{
  "meta": {
    "disclaimer": "Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.",
    "terms": "https://open.fda.gov/terms/",
    "license": "https://open.fda.gov/license/",
    "last_updated": "2026-03-18",
    "results": {
      "skip": 0,
      "limit": 1,
      "total": 1
    }
  },
  "results": [
    {
      "status": "Ongoing",
      "city": "Gainesville",
      "state": "FL",
      "country": "United States",
      "classification": "Class II",
      "openfda": {},
      "product_type": "Devices",
      "event_id": "90279",
      "recalling_firm": "Exactech, Inc.",
      "address_1": "2320 Nw 66th Ct",
      "address_2": "",
      "postal_code": "32653-1630",
      "voluntary_mandated": "Voluntary: Firm initiated",
      "initial_firm_notification": "E-Mail",
      "distribution_pattern": "Worldwide distribution: US (nationwide) and OUS (foreign) countries of: ARGENTINA, BRAZIL, CHILE, CHINA, COLOMBIA, ECUADOR, GREECE, GUATEMALA, INDIA, LEBANON PORTUGAL,PUERTO RICO,SPAIN",
      "recall_number": "Z-1727-2022",
      "product_description": "GXL acetabular liners, orthopedic hip implant component.   Product Line Numbers:    a. ACUMATCH +5MM LAT LINER 15 DEG 36MM ID, SIZE H, REF 138-36-08  b. ACUMATCH +5MM LAT LINER 15 DEG 36MM ID, SIZE J, REF 138-36-09  c. ACUMATCH LINER 15 DEG 36MM ID, SIZE H, REF 132-36-08  d. ACUMATCH LINER 15 DEG 36MM ID, SIZE J, REF 132-36-09  e. ACUMATCH LINER 15 DEG 36MM ID, SIZE K, REF 132-36-10",
      "product_quantity": "132 devices",
      "reason_for_recall": "Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear.",
      "recall_initiation_date": "20220811",
      "center_classification_date": "20220909",
      "report_date": "20220921",
      "code_info": "a. REF 138-36-08, GUDID 10885862024787,  Serial Numbers:  638430, 638433, 638451,  638462, 638467;   b. REF 138-36-09, GUDID 10885862024794,  Serial Numbers:  635279, 635281;   c. REF 132-36-08, GUDID 10885862023353,  Serial Numbers:  630606, 630607, 630609, 630610, 630611, 630612, 630613, 632796, 632797, 632799, 632800, 632801, 632802, 632803, 632805, 632806, 632807, 632808, 632809, 632810, 632812, 632813, 632814, 632815, 632817, 632818, 632819, 632822, 632823, 632824, 632826, 632829, 632830, 632832, 632834, 657859, 657861, 657862, 657863, 657865, 657866, 657867, 657868, 657869, 657870, 657871, 657873, 657875, 657876, 657877, 657878, 657880, 657882, 657883, 657885, 657886, 657887, 657888, 657890, 657891, 657892, 1116881, 1116882, 1116883, 1116886, 1116887, 1116888, 1116889, 1116890, 1116892, 1116896, 1116897, 1116899, 1116903, 1116904, 1116905;   d. REF 132-36-09, GUDID 10885862023360,  Serial Numbers:  638946, 638947, 638950, 643861, 643862, 643863, 643864, 643865, 643866, 643867, 643868, 643869, 643870, 643871, 643872, 643874, 643876, 643877, 643878, 643879, 643880, 643881, 643882, 643883, 643884, 645796, 645798, 645799, 645800, 645801, 645802, 645803, 645805, 645806, 645807, 828079, 828082, 828083, 828084, 828085, 828086, 828088, 828089, 828090, 828091, 828092, 1634294, 2754889;   e. REF 132-36-10, GUDID 10885862023377,  Serial Numbers:  632861.",
      "more_code_info": ""
    }
  ]
}