  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-03-18",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "status": "Ongoing",
      "city": "Northfield",
      "state": "IL",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "92399",
      "recalling_firm": "MEDLINE INDUSTRIES, LP - Northfield",
      "address_1": "3 Lakes Dr",
      "address_2": "N/A",
      "postal_code": "60093-2753",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "Letter",
      "distribution_pattern": "Worldwide distribution - US Nationwide and the countries of Canada, China, Costa Rica, India, Lebanon, Panama, Qatar, Saudi Arabia, Singapore, United Arab Emirates.",
      "recall_number": "Z-2331-2023",
      "product_description": "Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel.  Labeled as the following:     a. ANGIO, Model Number: DYNJ905151A;       b. ANGIO/VENO PACK, Model Number: DYNJ58346A;     c. ANGIOGRAPHIC PACK, Model Number: DYNJ57442C, DYNJ64081A;    d. ANGIOGRAPHY PACK, Model Number: DYNJ65963;       e. ANGIOPLASTY PACK-LF, Model Number: DYNJ64655;       f. ARTHROGRAM TRAY, Model Number: SPEC0232;       g. BASIC CATH/ANGIO, Model Number: DYNJ62591A;       h. BASIC PACK, Model Number: DYNJ39752A;       i. C.I.C.N. ANGIO PACK, Model Number: DYNJ53064B;       j. CATH ANGIO PACK, Model Number: DYNJ64050;       k. DBD-KIT NEURO CAROTID SETUP, Model Number: DYKMBNDL148;       l. DBS PACK-LF, Model Number: DYNJ0878178I;       m. GENERAL ANGIO PACK, Model Number: DYNJ57760A;       n. GHIASSI NEURO ANGIO PACK-LF, Model Number: DYNJ57032C;       o. IR NEURO PACK, Model Number: DYNJ39198L, DYNJ39198N;       p. KIT OR AORTOGRM ANGIOPLAST PHT, Model Number: DYNJ906086A;       q. MAIN BASIC NEURO, Model Number: DYNJ908260;       r. NEURO ACCESSORY PACK, Model Number: DYNJ66790, DYNJ66790A, DYNJ66790B;       s. NEURO CATH PACK, Model Number: DYNJ69129, DYNJ83090;       t. NEURO IR PACK, Model Number: DYNJ35066I, DYNJ35066J, DYNJ60701A, DYNJ60701B, DYNJ60701C;       u. NEURO PACK, Model Number: DYNJ43934A, DYNJ61798D, DYNJ66241, DYNJ66241A, DYNJ66241B, DYNJ66241C, DYNJ66241D, DYNJ68956A, DYNJ68956B;        v. NEURO RADIOLOGY PACK, Model Number: DYNJ51107A, DYNJ59903A, DYNJ59903B;       w. NEURO TRAY, Model Number: DYNJ67075, DYNJ67075A;       x. PACK PERCUTANEOUS ANGIO CHRG, Model Number: DYNJ60112A;       y. PEDI ANGIO PACK-LF, Model Number: PHS41743B;       z. PEDIATRIC CATH ANGIO PACK, Model Number: DYNJ54755C;       aa. RADIOLOGY NEURO DRAPE PAC, Model Number: DYNJ61449;       bb. RO-DIEP PACK, Model Number: DYNJ82393A;",
      "product_quantity": "15,945 kits",
      "reason_for_recall": "Potential for the labeled sterile ultrasound gel component within packs to not meet sterility specifications.",
      "recall_initiation_date": "20230515",
      "center_classification_date": "20230803",
      "report_date": "20230809",
      "code_info": "All lot numbers for the following models and corresponding UPCs distributed from Medline between 04/01/2020 and 04/28/2023:    a. Model Number: DYNJ905151A, UPC Number: 019348981341.   b. Model Number: DYNJ58346A, UPC Number: 019348977463.   c. Model Number: DYNJ57442C, UPC Number: 019348920853; Model Number: DYNJ64081A, UPC Number: 019348927374.   d. Model Number: DYNJ65963, UPC Number: 019348930770.   e. Model Number: DYNJ64655, UPC Number: 019348921040.   f. Model Number: SPEC0232, UPC Number: 088827750741.   g. Model Number: DYNJ62591A, UPC Number: 019348979331.   h. Model Number: DYNJ39752A, UPC Number: 088438990723.   i. Model Number: DYNJ53064B, UPC Number: 019348978916.   j. Model Number: DYNJ64050, UPC Number: 019348978046.   k. Model Number: DYKMBNDL148, UPC Number: 019348947839.   l. Model Number: DYNJ0878178I, UPC Number: 019348956435.   m. Model Number: DYNJ57760A, UPC Number: 019348922023.   n. Model Number: DYNJ57032C, UPC Number: 019348945147.    o. Model Number: DYNJ39198L, UPC Number: 019348956435 Model Number: DYNJ39198N, UPC Number: 019532710200.   p. Model Number: DYNJ906086A, UPC Number: 019348920868.   q. Model Number: DYNJ908260, UPC Number: 019532701744.   r. Model Number: DYNJ66790, UPC Number: 019348938243; Model Number: DYNJ66790A, UPC Number: 019348992247; Model Number: DYNJ66790B, UPC Number: 019532709926.   s. Model Number: DYNJ69129, UPC Number: 019348989241; Model Number: DYNJ83090, UPC Number: 019532723093.   t. Model Number: DYNJ35066I, UPC Number: 019348956435; Model Number: DYNJ35066J, UPC Number: 019532709107; Model Number: DYNJ60701A, UPC Number: 019348969378; Model Number: DYNJ60701B, UPC Number: 019348987733; Model Number: DYNJ60701C, UPC Number: 019532703379.   u. Model Number: DYNJ43934A, UPC Number: 019348973360; Model Number: DYNJ61798D, UPC Number: 019348999263; Model Number: DYNJ66241, UPC Number: 019348932296; Model Number: DYNJ66241A, UPC Number: 019348993803; Model Number: DYNJ66241B, UPC Number: 019532705348; Model Number: DYNJ66241C, UPC Number: 019532709685; Model Number: DYNJ66241D, UPC Number: 019532713837; Model Number: DYNJ68956A, UPC Number: 019348987629; Model Number: DYNJ68956B, UPC Number: 019532709434.   v. Model Number: DYNJ51107A, UPC Number: 019348971558; Model Number: DYNJ59903A, UPC Number: 019532704286; Model Number: DYNJ59903B, UPC Number: 019532713120.   w. Model Number: DYNJ67075, UPC Number: 019348938847; Model Number: DYNJ67075A, UPC Number: 019532705453.   x. Model Number: DYNJ60112A, UPC Number: 019348924703.   y. Model Number: PHS41743B, UPC Number: 019348978493.   z. Model Number: DYNJ54755C, UPC Number: 019348977837.   aa. Model Number: DYNJ61449, UPC Number: 019348956734.   bb. Model Number: DYNJ82393A, UPC Number: 019532729232."
    }
  ]
}