reason_for_recall": "Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.",
      "recall_initiation_date": "20260421",
      "center_classification_date": "20260612",
      "report_date": "20260624",
      "code_info": "REF(Material)/UDI-DI/Lot(Batch): ASK-41552-LTAC/10801902193275/33F24J0142, 33F24H0002;  ASK-42063-LTAC/10801902214925/33F24F1005;  CDC-41541-JX1A/10801902193275/33F25H0768;  CDC-41552-JX1A/10801902193275, 10801902201505/33F25A0185, 33F25E0826, 33F24D0561;  CDC-41563-JX1A/10801902193275/33F25B0150;  CDC-42041-JX1A/10801902193275, 10801902188288/33F25E0751, 33F26C0353, 33F25A0186;  CDC-42052-JX1A/10801902193275/33F25G0312, 33F24J0131;  CDC-42063-JX1A/10801902193275/33F25C0447, 33F25D0516, 33F25E0752, 33F25J0436, 33F25C0370",
      "more_code_info": ""
    }
  ]
}